80 research outputs found
Simulating the detection of the global 21 cm signal with MIST for different models of the soil and beam directivity
The Mapper of the IGM Spin Temperature (MIST) is a new ground-based,
single-antenna, radio experiment attempting to detect the global 21 cm signal
from the Dark Ages and Cosmic Dawn. A significant challenge in this measurement
is the frequency-dependence, or chromaticity, of the antenna beam directivity.
MIST observes with the antenna above the soil and without a metal ground plane,
and the beam directivity is sensitive to the electrical characteristics of the
soil. In this paper, we use simulated observations with MIST to study how the
detection of the global 21 cm signal from Cosmic Dawn is affected by the soil
and the MIST beam directivity. We simulate observations using electromagnetic
models of the directivity computed for single- and two-layer models of the
soil. We test the recovery of the Cosmic Dawn signal with and without beam
chromaticity correction applied to the simulated data. We find that our
single-layer soil models enable a straightforward recovery of the signal even
without chromaticity correction. Two-layer models increase the beam
chromaticity and make the recovery more challenging. However, for the model in
which the bottom soil layer has a lower electrical conductivity than the top
layer, the signal can be recovered even without chromaticity correction. For
the other two-layer models, chromaticity correction is necessary for the
recovery of the signal and the accuracy requirements for the soil parameters
vary between models. These results will be used as a guideline to select
observation sites that are favorable for the detection of the Cosmic Dawn
signal.Comment: Accepted for publication in the Astrophysical Journa
CMB polarimetry with BICEP: instrument characterization, calibration, and performance
BICEP is a ground-based millimeter-wave bolometric array designed to target
the primordial gravity wave signature on the polarization of the cosmic
microwave background (CMB) at degree angular scales. Currently in its third
year of operation at the South Pole, BICEP is measuring the CMB polarization
with unprecedented sensitivity at 100 and 150 GHz in the cleanest available 2%
of the sky, as well as deriving independent constraints on the diffuse
polarized foregrounds with select observations on and off the Galactic plane.
Instrument calibrations are discussed in the context of rigorous control of
systematic errors, and the performance during the first two years of the
experiment is reviewed.Comment: 12 pages, 15 figures, updated version of a paper accepted for
Millimeter and Submillimeter Detectors and Instrumentation for Astronomy IV,
Proceedings of SPIE, 7020, 200
Absolute polarization angle calibration using polarized diffuse Galactic emission observed by BICEP
We present a method of cross-calibrating the polarization angle of a
polarimeter using BICEP Galactic observations. \bicep\ was a ground based
experiment using an array of 49 pairs of polarization sensitive bolometers
observing from the geographic South Pole at 100 and 150 GHz. The BICEP
polarimeter is calibrated to +/-0.01 in cross-polarization and less than +/-0.7
degrees in absolute polarization orientation. BICEP observed the temperature
and polarization of the Galactic plane (R.A= 100 degrees ~ 270 degrees and Dec.
= -67 degrees ~ -48 degrees). We show that the statistical error in the 100 GHz
BICEP Galaxy map can constrain the polarization angle offset of WMAP Wband to
0.6 degrees +\- 1.4 degrees. The expected 1 sigma errors on the polarization
angle cross-calibration for Planck or EPIC are 1.3 degrees and 0.3 degrees at
100 and 150 GHz, respectively. We also discuss the expected improvement of the
BICEP Galactic field observations with forthcoming BICEP2 and Keck
observations.Comment: 13 pages, 10 figures and 2 tables. To appear in Proceedings of SPIE
Astronomical Telescopes and Instrumentation 201
MeerKLASS: MeerKAT Large Area Synoptic Survey
We discuss the ground-breaking science that will be possible with a wide area
survey, using the MeerKAT telescope, known as MeerKLASS (MeerKAT Large Area
Synoptic Survey). The current specifications of MeerKAT make it a great fit for
science applications that require large survey speeds but not necessarily high
angular resolutions. In particular, for cosmology, a large survey over for hours will potentially provide the first
ever measurements of the baryon acoustic oscillations using the 21cm intensity
mapping technique, with enough accuracy to impose constraints on the nature of
dark energy. The combination with multi-wavelength data will give unique
additional information, such as exquisite constraints on primordial
non-Gaussianity using the multi-tracer technique, as well as a better handle on
foregrounds and systematics. Such a wide survey with MeerKAT is also a great
match for HI galaxy studies, providing unrivalled statistics in the pre-SKA era
for galaxies resolved in the HI emission line beyond local structures at z >
0.01. It will also produce a large continuum galaxy sample down to a depth of
about 5\,Jy in L-band, which is quite unique over such large areas and
will allow studies of the large-scale structure of the Universe out to high
redshifts, complementing the galaxy HI survey to form a transformational
multi-wavelength approach to study galaxy dynamics and evolution. Finally, the
same survey will supply unique information for a range of other science
applications, including a large statistical investigation of galaxy clusters as
well as produce a rotation measure map across a huge swathe of the sky. The
MeerKLASS survey will be a crucial step on the road to using SKA1-MID for
cosmological applications and other commensal surveys, as described in the top
priority SKA key science projects (abridged).Comment: Larger version of the paper submitted to the Proceedings of Science,
"MeerKAT Science: On the Pathway to the SKA", Stellenbosch, 25-27 May 201
A cryogenic rotation stage with a large clear aperture for the half-wave plates in the Spider instrument
We describe the cryogenic half-wave plate rotation mechanisms built for and
used in Spider, a polarization-sensitive balloon-borne telescope array that
observed the Cosmic Microwave Background at 95 GHz and 150 GHz during a
stratospheric balloon flight from Antarctica in January 2015. The mechanisms
operate at liquid helium temperature in flight. A three-point contact design
keeps the mechanical bearings relatively small but allows for a large (305 mm)
diameter clear aperture. A worm gear driven by a cryogenic stepper motor allows
for precise positioning and prevents undesired rotation when the motors are
depowered. A custom-built optical encoder system monitors the bearing angle to
an absolute accuracy of +/- 0.1 degrees. The system performed well in Spider
during its successful 16 day flight.Comment: 11 pages, 7 figures, Published in Review of Scientific Instruments.
