1,058 research outputs found

    Effect of feeding fermentable fibrerich feedstuffs on meat quality with emphasis on chemical and sensory boar taint in entire male and female pigs

    Get PDF
    Skatole, androstenone and other compounds such as indole cause boar taint in entire male pork. However, female pigs also produce skatole and indole. The purpose of this experiment was to minimise boar taint and increase overall impression of sensory quality by feeding entire male and female pigs with fibrerich feedstuffs. The pigs have been fed three organic diets for either 1 or 2 weeks prior to slaughter of which two diets contained different fermentable fibre-rich feedstuffs – 10–13.3% dried chicory roots or 25% blue lupines. These two treatments were compared with pigs fed with an organic control diet for either 1 or 2 weeks prior to slaughter. Lupines significantly reduced skatole in blood and backfat for both genders after 1 week. Moreover, lupines showed negative impact on growth rate and feed conversion whilst chicory showed no significant differences in this respect. However, the indole concentration was significantly lower in chicory than lupine fed pigs. From a sensory perspective, chicory and lupine feeding reduced boar taint since odour and flavour of manure related to skatole and urine associated to androstenone were minimised. The level of boar taint in the entire male pigs was most effectively reduced after 14 days by both fibre-rich feeds while lupine had the largest influence on ‘‘boar” taint reduction in female pigs

    Custom 3D-Printed Implants for Acetabular Reconstruction: Intermediate-Term Functional and Radiographic Results

    Get PDF
    Background:The management of massive acetabular defects at the time of revision hip surgery is challenging. Severe pelvic bone loss and the heterogeneity and quality of the remaining bone stock can compromise the fixation and mechanical stability of the implant.Methods:We reviewed a database of consecutive patients who had undergone acetabular reconstruction with the use of a custom 3D-printed implant with a dual-mobility bearing for the treatment of Paprosky type-3B defects between 2016 and 2019. Functional and radiological outcomes were assessed.Results:A total of 26 patients (17 women and 9 men) with a minimum follow-up of 36 months (median, 53 months; range, 36 to 77 months) were identified. The median age at surgery was 69 years (range, 49 to 90 years), and 4 patients had pelvic discontinuity. The cumulative implant survivorship was 100%. The median Oxford Hip Score improved significantly from 8 (range, 2 to 21) preoperatively to 32 (range, 14 to 47) postoperatively (p = 0.0001). One patient had a transient sciatic nerve palsy, 1 hip dislocated 6 months postoperatively and was managed nonoperatively, and 1 infection recurred. No patient had a fracture. Radiographic evaluation showed bone ingrowth at the bone-implant interface in 24 patients (92%) at ≥12 months of follow-up and showed no evidence of implant loosening or migration at the latest follow-up (3 to 6 years).Conclusions:Excellent functional improvement, implant survivorship, and osseointegration were recorded in the patient cohort. Accurate preoperative planning and the adoption of custom 3D-printed implants showed promising results in complex revision hip surgery.Level of Evidence:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence

    Cysts and low subchondral bone mineral density: are they relevant to cartilage damage?

    Get PDF

    Self-Reported Neurotoxic Symptoms in Hip Arthroplasty Patients With Highly Elevated Blood Cobalt: A Case-Control Study

    Get PDF
    OBJECTIVES: This study aimed to investigate the prevalence of self-reported neurotoxicity and cognitive defects in hip replacement patients with markedly raised blood cobalt. METHODS: Case group comprised 53 patients with metal-on-metal (MoM) implants and a history of blood Co ≥20 μg/L for a median of 3 years (interquartile range, 2-5 years). The control group comprised 53 patients with ceramic-on-ceramic prostheses and blood Co <1 μg/L. Median age was 67 years (interquartile range, 60-74 years). The participants completed the Neurotoxic Symptom Checklist-60, Diabetic Neuropathy Score, Douleur Neuropathique-10, and Systemic Symptom Checklist, and underwent the Mini-Mental State Examination. RESULTS: The MoM and ceramic-on-ceramic groups were compared, the results were as follows: Neurotoxic Symptom Checklist-60 (median): cognitive defects (2.0 versus 1.9; P = 0.002), chest complaints (1.3 versus 1.3; P = 0.042), balance disturbances (1.3 versus 1.0; P < 0.001), sleep disturbances (2.7 versus 2.0; P = 0.004), mood disorders (2.0 versus 1.5; P = 0.001), sensorimotor disorders (1.6 versus 1.2; P < 0.001), physical complaints (2.0 versus 1.4; P = 0.009), fatigue (2.0 versus 1.6; P = 0.001), and total score (108 versus 90; P < 0.001); abnormal Diabetic Neuropathy Score/Douleur Neuropathique-10 (%): 60.3/13.2 versus 24.5/1.9 (P < 0.001/P = 0.028). Systemic Symptom Checklist (in percent): feeling cold (37.7 versus 17; P = 0.01), weight gain (18.9 versus 1.9; P = 0.008), metallic taste (26.4 versus 3.8; P = 0.002), worsening eyesight (37.7 versus 15.1; P = 0.008) and hearing (24.5 versus 7.5; 0.032), ankle swelling (32.1 versus 7.5; P = 0.002), shortness of breath on exertion (9.4 versus 5.7; P = 0.015), and generalized rash (28.3 versus 7.5; P = 0.01); and Mini-Mental State Examination (median): 29 versus 30 (P = 0.017). Patients in the MoM group were aware of their high cobalt levels and displayed a higher tendency to overreport symptoms (P < 0.001), which could have contributed to the higher scores. CONCLUSIONS: Frequency of reporting a number of symptoms was markedly higher in MoM patients, but clinically significant neurotoxicity was not observed (possibly due to the short exposure to elevated cobalt). Patients with repeated blood Co ≥20 μg/L measurements should be questioned about possible systemic health complaints at follow-up

    Medizinische und gesundheitsökonomische Bewertung der Radiochirurgie zur Behandlung von Hirnmetastasen

    Get PDF
    Background: Expressed Sequence Tags (ESTs) are in general used to gain a first insight into gene activities from a species of interest. Subsequently, and typically based on a combination of EST and genome sequences, microarray-based expression analyses are performed for a variety of conditions. In some cases, a multitude of EST and microarray experiments are conducted for one species, covering different tissues, cell states, and cell types. Under these circumstances, the challenge arises to combine results derived from the different expression profiling strategies, with the goal to uncover novel information on the basis of the integrated datasets. Findings: Using our new analysis tool, MediPlEx (MEDIcago truncatula multiPLe EXpression analysis), expression data from EST experiments, oligonucleotide microarrays and Affymetrix GeneChips® can be combined and analyzed, leading to a novel approach to integrated transcriptome analysis. We have validated our tool via the identification of a set of well-characterized AM-specific and AM-induced marker genes, identified by MediPlEx on the basis of in silico and experimental gene expression profiles from roots colonized with AM fungi. Conclusions: MediPlEx offers an integrated analysis pipeline for different sets of expression data generated for the model legume Medicago truncatula. As expected, in silico and experimental gene expression data that cover the same biological condition correlate well. The collection of differentially expressed genes identified via MediPlEx provides a starting point for functional studies in plant mutants

    Detection of incorrect manufacturer labelling of hip components

    Get PDF
    We describe the case of a 53-year-old man who underwent a left metal-on-metal hip resurfacing in 2015. Component size mismatch (CSM) was suspected because of the patient's immediate post-operative mechanical symptoms and high metal ion levels. Surgical notes indicated the appropriate combinations of implants were used. However, we detected a mismatch using computed tomography. Revision was performed and subsequent measurements of explanted components confirmed the mismatch. To our knowledge, this case is the first report of a CT method being used in a patient to pre-operatively identify CSM

    Intramuscular fat in gluteus maximus for different levels of physical activity

    Get PDF
    We aimed to determine if gluteus maximus (GMAX) fat infiltration is associated with different levels of physical activity. Identifying and quantifying differences in the intramuscular fat content of GMAX in subjects with different levels of physical activity can provide a new tool to evaluate hip muscles health. This was a cross-sectional study involving seventy subjects that underwent Dixon MRI of the pelvis. The individuals were divided into four groups by levels of physical activity, from low to high: inactive patients due to hip pain; and low, medium and high physical activity groups of healthy subjects (HS) based on hours of exercise per week. We estimated the GMAX intramuscular fat content for each subject using automated measurements of fat fraction (FF) from Dixon images. The GMAX volume and lean volume were also measured and normalized by lean body mass. The effects of body mass index (BMI) and age were included in the statistical analysis. The patient group had a significantly higher FF than the three groups of HS (median values of 26.2%, 17.8%, 16.7% and 13.7% respectively, p < 0.001). The normalized lean volume was significantly larger in the high activity group compared to all the other groups (p < 0.001, p = 0.002 and p = 0.02). Employing a hierarchical linear regression analysis, we found that hip pain, low physical activity, female gender and high BMI were statistically significant predictors of increased GMAX fat infiltration

    Uncemented femoral stem orientation and position in total hip arthroplasty: A CT study

    Get PDF
    In total hip arthroplasty (THA), accurate positioning of components is important for the functionality and long life of the implant. Femoral component version has been underinvestigated when compared with the acetabular cup. Accurate prediction of the femoral version on the preoperative plan is particularly important because a well-fitting uncemented stem will, by definition, press-fit into a version that is dictated by the anatomy of the proximal femur. A better understanding of this has recently become an unmet need because of the increased use of uncemented stems and of preoperative image-based planning. We present the first, three-dimensional (3D) comparison between the planned and achieved orientation and position of the femoral components in THA. We propose a comparison method that uses the 3D models of a, computed tomography-generated (CT-generated), preoperative plan and a postoperative CT to obtain the discrepancy in the six possible degrees of freedom. We ran a prospective study (level 2 evidence) of 30 patients undergoing uncemented THA to quantify the discrepancy between planned and achieved femoral stem orientation and position. The discrepancy was low for femoral stem vertical position and leg length, and varus-valgus and anterior-posterior orientation. The discrepancy was higher for femoral version with a mean (±SD) of -1.5 ± 7.8 deg. Surgeons should be aware of the variability of the eventual position of uncemented stems in THA and acknowledge the risk of achieving a less-than-optimal femoral version, different from the preoperative 3D CT plan

    Method for the location of primary wear scars from retrieved metal on metal hip replacements

    Get PDF
    Retrieved metal-on-metal acetabular cups are valuable resources in investigating the wear behaviour of failed hip implants, but adequate methods to do so are lacking. To further contribute to addressing this issue, we developed a method to detect the in vivo location of the primary wear scar of an explanted cup

    Reference values for volume, fat content and shape of the hip abductor muscles in healthy individuals from Dixon MRI

    Get PDF
    Healthy hip abductor muscles are a good indicator of a healthy hip and an active lifestyle, as they are greatly involved in human daily activities. Fatty infiltration and muscle atrophy are associated with loss of strength, loss of mobility and hip disease. However, these variables have not been widely studied in this muscle group. We aimed to characterize the hip abductor muscles in a group of healthy individuals to establish reference values for volume, intramuscular fat content and shape of this muscle group. To achieve this, we executed a cross-sectional study using Dixon MRI scans of 51 healthy subjects. We used an automated segmentation method to label GMAX, GMED, GMIN and TFL muscles, measured normalized volume (NV) using lean body mass, fat fraction (FF) and lean muscle volume for each subject and computed non-parametric statistics for each variable grouped by sex and age. We measured these variables for each axial slice and created cross-sectional area and FF axial profiles for each muscle. Finally, we generated sex-specific atlases with FF statistical images. We measured median (IQR) NV values of 12.6 (10.8-13.8), 6.3 (5.6-6.7), 1.6 (1.4-1.7) and 0.8 (0.6-1.0) cm3/kg for GMAX, GMED, GMIN and TFL, and median (IQR) FF values of 12.3 (10.1-15.9)%, 9.8 (8.6-11.2)%, 10.0 (9.0-12.0)% and 10.2 (7.8-13.5)% respectively. FF values were significantly higher for females for the four muscles (p < 0.01), but there were no significant differences between the two age groups. When comparing individual muscles, we observed a significantly higher FF in GMAX than in the other muscles. The reported novel reference values and axial profiles for volume and FF of the hip abductors, together with male and female atlases, are tools that could potentially help to quantify and detect early the deteriorating effects of hip disease or sarcopenia
    corecore