1,191 research outputs found

    Backbone rigidity and static presentation of guanidinium groups increases cellular uptake of arginine-rich cell-penetrating peptides

    Get PDF
    In addition to endocytosis-mediated cellular uptake, hydrophilic cell-penetrating peptides are able to traverse biological membranes in a non-endocytic mode termed transduction, resulting in immediate bioavailability. Here we analysed structural requirements for the non-endocytic uptake mode of arginine-rich cell-penetrating peptides, by a combination of live-cell microscopy, molecular dynamics simulations and analytical ultracentrifugation. We demonstrate that the transduction efficiency of arginine-rich peptides increases with higher peptide structural rigidity. Consequently, cyclic arginine-rich cell-penetrating peptides showed enhanced cellular uptake kinetics relative to their linear and more flexible counterpart. We propose that guanidinium groups are forced into maximally distant positions by cyclization. This orientation increases membrane contacts leading to enhanced cell penetration

    Vision-based real-time position control of a semi-automated system for robot-assisted joint fracture surgery

    Get PDF
    Purpose: Joint fracture surgery quality can be improved by robotic system with high-accuracy and high-repeatability fracture fragment manipulation. A new real-time vision-based system for fragment manipulation during robot-assisted fracture surgery was developed and tested. Methods: The control strategy was accomplished by merging fast open-loop control with vision-based control. This two-phase process is designed to eliminate the open-loop positioning errors by closing the control loop using visual feedback provided by an optical tracking system. Evaluation of the control system accuracy was performed using robot positioning trials, and fracture reduction accuracy was tested in trials on ex vivo porcine model.Results: The system resulted in high fracture reduction reliability with a reduction accuracy of 0.09mm (translations) and of (Formula presented.) (rotations), maximum observed errors in the order of 0.12mm (translations) and of (Formula presented.) (rotations), and a reduction repeatability of 0.02mm and (Formula presented.). Conclusions: The proposed vision-based system was shown to be effective and suitable for real joint fracture surgical procedures, contributing a potential improvement of their quality

    Optimal functional outcome measures for assessing treatment for Dupuytren's disease: A systematic review and recommendations for future practice

    Get PDF
    This article is available through the Brunel Open Access Publishing Fund. Copyright © 2013 Ball et al.; licensee BioMed Central Ltd.Background: Dupuytren's disease of the hand is a common condition affecting the palmar fascia, resulting in progressive flexion deformities of the digits and hence limitation of hand function. The optimal treatment remains unclear as outcomes studies have used a variety of measures for assessment. Methods: A literature search was performed for all publications describing surgical treatment, percutaneous needle aponeurotomy or collagenase injection for primary or recurrent Dupuytren’s disease where outcomes had been monitored using functional measures. Results: Ninety-one studies met the inclusion criteria. Twenty-two studies reported outcomes using patient reported outcome measures (PROMs) ranging from validated questionnaires to self-reported measures for return to work and self-rated disability. The Disability of Arm, Shoulder and Hand (DASH) score was the most utilised patient-reported function measure (n=11). Patient satisfaction was reported by eighteen studies but no single method was used consistently. Range of movement was the most frequent physical measure and was reported in all 91 studies. However, the methods of measurement and reporting varied, with seventeen different techniques being used. Other physical measures included grip and pinch strength and sensibility, again with variations in measurement protocols. The mean follow-up time ranged from 2 weeks to 17 years. Conclusions: There is little consistency in the reporting of outcomes for interventions in patients with Dupuytren’s disease, making it impossible to compare the efficacy of different treatment modalities. Although there are limitations to the existing generic patient reported outcomes measures, a combination of these together with a disease-specific questionnaire, and physical measures of active and passive individual joint Range of movement (ROM), grip and sensibility using standardised protocols should be used for future outcomes studies. As Dupuytren’s disease tends to recur following treatment as well as extend to involve other areas of the hand, follow-up times should be standardised and designed to capture both short and long term outcomes

