13 research outputs found

    Concordance Between the AmpFℓSTR®MiniFiler™ and AmpFℓSTR®Identifiler®PCR Amplification Kits in the Kuwaiti Population

    No full text
    The AmpFℓSTR® MiniFiler™ polymerase chain reaction amplification kit, developed and supplied by Applied Biosystems, complements the AmpFℓSTR® Identifiler® polymerase chain reaction amplification kit (Applied Biosystems, Warrington, U.K.) by improving the success rate when profiling DNA that is degraded or contains inhibitors. Before applying the MiniFiler™ kit to casework, the profiles from 200 unrelated Kuwaitis were compared to Identifiler® profiles. Concordance was observed for 99.875% (1598 of 1600) of the compared STR loci. The two discordant profiles displayed allelic dropout: one at the D13S317 locus due to nonamplification of allele 10 in the MiniFiler™ profile, and one at the D18S51 locus due to nonamplification of allele 18 in the Identifiler® profile

    Myocardial deformation assessed by CMR in children after multisystem inflammatory syndrome (MIS-C)

    No full text
    Background: Short-term sequelae of Multisystem Inflammatory Syndrome in Children (MIS-C), recently published by our institution, showed rapid improvement of the cardiac abnormalities within a few weeks after the onset of the disease. However, subtle residual abnormalities, affecting mainly the myocardial interstitium, were shown in some of the patients. The current study aimed to assess myocardial deformation with CMR shortly after MIS-C. Methods: Sixty children were included into the study; 30 following MIS-C (onset-to-scan mean 27 days, SD 11) and 30 controls. Strain values were compared between patients and controls and additionally to published paediatric normal CMR values. U-Mann Whitney test was used for comparison of the myocardial deformation between patients and controls. Results: Median age of the patients was 9.0 years (range 0.99–14.4) and controls 9.8 years (range 4.7–14.9). All conventional CMR parameters in patients were in normal range. Strain values were significantly lower in patients than in controls. When compared to published centile graphs, radial and circumferential global strain was within 2.5th and 97.5th centile in all patients. Eleven patients had global longitudinal strain between 2.5th centile and 50th centile, 1 patient was below 2.5th centile and all the others above 50th centile. Only 3 controls had global longitudinal strain between 2.5th centile and 50th centile, all other had higher strain. Conclusions: This study demonstrates that myocardial deformation indices measured by CMR are within normal range in the vast majority of the patients within a few weeks after the onset of MIS-C. However, when compared to healthy controls, all strain parameters were lower in patients
    corecore