    MR-guided breast biopsy

    Get PDF

    MRI compared to conventional diagnostic work-up in the detection and evaluation of invasive lobular carcinoma of the breast: a review of existing literature

    Get PDF
    Item does not contain fulltextPURPOSE: The clinical diagnosis and management of invasive lobular carcinoma (ILC) of the breast presents difficulties. Magnetic resonance imaging (MRI) has been proposed as the imaging modality of choice for the evaluation of ILC. Small studies addressing different aspects of MRI in ILC have been presented but no large series to date. To address the usefulness of MRI in the work-up of ILC, we performed a review of the currently published literature. MATERIALS AND METHODS: We performed a literature search using the query "lobular AND (MRI OR MR OR MRT OR magnetic)" in the Cochrane library, PubMed and scholar.google.com, to retrieve all articles that dealt with the use of MRI in patients with ILC. We addressed sensitivity, morphologic appearance, correlation with pathology, detection of additional lesions, and impact of MRI on surgery as different endpoints. Whenever possible we performed meta-analysis of the pooled data. RESULTS: Sensitivity is 93.3% and equal to overall sensitivity of MRI for malignancy in the breast. Morphologic appearance is highly heterogeneous and probably heavily influenced by interreader variability. Correlation with pathology ranges from 0.81 to 0.97; overestimation of lesion size occurs but is rare. In 32% of patients, additional ipsilateral lesions are detected and in 7% contralateral lesions are only detected by MRI. Consequently, MRI induces change in surgical management in 28.3% of cases. CONCLUSION: This analysis indicates MRI to be valuable in the work-up of ILC. It provides additional knowledge that cannot be obtained by conventional imaging modalities which can be helpful in patient treatment

    High rates of breast conservation for large ductal and lobular invasive carcinomas combining multimodality strategies

    Get PDF
    The literature reports low rates of breast conservation after neoadjuvant chemotherapy for operable breast cancers not amenable to initial breast-conserving surgery. This study aims to compare the outcome of lobular vs ductal carcinomas after neoadjuvant chemotherapy. Between 1989 and 1999, 750 patients with clinical stage II/IIIA ductal (672) or lobular (78) invasive breast carcinomas were treated at the Institut Curie with primary anthracycline-based polychemotherapy followed by either breast conservation (surgery and/or radiotherapy) or mastectomy. Median follow-up was 10 years. Clinical response to primary chemotherapy was significantly worse for lobular than for ductal carcinomas (47 vs 60%; P=0.04), but only histological grade remained predictive in multivariate analysis. Breast conservation was high for both ductal and lobular carcinomas (65 and 54%; P=0.07), due, in part, to the use of radiotherapy, either exclusive or preoperative, for respectively 26 and 40% of patients. The lobular type had no adverse effect, neither on locoregional control nor on overall survival, even in the group of patients treated with breast conservation

    Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach.</p> <p>Methods</p> <p>A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009.</p> <p>Results</p> <p>Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (81/719, 11.3%) than in the 8-gauge vacuum-assisted biopsy group (18/724, 2.5%) were recommended for further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for indeterminate/inconclusive findings seen on the original ultrasound-guided diagnostic breast biopsy procedure. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (54/719, 7.5%) than in the 8-gauge vacuum-assisted biopsy group (9/724, 1.2%) personally requested further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for a benign finding seen on the original ultrasound-guided diagnostic breast biopsy procedure.</p> <p>Conclusions</p> <p>In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information.</p

    Magnetic resonance-guided, vacuum-assisted breast biopsy - Results from a European Multicenter Study of 538 lesions

    No full text
    BACKGROUND. The objective of this study was to determine the accuracy, reproducibility, and clinical value of magnetic resonance (MR)-guided, vacuum-assisted breast biopsy (MR-VAB) in a prospective, multicenter study. METHODS. in 5 European centers, MR-VAB was performed or attempted on 538 suspicious lesions that were visible or could targeted only by MR imaging (MRI). Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign biopsy results were verified by retrospective correlation of histology with preinterventional and postinterventional MRI studies. Follow-up of 24-48 months (median, 32 months) was available for 491 of 538 patients. RESULTS. MR-VAB was unsuccessful or was not completed in 21 of 538 patients, for which an immediate repeat biopsy was recommended. Five hundred seventeen of 538 performed VAB procedures (96%) were successful. Histology yielded 138 (27%) malignancies, 17 (3%) atypical ductal hyperplasias, and 362 (70%) benign entities. No false-negative diagnoses occurred among the 517 successful MR-VAB procedures. The positive predictive value of VAB depended on patient preselection, which differed according to the indication for the initial MRI study. CONCLUSIONS. The results of this study indicated that MR-VAB offers excellent accuracy. Small lesion size did not prove to be a limitation

    European quadricentric evaluation of a breast MR biopsy and localization device: technical improvements based on phase-I evaluation

    No full text
    Our purpose was to report about technical success, problems and solutions, as experienced in a first multicentre study on MR-guided localisation or vacuum biopsy of breast lesions. The study was carried out at four European sites using a dedicated prototype breast biopsy device. Experiences with 49 scheduled localisation procedures and 188 vacuum biopsies are reported. Apart from 35 dropped indications, one localisation procedure and 9 vacuum biopsies were not possible (3 times space problems due to obesity, 2 times too strong compression, 3 times impaired access froth medially, 2 times impaired access due to a metal bar). Problems due to too strong compression were recognised by repeat MR without compression. During the procedure problems leading to an uncertain result occurred in eight vacuum biopsies, two related to the procedure: one limited access, and one strong post-biopsy enhancement. Improvements after phase-I study concerned removal of the metal bar, development of an improved medial access, of a profile imitating the biopsy gun, optimisation of compression plates and improved software support. The partners agreed that the improvements answered all important technical problems