136,706 research outputs found

    Magnetic impurity in the vicinity of a vacancy in bilayer graphene

    Full text link
    We use quantum Monte Carlo method to study a magnetic impurity located next to a vacancy in bilayer graphene with Bernal stacking. Due to the broken symmetry between two sublattices in bilayer system, there exist two different types of vacancy induced localized state. We find that the magnetic property of the adatom located on the adjacent site of the vacancy depends on whether the vacancy belongs to A or B sublattice. In general, local moment is more strongly suppressed if the vacancy belongs to the sublattice A when μ0\mu \sim 0. We switch the values of the chemical potential and study the basic thermodynamic quantities and the correlation functions between the magnetic adatom and the carbon sites.Comment: 3 pages, 4 figures, conferenc

    Dynamic response of some tentative compliant wall structures to convected turbulence fields

    Get PDF
    Some tentative compliant wall structures designed for possible skin friction drag reduction are investigated. Among the structural models considered is a ribbed membrane backed by polyurethane or PVS plastisol. This model is simplified as a beam placed on a viscoelastic foundation as well as on a set of evenly spaced supports. The total length of the beam may be either finite or infinite, and the supports may be either rigid or elastic. Another structural model considered is a membrane mounted over a series of pretensioned wires, also evenly spaced, and the entire membrane is backed by an air cavity. The forcing pressure field is idealized as a frozen random pattern convected downstream at a characteristic velocity. The results are given in terms of the frequency response functions of the system, the spectral density of the structural motion, and the spectral density of the boundary layer pressure including the effect of structural motion. These results are used in a parametric study of structural configurations capable of generating favorable wave lengths, wave amplitudes, and wave speeds in the structural motion for potential drag reduction

    New high fill-factor triangular micro-lens array fabrication method using UV proximity printing

    Get PDF
    A simple and effective method to fabricate a high fill-factor triangular microlens array using the proximity printing in lithography process is reported. The technology utilizes the UV proximity printing by controlling a printing gap between the mask and substrate. The designed approximate triangle microlens array pattern can be fabricated the high fill-factor triangular microlens array in photoresist. It is due to the UV light diffraction to deflect away from the aperture edges and produce a certain exposure in photoresist material outside the aperture edges. This method can precisely control the geometric profile of high fill factor triangular microlens array. The experimental results showed that the triangular micro-lens array in photoresist could be formed automatically when the printing gap ranged from 240 micrometers to 840 micrometers. The gapless triangular microlens array will be used to increases of luminance for backlight module of liquid crystal displays.Comment: Submitted on behalf of EDA Publishing Association (http://irevues.inist.fr/handle/2042/16838

    Design and finite element mode analysis of noncircular gear

    Get PDF
    The noncircular gear transmission is an important branch of the gear transmission, it is characterized by its compact structure, good dynamic equilibration and other advantages, and can be used in the automobile, engineering machine, ship, machine tool, aviation and spaceflight field etc. Studying on the dynamics feature of noncircular gear transmission can improve the ability to carry loads of, reduce the vibration and noise of, increase the life of the noncircular gear transmission machine, provides guidance for the design of the noncircular gear, and has significant theories and practical meanings. In this paper, the gear transmission technique is used to studied the design method of the noncircular gear, which contains distribution of teeth on the pitch curve, designs of the tooth tip curve and the tooth root curve, design of the tooth profile curve, the gear system dynamics principle is introduced to establish dynamics model for the noncircular gear; basic theory of finite element and mode analysis method are applied, finite element model for the noncircular gear is established, natural vibration characteristic of the noncircular gear is studied. And the oval gear is taken as an example, the mathematics software MathCAD, the 3D modeling software UG and the finite element software ABAQUS are used to realize precise 3D model of the oval gear. The finite element method is used, the natural vibration characteristic of the oval gear is studied, the main vibration types and natural frequencies of the oval gear and that of the equivalent cylindrical gears are analyzed and compared, the conclusions received reflect the dynamics performance of the oval gear, and solid foundation is laid for dynamics research and engineering application of the oval gear transmission

    Calibration and Irradiation Study of the BGO Background Monitor for the BEAST II Experiment

    Full text link
    Beam commissioning of the SuperKEKB collider began in 2016. The Beam Exorcism for A STable experiment II (BEAST II) project is particularly designed to measure the beam backgrounds around the interaction point of the SuperKEKB collider for the Belle II experiment. We develop a system using bismuth germanium oxide (BGO) crystals with optical fibers connecting to a multianode photomultiplier tube (MAPMT) and a field-programmable gate array (FPGA) embedded readout board for monitoring the real-time beam backgrounds in BEAST II. The overall radiation sensitivity of this system is estimated to be (2.20±0.26)×1012(2.20\pm0.26)\times10^{-12} Gy/ADU (analog-to-digital unit) with the standard 10 m fibers for transmission and the MAPMT operating at 700 V. Our γ\gamma-ray irradiation study of the BGO system shows that the exposure of BGO crystals to 60^{60}Co γ\gamma-ray doses of 1 krad has led to immediate light output reductions of 25--40%, and the light outputs further drop by 30--45% after the crystals receive doses of 2--4 krad. Our findings agree with those of the previous studies on the radiation hard (RH) BGO crystals grown by the low thermal gradient Czochralski (LTG Cz) technology. The absolute dose from the BGO system is also consistent with the simulation, and is estimated to be about 1.18 times the equivalent dose. These results prove that the BGO system is able to monitor the background dose rate in real time under extreme high radiation conditions. This study concludes that the BGO system is reliable for the beam background study in BEAST II

    Probing annihilations and decays of low-mass galactic dark matter in IceCube DeepCore array: Track events

    Full text link
    The deployment of DeepCore array significantly lowers IceCube's energy threshold to about 10 GeV and enhances the sensitivity of detecting neutrinos from annihilations and decays of light dark matter. To match this experimental development, we calculate the track event rate in DeepCore array due to neutrino flux produced by annihilations and decays of galactic dark matter. We also calculate the background event rate due to atmospheric neutrino flux for evaluating the sensitivity of DeepCore array to galactic dark matter signatures. Unlike previous approaches, which set the energy threshold for track events at around 50 GeV (this choice avoids the necessity of including oscillation effect in the estimation of atmospheric background event rate), we have set the energy threshold at 10 GeV to take the full advantage of DeepCore array. We compare our calculated sensitivity with those obtained by setting the threshold energy at 50 GeV. We conclude that our proposed threshold energy significantly improves the sensitivity of DeepCore array to the dark matter signature for mχ<100m_{\chi}< 100 GeV in the annihilation scenario and mχ<300m_{\chi}<300 GeV in the decay scenario.Comment: 19 pages, 5 figures; match the published versio
    corecore