208 research outputs found

    Mesenteric panniculitis: a clinical conundrum

    Get PDF
    Mesenteric panniculitis is encountered frequently during abdominopelvic CT scanning, often as an incidental finding. The observation is problematic because an association with malignancy has been raised in the literature. This review will describe the CT appearances and examine the available evidence regarding the significance of this finding.Ultimately, the literature remains unclear regarding how these patients should be managed, if at all

    Computer-assisted polyp matching between optical colonoscopy and CT colonography: a phantom study

    Full text link
    Potentially precancerous polyps detected with CT colonography (CTC) need to be removed subsequently, using an optical colonoscope (OC). Due to large colonic deformations induced by the colonoscope, even very experienced colonoscopists find it difficult to pinpoint the exact location of the colonoscope tip in relation to polyps reported on CTC. This can cause unduly prolonged OC examinations that are stressful for the patient, colonoscopist and supporting staff. We developed a method, based on monocular 3D reconstruction from OC images, that automatically matches polyps observed in OC with polyps reported on prior CTC. A matching cost is computed, using rigid point-based registration between surface point clouds extracted from both modalities. A 3D printed and painted phantom of a 25 cm long transverse colon segment was used to validate the method on two medium sized polyps. Results indicate that the matching cost is smaller at the correct corresponding polyp between OC and CTC: the value is 3.9 times higher at the incorrect polyp, comparing the correct match between polyps to the incorrect match. Furthermore, we evaluate the matching of the reconstructed polyp from OC with other colonic endoluminal surface structures such as haustral folds and show that there is a minimum at the correct polyp from CTC. Automated matching between polyps observed at OC and prior CTC would facilitate the biopsy or removal of true-positive pathology or exclusion of false-positive CTC findings, and would reduce colonoscopy false-negative (missed) polyps. Ultimately, such a method might reduce healthcare costs, patient inconvenience and discomfort.Comment: This paper was presented at the SPIE Medical Imaging 2014 conferenc

    Meta-research: How many diagnostic or prognostic models published in radiological journals are evaluated externally?

    Get PDF
    OBJECTIVES: Prognostic and diagnostic models must work in their intended clinical setting, proven via "external evaluation", preferably by authors uninvolved with model development. By systematic review, we determined the proportion of models published in high-impact radiological journals that are evaluated subsequently. METHODS: We hand-searched three radiological journals for multivariable diagnostic/prognostic models 2013-2015 inclusive, developed using regression. We assessed completeness of data presentation to allow subsequent external evaluation. We then searched literature to August 2022 to identify external evaluations of these index models. RESULTS: We identified 98 index studies (73 prognostic; 25 diagnostic) describing 145 models. Only 15 (15%) index studies presented an evaluation (two external). No model was updated. Only 20 (20%) studies presented a model equation. Just 7 (15%) studies developing Cox models presented a risk table, and just 4 (9%) presented the baseline hazard. Two (4%) studies developing non-Cox models presented the intercept. Just 20 (20%) articles presented a Kaplan-Meier curve of the final model. The 98 index studies attracted 4224 citations (including 559 self-citations), median 28 per study. We identified just six (6%) subsequent external evaluations of an index model, five of which were external evaluations by researchers uninvolved with model development, and from a different institution. CONCLUSIONS: Very few prognostic or diagnostic models published in radiological literature are evaluated externally, suggesting wasted research effort and resources. Authors' published models should present data sufficient to allow external evaluation by others. To achieve clinical utility, researchers should concentrate on model evaluation and updating rather than continual redevelopment. CLINICAL RELEVANCE STATEMENT: The large majority of prognostic and diagnostic models published in high-impact radiological journals are never evaluated. It would be more efficient for researchers to evaluate existing models rather than practice continual redevelopment. KEY POINTS: • Systematic review of highly cited radiological literature identified few diagnostic or prognostic models that were evaluated subsequently by researchers uninvolved with the original model. • Published radiological models frequently omit important information necessary for others to perform an external evaluation: Only 20% of studies presented a model equation or nomogram. • A large proportion of research citing published models focuses on redevelopment and ignores evaluation and updating, which would be a more efficient use of research resources

    Prognostic factors to identify resolution of small bowel obstruction without need for operative management: systematic review