v2 includes reviewer changes and longer literature revie
Modeling and characterization of the SPIDER half-wave plate
Spider is a balloon-borne array of six telescopes that will observe the
Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the
instrument will make a polarization map of the CMB with approximately one-half
degree resolution at 145 GHz. Polarization modulation is achieved via a
cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have
measured millimeter-wave transmission spectra of the sapphire at room and
cryogenic temperatures. The spectra are consistent with our physical optics
model, and the data gives excellent measurements of the indices of A-cut
sapphire. We have also taken preliminary spectra of the integrated HWP, optical
system, and detectors in the prototype Spider receiver. We calculate the
variation in response of the HWP between observing the CMB and foreground
spectra, and estimate that it should not limit the Spider constraints on
inflation
Pointing control for the SPIDER balloon-borne telescope
We present the technology and control methods developed for the pointing
system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed
to detect the imprint of primordial gravitational waves in the polarization of
the Cosmic Microwave Background radiation. We describe the two main components
of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A
13 kHz PI control loop runs on a digital signal processor, with feedback from
fibre optic rate gyroscopes. This system can control azimuthal speed with <
0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven
linear actuators to rotate the cryostat, which houses the optical instruments,
relative to the outer frame. With the velocity in each axis controlled in this
way, higher-level control loops on the onboard flight computers can implement
the pointing and scanning observation modes required for the experiment. We
have accomplished the non-trivial task of scanning a 5000 lb payload
sinusoidally in azimuth at a peak acceleration of 0.8 deg/s, and a peak
speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing
control accuracy.Comment: 20 pages, 12 figures, Presented at SPIE Ground-based and Airborne
Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume
914
Design and implementation of a noise temperature measurement system for the Hydrogen Intensity and Real-time Analysis eXperiment (HIRAX)
This paper describes the design, implementation, and verification of a
test-bed for determining the noise temperature of radio antennas operating
between 400-800MHz. The requirements for this test-bed were driven by the HIRAX
experiment, which uses antennas with embedded amplification, making system
noise characterization difficult in the laboratory. The test-bed consists of
two large cylindrical cavities, each containing radio-frequency (RF) absorber
held at different temperatures (300K and 77K), allowing a measurement of system
noise temperature through the well-known 'Y-factor' method. The apparatus has
been constructed at Yale, and over the course of the past year has undergone
detailed verification measurements. To date, three preliminary noise
temperature measurement sets have been conducted using the system, putting us
on track to make the first noise temperature measurements of the HIRAX feed and
perform the first analysis of feed repeatability.Comment: 19 pages, 12 figure
Recommended from our members
Characterization of the BICEP Telescope for High-precision Cosmic Microwave Background Polarimetry
The Background Imaging of Cosmic Extragalactic Polarization (BICEP) experiment was designed specifically to search for the signature of inflationary gravitational waves in the polarization of the cosmic microwave background (CMB). Using a novel small-aperture refractor and 49 pairs of polarization-sensitive bolometers, BICEP has completed three years of successful observations at the South Pole beginning in 2006 February. To constrain the amplitude of the inflationary B-mode polarization, which is expected to be at least 7 orders of magnitude fainter than the 3 K CMB intensity, precise control of systematic effects is essential. This paper describes the characterization of potential systematic errors for the BICEP experiment, supplementing a companion paper on the initial cosmological results. Using the analysis pipelines for the experiment, we have simulated the impact of systematic errors on the B-mode polarization measurement. Guided by these simulations, we have established benchmarks for the characterization of critical instrumental properties including bolometer relative gains, beam mismatch, polarization orientation, telescope pointing, sidelobes, thermal stability, and timestream noise model. A comparison of the benchmarks with the measured values shows that we have characterized the instrument adequately to ensure that systematic errors do not limit BICEP's two-year results, and identifies which future refinements are likely necessary to probe inflationary B-mode polarization down to levels below a tensor-to-scalar ratio r = 0.1.Astronom
- …