81 research outputs found

    Outcomes from elective colorectal cancer surgery during the SARS-CoV-2 pandemic

    Get PDF
    This study aimed to describe the change in surgical practice and the impact of SARS-CoV-2 on mortality after surgical resection of colorectal cancer during the initial phases of the SARS-CoV-2 pandemic

    Plasma sputtering deposition of PEMFC porous carbon platinum electrodes

    No full text
    in press. available online Nov. 2007International audienc

    Analysis of unresolved thermometric groups of rotational lines of the OH UV spectrum in the wavelength range 310-378 NM

    No full text
    International audiencePrevious experimental and theoretical studies [1, 2, 3] of the UV spectrum of the OH radical (band head at 306.357 nm, transition Α2ÎŁ,v=0→Χ2Π,vâ€Č=0), easily observed in hot gases containing oxygen and hydrogen (flames, plasma chemistry), have showed the existence of three groups of unresolved rotational lines which evolution against the rotational temperature is sensitive and monotonous. From a numerical simulation of the UV OH spectrum obtained with the experimental data of Diecke et Crosswhite [4], the variations of the amplitude of these unresolved groups of lines were calibrated as a function of the temperature and of the optical apparatus function. Since the 3 groups of unresolved rotational lines may be perturbed by atomic lines coming from electrode materials in plasma processes (it is the case for neutral aluminium lines at the wavelength 308.2 nm and 309.2 nm), the previous studies have been extended to other groups of unresolved lines in the wavelength range 310−318 nm. Experiments using an oxyacetylene flame clearly demonstrate that the new groups of unresolved lines give a too high rotational temperature value. This effect can be explained with an analysis of the different rotational components that constitute these unresolved groups of lines

    Etude expérimentale des phénomÚnes de coalescence dans les systÚmes bulles-gouttes

    No full text
    A l'occasion d'une étude sur les séparations eau-hydrocarbures par flottation, nous avons été amenés à étudier expérimentalement les coalescences bulle-goutte, goutte-goutte et bulle-bulle dans le systÚme triphasique eau-air-kérosÚne. Les 4 montages expérimentaux décrits nous ont permis d'étudier les aspects statiques (structure du complexe bulle-goutte qui se forme) et dynamiques (temps de coalescence moyens bulle-goutte, goutte-goutte et bulle-bulle) et d'étudier l'influence de composés transférables d'une phase à l'autre sur ces temps de coalescence moyens. Du point de vue statique, la configuration stable du complexe bulle d'air-goutte de kérosÚne correspond à la formation à l'interface eau-air d'un film d'hydrocarbure qui entoure la bulle d'air, Par contre, la fixation d'une bulle d'air à la périphérie d'une goutte de kérosÚne, selon la disposition classique dans la flottation des solides, ne s'observe ici que rarement et toujours de façon transitoire. D'un point de vue cinétique on observe que : - les coalescences bulle-bulle ou goutte-goutte sont toujours favorisées (les temps de coalescence moyens diminuent) lorsqu'on introduit dans la phase gaz ou dans l'une des phases liquides un composé transférable dans l'autre phase liquide; - les coalescences bulle-goutte sont favorisées par la présence dans la phase gaz d'un composé transférable dans la phase continue aqueuse ou par la présence dans la phase dispersée liquide d'un composé transférable dans la phase continue aqueuse; - les coalescences bulle-goutte sont défavorisées par la présence dans la phase continue aqueuse d'un composé transférable sur les gouttes constituant la phase dispersée liquide

    Spectroscopie optique pour l'investigation des plasmas transitoires

    No full text
    This chapter is dedicated to the presentation of basic concepts of plasma diagnostics via spectroscopy techniques, including optical emission spectroscopy and absorption spectroscopy. The measurements of temperature and electron density are illustrated via several examples of transient atmospheric plasmas generated by electrical and optical discharges, for which the validity conditions and the measurements limitations are discussed. Finally, the influence of self-absorption on plasma emission is discussed, and the appropriate modeling using the radiation transfer equation is introduced. This chapter is addressed to beginners in optical spectroscopy to help them discovering this very powerful technique. Readers wishing to use this technique to diagnose their plasmas are advised to consult more specialized books