    Evaluating Retinal Function in Age-Related Maculopathy with the ERG Photostress Test

    Get PDF
    PURPOSE. To evaluate the diagnostic potential of the electroretinogram (ERG) photostress test and the focal cone ERG in age-related maculopathy (ARM). METHODS. The cohort comprised 31 patients with ARM and 27 age-matched control subjects. The ERG photostress test was used to monitor cone adaptation after intense light adaptation. Focal 41- and 5-Hz cone ERGs were recorded monocularly (central 20°) to assess steady state retinal function. Univariate analysis identified electrophysiological parameters that differed between groups, and receiver operating characteristic (ROC) curves were constructed to assess their diagnostic potential. Logistic regression analysis determined the diagnostic potential of a model incorporating several independent predictors of ARM. RESULTS. The rate of recovery of the ERG photostress test was reduced (recovery was slower) in subjects with ARM. The parameter exhibited good diagnostic potential (P = 0.002, area under ROC curve = 0.74). The implicit times of the 5-Hz (a-wave, P = 0.002; b-wave, P < 0.001) and the 41-Hz (P < 0.001) focal cone ERGs were increased, and the 41-Hz focal cone ERG amplitude (P = 0.003) and focal to full-field amplitude ratio (P = 0.001) were reduced in the ARM group. Logistic regression analysis identified three independent predictors of ARM, including the rate of recovery of the ERG photostress test. CONCLUSIONS. Early ARM has a marked effect on the kinetics of cone adaptation. The clinical application of the ERG photostress test increases the sensitivity and specificity of a model for the diagnosis of ARM. Improved assessment of the functional integrity of the central retina will facilitate early diagnosis and evaluation of therapeutic interventions

    Extravascular Lung Water Correlates Multiorgan Dysfunction Syndrome and Mortality in Sepsis

    Get PDF
    BACKGROUND: This study was designated to investigate whether increased extravascular lung water index (EVLWI) may correlate multiple organ dysfunction syndrome (MODS) and mortality in sepsis. METHODS: We designed a prospective cohort study in an intensive care unit of a tertiary care hospital. Sixty-seven patients with severe sepsis were included. Data were used to determine an association between EVLWI and the development of MODS and mortality. These connections were determined by the multiple logistic regression, plotting the receiver operating characteristic (ROC) curve and by Spearman test. RESULTS: EVLWI levels were higher in MODS patients on day 1 (median (IQR), 18(12.8-23.9) ml/kg, n = 38, p<0.0001) than in those without (median (IQR), 12.4 (7.9-16.3) ml/kg, n = 29) and day 3 (median (IQR), 17.8 (11.2-22.8) ml/kg, n = 29, p = 0.004) than in those without (median (IQR), 12.4 (8.0-16.3) ml/kg, n = 29). EVLWI was used as an independent predictor of the development of MODS (odds ratio, 1.6; p = 0.005; 95% confidence interval, 1.2∼2.2) during ICU stay. The area under the ROC curve showed that EVLWI levels could predict MODS (0.866) and mortality (0.881) during ICU stay. Meanwhile, the higher of SOFA score, the more EVLWI was found on day 1 (r = 0.7041, p<0.0001) and day 3 (r = 0.7732, p<0.0001). CONCLUSIONS: Increased EVLWI levels correlates development of MODS and mortality during the patients' ICU stay. Further more, the potential of novel treatment in severe sepsis with lung injury may develop

    Dislocations and vortices in pair density wave superconductors

    Full text link
    With the ground breaking work of the Fulde, Ferell, Larkin, and Ovchinnikov (FFLO), it was realized that superconducting order can also break translational invariance; leading to a phase in which the Cooper pairs develop a coherent periodic spatially oscillating structure. Such pair density wave (PDW) superconductivity has become relevant in a diverse range of systems, including cuprates, organic superconductors, heavy fermion superconductors, cold atoms, and high density quark matter. Here we show that, in addition to charge density wave (CDW) order, there are PDW ground states that induce spin density wave (SDW) order when there is no applied magnetic field. Furthermore, we show that PDW phases support topological defects that combine dislocations in the induced CDW/SDW order with a fractional vortex in the usual superconducting order. These defects provide a mechanism for fluctuation driven non-superconducting CDW/SDW phases and conventional vortices with CDW/SDW order in the core.Comment: 6 pages,1 figure, 1 tabl