    Get PDF
    OBJECTIVES: To identify imaging, clinical, and laboratory variables potentially prognostic for surgical management of small bowel obstruction. METHODS: Two researchers systematically reviewed indexed literature 2001-2021 inclusive for imaging, clinical, and laboratory variables potentially predictive of surgical management of small bowl obstruction and/or ischaemia at surgery, where performed. Risk of bias was assessed. Contingency tables for variables reported in at least 5 studies were extracted and meta-analysed to identify strong evidence of association with clinical outcomes, across studies. RESULTS: Thirty-one studies were ultimately included, reporting 4638 patients (44 to 313 per study). 11 (35%) studies raised no risk of bias concerns. CT was the modality reported most (29 studies, 94%). Meta-analysis of 21 predictors identified 5 strongly associated with surgical intervention, 3 derived from CT (peritoneal free fluid, odds ratio [OR] 3.24, 95%CI 2.45 to 4.29; high grade obstruction, OR 3.58, 95%CI 2.46 to 5.20; mesenteric inflammation, OR 2.61, 95%CI 1.94 to 3.50; abdominal distension, OR 2.43, 95%CI 1.34 to 4.42; peritonism, OR 3.97, 95%CI 2.67 to 5.90) and one with conservative management (previous abdominopelvic surgery, OR 0.58, 95%CI 0.40 to 0.85). Meta-analysis of 10 predictors identified 3 strongly associated with ischaemia at surgery, 2 derived from CT (peritoneal free fluid, OR 3.49, 95%CI 2.28 to 5.35; bowel thickening, OR 3.26 95%CI 1.91 to 5.55; white cell count, OR 4.76, 95%CI 2.71 to 8.36). CONCLUSIONS: Systematic review of patients with small bowel obstruction identified four imaging, three clinical, and one laboratory predictors associated strongly with surgical intervention and/or ischaemia at surgery. CLINICAL RELEVANCE STATEMENT: Via systematic review and meta-analysis, we identified imaging, clinical, and laboratory predictors strongly associated with surgical management of small bowel obstruction and/or ischaemia. Multivariable model development to guide management should incorporate these since they display strong evidence of potential utility. KEY POINTS: • While multivariable models incorporating clinical, laboratory, and imaging factors could predict surgical management of small bowel obstruction, none are used widely. • Via systematic review and meta-analysis we identified imaging, clinical, and laboratory variables strongly associated with surgical management and/or ischaemia at surgery. • Development of multivariable models to guide management should incorporate these predictors, notably CT scanning, since they display strong evidence of potential utility

    Two-dimensional Endoanal Ultrasound Scan Correlates with External Anal Sphincter Structure and Function, but not with Puborectalis

    Get PDF
    AbstractBackgroundTo investigate the relevance of two-dimensional (2D) endoanal ultrasonic (EAUS) assessment of anal sphincter and puborectalis morphology by comparison to functional measures derived from patient symptoms and anorectal physiology.MethodsThirty women (mean age 44 years, mean parity 2) with anal incontinence underwent 2D EAUS, anorectal pull-through manometry, anorectal electosensitivity and sensation to rectal distension, pelvic floor dynamometry, and completed Wexner incontinence scores. EAUS images were reported blind to physiological assessments by a single experienced observer. The external and internal sphincters, and puborectalis were measured and scored for integrity and atrophy, and correlated with symptom load (Wexner score) and physiological data.ResultsThe mean Wexner score was 10 (range 1–20). The puborectalis could not be accurately measured in 12 patients (44%) on EAUS. Anal squeeze pressure correlated with integrity of the external sphincter (r = −0.4, p = 0.02) but not integrity or atrophy of the puborectalis. There were no other significant correlations between EAUS features and patient symptom load or anorectal physiology (r range, −0.42–0.26, p > 0.05).ConclusionTwo-dimensional EAUS can define sphincter integrity, has a limited role for assessment of muscular quality but is not useful for assessment of the puborectalis

    Are preoperative CT variables associated with the success or failure of subsequent ventral hernia repair: nested case-control study

