The HERMES Back Drift Chambers
The tracking system of the HERMES spectrometer behind the bending magnet
consists of two pairs of large planar 6-plane drift chambers. The design and
performance of these chambers is described. This description comprises details
on the mechanical and electronical design, information about the gas mixture
used and its properties, results on alignment, calibration, resolution, and
efficiencies, and a discussion of the experience gained through the first three
years of operation.Comment: 21 pages, LaTex, 16 figures include
The HERMES Spectrometer
The HERMES experiment is collecting data on inclusive and semi-inclusive deep inelastic scattering of polarised positrons from polarised targets of Il, D, and He-3. These data give information on the spin structure of the nucleon. This paper describes the forward angle spectrometer built for this purpose. The spectrometer includes numerous tracking chambers (micro-strip gas chambers, drift and proportional chambers) in front of and behind a 1.3 T.m magnetic field, as well as an extensive set of detectors for particle identification (a lead-glass calorimeter, a pre-shower detector, a transition radiation detector, and a threshold Cherenkov detector). Two of the main features of the spectrometer are its good acceptance and identification of both positrons and hadrons, in particular pions. These characteristics, together with the purity of the targets, are allowing HERMES to make unique contributions to the understanding of how the spins of the quarks contribute to the spin of the nucleon. (C) 1998 Elsevier Science B.V. All rights reserved
High spin polarisation at the HERA electron storage ring
This paper describes the progress made in 1992 towards increasing the vertical electron beam polarization at HERA. Utilizing harmonic spin-orbit corrections and beam tuning, the vertical polarization has been increased from 15% to nearly 60% at a beam energy of 26.7 GeV. The long-term reproducibility of the polarization is excellent. Measurements of the build-up time and the energy dependence of the polarization are also described. (orig.)Available from TIB Hannover: RA 2999(93-038) / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEDEGerman