41,015 research outputs found

    Particle parameter analyzing system

    Get PDF
    An X-Y plotter circuit apparatus is described which displays an input pulse representing particle parameter information, that would ordinarily appear on the screen of an oscilloscope as a rectangular pulse, as a single dot positioned on the screen where the upper right hand corner of the input pulse would have appeared. If another event occurs, and it is desired to display this event, the apparatus is provided to replace the dot with a short horizontal line

    Thermo electronic laser energy conversion

    Get PDF
    The thermo electronic laser energy converter (TELEC) is described and compared to the Waymouth converter and the conventional thermionic converter. The electrical output characteristics and efficiency of TELEC operation are calculated for a variety of design variables. Calculations and results are briefly outlined. It is shown that the TELEC concept can potentially convert 25 to 50 percent of incident laser radiation into electric power at high power densities and high waste heat rejection temperatures

    A solid-state low-noise preamplifier

    Get PDF
    Solid state low noise preamplifier for particle detector of electrostatic accelerator syste

    A global protocol for monitoring of coral bleaching

    Get PDF
    Coral bleaching and subsequent mortality represent a major threat to the future health and productivity of coral reefs. However a lack of reliable data on occurrence, severity and other characteristics of bleaching events hampers research on the causes and consequences of this important phenomenon. This article describes a global protocol for monitoring coral bleaching events, which addresses this problem and can be used by people with different levels of expertise and resources

    The plasmatron: Advanced mode thermionic energy conversion

    Get PDF
    A theory of the plasmatron was developed. Also, a wide range of measurements were obtained with two versatile, research devices. To gain insight into plasmatron performance, the experimental results are compared with calculations based on the theoretical model of plasmatron operation. Results are presented which show that the plasma arc drop of the conventional arc (ignited) mode converter can be suppressed by use of an auxiliary ion source. The improved performance, however, is presently limited to low current densities because of voltage losses due to plasma resistance. This resistance loss could be suppressed by an increase in the plasma electron temperature or a decrease in spacing. Plasmatron performance characteristics for both argon and cesium are reported. The argon plasmatron has superior performance. Results are also presented for magnetic cutoff effects and for current distributing effects. These are shown to be important factors for the design of practical devices

    A global protocol for monitoring of coral bleaching

    Get PDF
    Coral bleaching and subsequent mortality represent a major threat to the future health and productivity of coral reefs. However a lack of reliable data on occurrence, severity and other characteristics of bleaching events hampers research on the causes and consequences of this important phenomenon. This article describes a global protocol for monitoring coral bleaching events, which addresses this problem and can be used by people with different levels of expertise and resources.Coral reefs, Bleaching, Mortality, Monitoring

    Comment on "Formation of primordial black holes by cosmic strings"

    Full text link
    We show that in a pioneering paper by Polnarev and Zembowicz, some conclusions concerning the characteristics of the Turok-strings are generally not correct. In addition we show that the probability of string collapse given there, is off by a large prefactor (~1000).Comment: 5 pages, LaTeX and 1 figure, postscript. To appear in PR

    Tunable BODIPY derivatives amenable to "click" and peptide chemistry

    Get PDF
    Novel azido- and amino- functionalised fluorescent probes based on the BODIPY framework have been developed. The probes can be easily and cheaply synthesised, exhibit the highly desirable BODIPY fluorescent properties, and are amenable to “click” and peptide chemistry methodologies. These probes provide a stable and readily available tool amenable for the visualisation of both solution and solid supported events
    corecore