    Get PDF
    OBJECTIVES: Systematic review of CT measurements to predict the success or failure of subsequent ventral hernia repair has found limited data available in the indexed literature. To rectify this, we investigated multiple preoperative CT metrics to identify if any were associated with postoperative reherniation. METHODS: Following ethical permission, we identified patients who had undergone ventral hernia repair and had preoperative CT scanning available. Two radiologists made multiple measurements of the hernia and abdominal musculature from these scans, including loss of domain. Patients were divided subsequently into two groups, defined by hernia recurrence at 1-year subsequent to surgery. Hypothesis testing investigated any differences between CT measurements from each group. RESULTS: One hundred eighty-eight patients (95 male) were identified, 34 (18%) whose hernia had recurred by 1-year. Only three of 34 CT measurements were significantly different when patients whose hernia had recurred were compared to those who had not; these significant findings were assumed contingent on multiple testing. In particular, preoperative hernia volume (recurrence 155.3 cc [IQR 355.65] vs. no recurrence 78.2 [IQR 303.52], p = 0.26) nor loss of domain, whether calculated using the Tanaka (recurrence 0.02 [0.04] vs. no recurrence 0.009 [0.04], p = 0.33) or Sabbagh (recurrence 0.019 [0.05] vs. no recurrence 0.009 [0.04], p = 0.25) methods, differed between significantly between groups. CONCLUSIONS: Preoperative CT measurements of ventral hernia morphology, including loss of domain, appear unrelated to postoperative recurrence. It is likely that the importance of such measurements to predict recurrence is outweighed by other patient factors and surgical reconstruction technique. KEY POINTS: • Preoperative CT scanning is often performed for ventral hernia but systematic review revealed little data regarding whether CT variables predict postoperative reherniation. • We found that the large majority of CT measurements, including loss of domain, did not differ significantly between patients whose hernia did and did not recur. • It is likely that the importance of CT measurements to predict recurrence is outweighed by other patient factors and surgical reconstruction technique

    The second ESGAR consensus statement on CT colonography

    Get PDF
    To update quality standards for CT colonography based on consensus among opinion leaders within the European Society of Gastrointestinal and Abdominal Radiology (ESGAR). A multinational European panel of nine members of the ESGAR CT colonography Working Group (representing six EU countries) used a modified Delphi process to rate their level of agreement on a variety of statements pertaining to the acquisition, interpretation and implementation of CT colonography. Four Delphi rounds were conducted, each at 2 months interval. The panel elaborated 86 statements. In the final round the panelists achieved complete consensus in 71 of 86 statements (82 %). Categories including the highest proportion of statements with excellent Cronbach's internal reliability were colon distension, scan parameters, use of intravenous contrast agents, general guidelines on patient preparation, role of CAD and lesion measurement. Lower internal reliability was achieved for the use of a rectal tube, spasmolytics, decubitus positioning and number of CT data acquisitions, faecal tagging, 2D vs. 3D reading, and reporting. The recommendations of the consensus should be useful for both the radiologist who is starting a CTC service and for those who have already implemented the technique but whose practice may need updating

    Design of a multicentre randomized trial to evaluate CT colonography versus colonoscopy or barium enema for diagnosis of colonic cancer in older symptomatic patients: The SIGGAR study

    Get PDF
    Background and Aims: The standard whole-colon tests used to investigate patients with symptoms of colorectal cancer are barium enema and colonoscopy. Colonoscopy is the reference test but is technically difficult, resource intensive, and associated with adverse events, especially in the elderly. Barium enema is safer but has reduced sensitivity for cancer. CT colonography ("virtual colonoscopy") is a newer alternative that may combine high sensitivity for cancer with safety and patient acceptability. The SIGGAR trial aims to determine the diagnostic efficacy, acceptability, and economic costs associated with this new technology.Methods: The SIGGAR trial is a multi-centre randomised comparison of CT colonography versus standard investigation ( barium enema or colonoscopy), the latter determined by individual clinician preference. Diagnostic efficacy for colorectal cancer and colonic polyps measuring 1 cm or larger will be determined, as will the physical and psychological morbidity associated with each diagnostic test, the latter via questionnaires developed from qualitative interviews. The economic costs of making or excluding a diagnosis will be determined for each diagnostic test and information from the trial and other data from the literature will be used to populate models framed to summarise the health effects and costs of alternative approaches to detection of significant colonic neoplasia in patients of different ages, prior risks and preferences. This analysis will focus particularly on the frequency, clinical relevance, costs, and psychological and physical morbidity associated with detection of extracolonic lesions by CT colonography.Results: Recruitment commenced in March 2004 and at the time of writing ( July 2007) 5025 patients have been randomised. A lower than expected prevalence of end-points in the barium enema sub-trial has caused an increase in sample size. In addition to the study protocol, we describe our approach to recruitment, notably the benefits of extensive piloting, the use of a sham-randomisation procedure, which was employed to determine whether centres interested in participating were likely to be effective in practice, and the provision of funding for dedicated sessions for a research nurse at each centre to devote specifically to this trial