    Etude expérimentale des phénomÚnes de coalescence dans les systÚmes bulles-gouttes Experimental Study of Coalescence Phenomena in Bubble-Drop Systems

    No full text
    A l'occasion d'une étude sur les séparations eau-hydrocarbures par flottation, nous avons été amenés à étudier expérimentalement les coalescences bulle-goutte, goutte-goutte et bulle-bulle dans le systÚme triphasique eau-air-kérosÚne. Les 4 montages expérimentaux décrits nous ont permis d'étudier les aspects statiques (structure du complexe bulle-goutte qui se forme) et dynamiques (temps de coalescence moyens bulle-goutte, goutte-goutte et bulle-bulle) et d'étudier l'influence de composés transférables d'une phase à l'autre sur ces temps de coalescence moyens. Du point de vue statique, la configuration stable du complexe bulle d'air-goutte de kérosÚne correspond à la formation à l'interface eau-air d'un film d'hydrocarbure qui entoure la bulle d'air, Par contre, la fixation d'une bulle d'air à la périphérie d'une goutte de kérosÚne, selon la disposition classique dans la flottation des solides, ne s'observe ici que rarement et toujours de façon transitoire. D'un point de vue cinétique on observe que : - les coalescences bulle-bulle ou goutte-goutte sont toujours favorisées (les temps de coalescence moyens diminuent) lorsqu'on introduit dans la phase gaz ou dans l'une des phases liquides un composé transférable dans l'autre phase liquide; - les coalescences bulle-goutte sont favorisées par la présence dans la phase gaz d'un composé transférable dans la phase continue aqueuse ou par la présence dans la phase dispersée liquide d'un composé transférable dans la phase continue aqueuse; - les coalescences bulle-goutte sont défavorisées par la présence dans la phase continue aqueuse d'un composé transférable sur les gouttes constituant la phase dispersée liquide. During a study of water-hydrocarbon separations by flotation, we were led to make an experimental examination of bubble-drop, drop-drop and bubble-bubble coalescences in a three-phase water-air-kerosene system. The four experimental arrangements described enabled us to investigate the static aspects (structure of the bubble-drop complex formed) and dynamic aspects (average bubble-drop, drop-drop and bubble-bubble coalescence times) as well as the influence of compounds transferable from one phase to the other in these average coalescence times. From the static point of view, the stable configuration of the air-bubble/drop of kerosene complex corresponds to the formation of a hydrocarbon film surrounding the air bubble at the water-air interface. However, the fixing of an air bubble on the periphery of a drop of kerosene, according to the conventional pattern in the flotation of solids, is found only rarely here and always in a transitory way. From the kinetic point of view, we found that:(a) Bubble-bubble or drop-drop coalescences are always favored (the average coalescence times decrease) when a compound transferable into the other liquid phase is introduced into the gas phase or one of the liquid phases. (b) Bubble-drop coalescences are favored by the presence in the gas phase of a compound transferable to the continuous aqueous phase or by the presence in the dispersed liquid phase of a compound transferable to the continuous aqueous phase. (c) Bubble-drop coalescences are disfavored by the presence in the continuous aqueous phase of a compound transferable onto the drops making up the dispersed liquid phase

    Waermeuebergang und effektives Schergefaelle in Blasensaeulen-Bioreaktoren mit Xanthan-Loesungen

    No full text
    SIGLEAvailable as manuscript MS 1627/87 from VCH Verlagsges., Weinheim (Germany, F.R.) / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDEGerman

    Vorbereitung der WerkstĂŒcke fĂŒr die elektrolytische Oxydation

    No full text
    • 

    corecore