Effects of lacidipine on peak oxygen consumption, neurohormones and invasive haemodynamics in patients with mild to moderate chronic heart failure.
OBJECTIVE: To evaluate the efficacy and safety of the second generation dihydropyridine calcium channel blocker lacidipine in patients with heart failure. DESIGN: Placebo controlled, parallel group, double blind study over 8 weeks. SETTING: General community hospital in Breda, The Netherlands. PATIENTS: A random sample was studied of 25 outpatients with symptoms of mild to moderate heart failure, despite treatment with diuretics, digoxin, and angiotensin converting enzyme inhibitors. Their mean age was 65 years, with mean left ventricular ejection fraction of 0.24 and a peak oxygen consumption of 14.4 ml/min/kg. Two patients dropped out on lacidipine, one patient on placebo. INTERVENTION: Treatment with lacidipine 4 mg once daily or placebo for eight weeks. MAIN OUTCOME MEASURE: Cardiopulmonary exercise testing, invasive haemodynamics, and plasma neurohormones. RESULTS: Treatment with lacidipine 4 mg once daily, as compared to placebo treatment, significantly improved peak oxygen consumption (P < 0.02), cardiac index (P < 0.01), and stroke volume (P < 0.03) paralleled by a decrease in systemic vascular resistance (P < 0.03) and arteriovenous oxygen content difference (P < 0.01). Plasma noradrenaline, plasma renin activity, and aldosterone values did not differ between lacidipine and placebo. CONCLUSIONS: This second generation dihydropyridine may be of value as an adjunct to standard treatment in congestive heart failure patients
Multicenter evaluation of the phosphorylcholine-coated biodivYsio stent in short de novo coronary lesions : the SOPHOS study
AIMS: The BiodivYsio trade mark stent (Biocompatibles Ltd, Farnham, UK) is coated with a phosphorylcholine (PC)-containing copolymer to confer biocompatibility. The SOPHOS (Study Of PHosphorylcholine coating On Stents) study was designed to assess the safety and efficacy of this novel coronary stent and by indirect comparison to indicate equivalence with other formal stent studies. METHODS AND RESULTS: Patients with angina and a single short (#x2A7F;12 mm) de novo lesion in a native coronary artery of >/=2.75 mm diameter were included. A total of 425 patients were allocated in 24 centers. Clinical data were collected at one-, six- and nine-month follow-up. Angiography was performed before and after the stent implantation. In addition, in the first 200 patients (SOPHOS A) angiography was routinely performed at six months. The following 225 patients (SOPHOS B) were merely followed up clinically. The primary end-point of the study, the six-month MACE-rate (MACE = Major Adverse Cardiac Events) was 13.4% (two cardiac death; five Q-wave/nine non-Q-wave myocardial infarctions (MI); nine CABG and 32 target lesion revascularization (TLR), which is similar to the calculated 15% MACE-rate in comparable reference studies. Secondary end-points included among others restenosis at six months in the SOPHOS A population. The target vessel diameter was 2.98 +/- 0.48 mm. Minimal lumen diameter pre/post procedure and at follow-up was 1.00 +/- 0.32, 2.69 +/- 0.37, 1.91 +/- 0.71 mm, respectively. The binary restenosis rate (>/=50% diameter stenosis at follow-up) was 17.7%. CONCLUSION: The coronary BiodivYsio stent is safe and effective as a primary device for the treatment of native coronary artery lesions in patients with stable or unstable angina pectoris. Clinical and angiographic results are in the statistical range of equivalence with comparable studies with other current stents