3,547 research outputs found

    Virtual integration platform for computational fluid dynamics

    Get PDF
    Computational Fluid Dynamics (CFD) tools used in shipbuilding industry involve multiple disciplines, such as resistance, manoeuvring, and cavitation. Traditionally, the analysis was performed separately and sequentially in each discipline, which often resulted in conflict and inconsistency of hydrodynamic prediction. In an effort to solve such problems for future CFD computations, a Virtual Integration Platform (VIP) has been developed in the University of Strathclyde within two EU FP6 projects - VIRTUE and SAFEDOR1. The VIP provides a holistic collaborative environment for designers with features such as Project/Process Management, Distributed Tools Integration, Global Optimisation, Version Management, and Knowledge Management. These features enhance collaboration among customers, ship design companies, shipyards, and consultancies not least because they bring together the best expertise and resources around the world. The platform has been tested in seven European ship design companies including consultancies. Its main functionalities along with advances are presented in this paper with two industrial applications

    Precise Measurements of the Kilohertz Quasi-Periodic Oscillations in 4U 1728-34

    Get PDF
    We have analyzed seventeen observations of the low-mass X-ray binary and atoll source 4U 1728-34, carried out by the Rossi X-ray Timing Explorer in 1996 and 1997. We obtain precise measurements of the frequencies of the two simultaneous kilohertz quasi-periodic oscillations (kHz QPOs) in this source. We show that the frequency separation between the two QPO, Δν\Delta \nu, is always significantly smaller than the frequency of the nearly-coherent oscillations seen in this source during X-ray bursts, even at the lowest inferred mass accretion rate, when Δν\Delta \nu seems to reach its maximum value. We also find that Δν\Delta \nu decreases significantly, from 349.3±1.7349.3 \pm 1.7 Hz to 278.7±11.6278.7 \pm 11.6 Hz, as the frequency of the lower frequency kHz QPO increases from 615 to 895 Hz. This is the first time that variations of the kHz QPO peak separation are measured in a source which shows nearly-coherent oscillations during bursts.Comment: Accepted for publication in The Astrophysical Journal Letters. Uses AAS LaTex v4.0 (5 pages plus 4 postscript figures

    Spin-dependent transport in metal/semiconductor tunnel junctions

    Get PDF
    This paper describes a model as well as experiments on spin-polarized tunnelling with the aid of optical spin orientation. This involves tunnel junctions between a magnetic material and gallium arsenide (GaAs), where the latter is optically excited with circularly polarized light in order to generate spin-polarized carriers. A transport model is presented that takes account of carrier capture in the semiconductor surface states, and describes the semiconductor surface in terms of a spin-dependent energy distribution function. The so-called surface spin-splitting can be calculated from the balance of the polarized electron and hole flow in the semiconductor subsurface region, the polarized tunnelling current across the tunnel barrier between the magnetic material and the semiconductor surface, and the spin relaxation at the semiconductor surface. Measurements are presented of the circular-polarization-dependent photocurrent (the so-called helicity asymmetry) in thin-film tunnel junctions of Co/Al2O3/GaAs. In the absence of a tunnel barrier, the helicity asymmetry is caused by magneto-optical effects (magnetic circular dichroism). In the case where a tunnel barrier is present, the data cannot be explained by magneto-optical effects alone; the deviations provide evidence that spin-polarized tunnelling due to optical spin orientation occurs. In Co/τ-MnAl/AlAs/GaAs junctions no deviations from the magneto-optical effects are observed, most probably due to the weak spin polarization of τ-MnAl along the tunnelling direction; the latter is corroborated by bandstructure calculations. Finally, the application of photoexcited GaAs for spin-polarized tunnelling in a scanning tunnelling microscope is discussed.

    Three ways to solve the orbit of KIC11558725: a 10 day beaming sdB+WD binary with a pulsating subdwarf

    Get PDF
    The recently discovered subdwarf B (sdB) pulsator KIC11558725 features a rich g-mode frequency spectrum, with a few low-amplitude p-modes at short periods, and is a promising target for a seismic study aiming to constrain the internal structure of this star, and of sdB stars in general. We have obtained ground-based spectroscopic Balmer-line radial-velocity measurements of KIC11558725, spanning the 2010 and 2011 observing seasons. From these data we have discovered that KIC11558725 is a binary with period P=10.05 d, and that the radial-velocity amplitude of the sdB star is 58 km/s. Consequently the companion of the sdB star has a minimum mass of 0.63 M\odot, and is therefore most likely an unseen white dwarf. We analyse the near-continuous 2010-2011 Kepler light curve to reveal orbital Doppler-beaming light variations at the 238 ppm level, which is consistent with the observed spectroscopic orbital radial-velocity amplitude of the subdwarf. We use the strongest 70 pulsation frequencies in the Kepler light curve of the subdwarf as clocks to derive a third consistent measurement of the orbital radial-velocity amplitude, from the orbital light-travel delay. We use our high signal-to-noise average spectra to study the atmospheric parameters of the sdB star, deriving Teff = 27 910K and log g = 5.41 dex, and find that carbon, nitrogen and oxygen are underabundant relative to the solar mixture. Furthermore, we extract more than 160 significant frequencies from the Kepler light curve. We investigate the pulsation frequencies for expected period spacings and rotational splittings. We find period-spacing sequences of spherical-harmonic degrees \ell=1 and \ell=2, and we associate a large fraction of the g-modes in KIC11558725 with these sequences. From frequency splittings we conclude that the subdwarf is rotating subsynchronously with respect to the orbit