    Neutron Majorana mass from exotic instantons

    Get PDF
    We show how a Majorana mass for the Neutron could result from non-perturbative quantum gravity effects peculiar to string theory. In particular, "exotic instantons" in un-oriented string compactifications with D-branes extending the (supersymmetric) standard model could indirectly produce an effective operator delta{m} n^t n+h.c. In a specific model with an extra vector-like pair of `quarks', acquiring a large mass proportional to the string mass scale (exponentially suppressed by a function of the string moduli fields), delta{m} can turn out to be as low as 10^{-24}-10^{-25} eV. The induced neutron-antineutron oscillations could take place with a time scale tau_{n\bar{n}} > 10^8 s, that could be tested by the next generation of experiments. On the other hand, proton decay and FCNC's are automatically strongly suppressed and are compatible with the current experimental limits. Depending on the number of brane intersections, the model may also lead to the generation of Majorana masses for R-handed neutrini. Our proposal could also suggest neutron-neutralino or neutron-axino oscillations, with implications in UCN, Dark Matter Direct Detection, UHECR and Neutron-Antineutron oscillations. This suggests to improve the limits on neutron-antineutron oscillations, as a possible test of string theory and quantum gravity.Comment: 35 pages, 11 figures. More comments on neutron-neutralino mixin

    Implications of a high-definition multileaf collimator (HD-MLC) on treatment planning techniques for stereotactic body radiation therapy (SBRT): a planning study

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>To assess the impact of two multileaf collimator (MLC) systems (2.5 and 5 mm leaf widths) on three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and dynamic conformal arc techniques for stereotactic body radiation therapy (SBRT) of liver and lung lesions.</p> <p>Methods</p> <p>Twenty-nine SBRT plans of primary liver (n = 11) and lung (n = 18) tumors were the basis of this study. Five-millimeter leaf width 120-leaf Varian Millennium (M120) MLC-based plans served as reference, and were designed using static conformal beams (3DCRT), sliding-window intensity-modulated beams (IMRT), or dynamic conformal arcs (DCA). Reference plans were either re-optimized or recomputed, with identical planning parameters, for a 2.5-mm width 120-leaf BrainLAB/Varian high-definition (HD120) MLC system. Dose computation was based on the anisotropic analytical algorithm (AAA, Varian Medical Systems) with tissue heterogeneity taken into account. Each plan was normalized such that 100% of the prescription dose covered 95% of the planning target volume (PTV). Isodose distributions and dose-volume histograms (DVHs) were computed and plans were evaluated with respect to target coverage criteria, normal tissue sparing criteria, as well as treatment efficiency.</p> <p>Results</p> <p>Dosimetric differences achieved using M120 and the HD120 MLC planning were generally small. Dose conformality improved in 51.7%, 62.1% and 55.2% of the IMRT, 3DCRT and DCA cases, respectively, with use of the HD120 MLC system. Dose heterogeneity increased in 75.9%, 51.7%, and 55.2% of the IMRT, 3DCRT and DCA cases, respectively, with use of the HD120 MLC system. DVH curves demonstrated a decreased volume of normal tissue irradiated to the lower (90%, 50% and 25%) isodose levels with the HD120 MLC.</p> <p>Conclusion</p> <p>Data derived from the present comparative assessment suggest dosimetric merit of the high definition MLC system over the millennium MLC system. However, the clinical significance of these results warrants further investigation in order to determine whether the observed dosimetric advantages translate into outcome improvements.</p
    • …
    corecore