    Towards a framework for analysis of eye-tracking studies in the three dimensional environment: a study of visual search by experienced readers of endoluminal CT colonography.

    Get PDF
    Objective: Eye tracking in three dimensions is novel, but established descriptors derived from two-dimensional (2D) studies are not transferable. We aimed to develop metrics suitable for statistical comparison of eye-tracking data obtained from readers of three-dimensional (3D) “virtual” medical imaging, using CT colonography (CTC) as a typical example. Methods: Ten experienced radiologists were eye tracked while observing eight 3D endoluminal CTC videos. Sub-sequently, we developed metrics that described their visual search patterns based on concepts derived from 2D gaze studies. Statistical methods were developed to allow analysis of the metrics. Results: Eye tracking was possible for all readers. Visual dwell on the moving region of interest (ROI) was defined as pursuit of the moving object across multiple frames. Using this concept of pursuit, five categories of metrics were defined that allowed characterization of reader gaze behaviour. These were time to first pursuit, identi-fication and assessment time, pursuit duration, ROI size and pursuit frequency. Additional subcategories allowed us to further characterize visual search between readers in the test population. Conclusion: We propose metrics for the characterization of visual search of 3D moving medical images. These metrics can be used to compare readers’ visual search patterns and provide a reproducible framework for the analysis of gaze tracking in the 3D environment. Advances in knowledge: This article describes a novel set of metrics that can be used to describe gaze behaviour when eye tracking readers during interpretation of 3D medical images. These metrics build on those established for 2D eye tracking and are applicable to increasingly common 3D medical image displays

    Quantifying public preferences for different bowel preparation options prior to screening CT colonography: a discrete choice experiment

    Get PDF
    Objectives: CT colonography (CTC) may be an acceptable test for colorectal cancer screening but bowel preparation can be a barrier to uptake. This study tested the hypothesis that prospective screening invitees would prefer full-laxative preparation with higher sensitivity and specificity for polyps, despite greater burden, over less burdensome reduced-laxative or non-laxative alternatives with lower sensitivity and specificity. Design: Discrete choice experiment. Setting: Online, web-based survey. Participants: 2819 adults (45–54 years) from the UK responded to an online invitation to take part in a cancer screening study. Quota sampling ensured that the sample reflected key demographics of the target population and had no relevant bowel disease or medical qualifications. The analysis comprised 607 participants. Interventions: After receiving information about screening and CTC, participants completed 3–4 choice scenarios. Scenarios showed two hypothetical forms of CTC with different permutations of three attributes: preparation, sensitivity and specificity for polyps. Primary outcome measures: Participants considered the trade-offs in each scenario and stated their preferred test (or chose neither). Results: Preparation and sensitivity for polyps were both significant predictors of preferences (coefficients: −3.834 to −6.346 for preparation, 0.207–0.257 for sensitivity; p<0.0005). These attributes predicted preferences to a similar extent. Realistic specificity values were non-significant (−0.002 to 0.025; p=0.953). Contrary to our hypothesis, probabilities of selecting tests were similar for realistic forms of full-laxative, reduced-laxative and non-laxative preparations (0.362–0.421). However, they were substantially higher for hypothetical improved forms of reduced-laxative or non-laxative preparations with better sensitivity for polyps (0.584–0.837). Conclusions: Uptake of CTC following non-laxative or reduced-laxative preparations is unlikely to be greater than following full-laxative preparation as perceived gains from reduced burden may be diminished by reduced sensitivity. However, both attributes are important so a more sensitive form of reduced-laxative or non-laxative preparation might improve uptake substantially.JRC.I.2-Public Health Policy Suppor
    corecore