    Mass ratio from Doppler beaming and R{\o}mer delay versus ellipsoidal modulation in the Kepler data of KOI-74

    Full text link
    We present a light curve analysis and radial velocity study of KOI-74, an eclipsing A star + white dwarf binary with a 5.2 day orbit. Aside from new spectroscopy covering the orbit of the system, we used 212 days of publicly available Kepler observations and present the first complete light curve fitting to these data, modelling the eclipses and transits, ellipsoidal modulation, reflection, and Doppler beaming. Markov Chain Monte Carlo simulations are used to determine the system parameters and uncertainty estimates. Our results are in agreement with earlier studies, except that we find an inclination of 87.0 \pm 0.4\degree, which is significantly lower than the previously published value. We find that the mass ratio derived from the radial velocity amplitude (q=0.104 \pm 0.004) disagrees with that derived from the ellipsoidal modulation (q=0.052 \pm 0.004} assuming corotation). This was found before, but with our smaller inclination, the discrepancy is even larger than previously reported. Accounting for the rapid rotation of the A-star is found to increase the discrepancy even further by lowering the mass ratio to q=0.047 \pm 0.004. These results indicate that one has to be extremely careful in using the amplitude of an ellipsoidal modulation signal in a close binary to determine the mass ratio, when a proof of corotation is not firmly established. The radial velocities that can be inferred from the detected Doppler beaming in the light curve are found to be in agreement with our spectroscopic radial velocity determination. We also report the first measurement of R{\o}mer delay in a light curve of a compact binary. This delay amounts to -56 \pm 17 s and is consistent with the mass ratio derived from the radial velocity amplitude. The firm establishment of this mass ratio at q=0.104 \pm 0.004 leaves little doubt that the companion of KOI-74 is a low mass white dwarf.Comment: 9 pages, 7 figures, 2 tables; accepted for publication in MNRA

    Lattice sites of ion-implanted Li in diamond

    Get PDF
    Published in: Appl. Phys. Lett. 66 (1995) 2733-2735 citations recorded in [Science Citation Index] Abstract: Radioactive Li ions were implanted into natural IIa diamonds at temperatures between 100 K and 900 K. Emission channelling patterns of a-particles emitted in the nuclear decay of 8Li (t1/2 = 838 ms) were measured and, from a comparison with calculated emission channelling and blocking effects from Monte Carlo simulations, the lattice sites taken up by the Li ions were quantitatively determined. A fraction of 40(5)% of the implanted Li ions were found to be located on tetrahedral interstitial lattice sites, and 17(5)% on substitutional sites. The fractions of implanted Li on the two lattice sites showed no change with temperature, indicating that Li diffusion does not take place within the time window of our measurements.

    Scoring and psychometric validation of the Perception of Anticoagulant Treatment Questionnaire (PACT-Q©)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The 'Perception of Anti-Coagulant Treatment Questionnaire' (PACT-Q) was developed to assess patients' expectations of, and satisfaction with their anticoagulant treatment. This questionnaire needs to be finalised and psychometrically validated.</p> <p>Methods</p> <p>The PACT-Q was included in the United States, the Netherlands and France into three phase III multinational clinical trials conducted to evaluate efficacy and safety of a new long-acting anticoagulant drug (idraparinux) compared to vitamin K antagonist (VKA). PACT-Q was administered to patients with deep venous thrombosis (DVT), atrial fibrillation (AF) or pulmonary embolism (PE) at Day 1, to assess patients' expectations, and at 3 and 6 months to assess patients' satisfaction and treatment convenience and burden. The final structure of the PACT-Q (Principal Component Analysis – PCA – with Varimax Rotation) was first determined and its psychometric properties were then measured with validity of the structure (Multitrait analysis), internal consistency reliability (Cronbach's alpha coefficients) and known-group validity.</p> <p>Results</p> <p>PCA and multitrait analyses showed the multidimensionality of the "Treatment Expectations" dimension, comprising 7 items that had to be scored independently. The "Convenience" and "Burden of Disease and Treatment" dimensions of the hypothesised original structure of the questionnaire were combined, thus resulting in 13 items grouped into the single dimension "Convenience". The "Anticoagulant Treatment Satisfaction" dimension remained unchanged and included 7 items. All items of the "Convenience" and "Anticoagulant Treatment Satisfaction" dimensions displayed good convergent and discriminant validity. The internal consistency reliability was good, with a Cronbach's alpha of 0.84 for the "Convenience" dimension, and 0.76 for the "Anticoagulant Treatment Satisfaction" dimension. Known-group validity was good, especially with regard to occurrence of thromboembolic events within 3 months from randomisation.</p> <p>Conclusion</p> <p>The PACT-Q is a valid and reliable instrument that allows the assessment of patients' expectations and satisfaction regarding anticoagulant treatment, as well as their opinion about treatment convenience of use. Its two-part structure – assessment of expectations at baseline in the first part, and of convenience, burden and treatment satisfaction in the second – was validated and displays good and stable psychometric properties. These results are not sufficient to recommend the use of satisfaction as primary endpoint in clinical trials; further validation work is needed to support the interpretation of PACT-Q dimension scores. However, this first validation makes the PACT-Q an appropriate measure for use in clinical and pharmacoepidemiological research, as well as in real-life studies.</p> <p>Trial Registration</p> <p>(ClinicalTrials.gov numbers, NCT00067093, NCT00062803 and NCT00070655).</p
    corecore