185 research outputs found

    Cost-effectiveness of methenamine hippurate compared with antibiotic prophylaxis for the management of recurrent urinary tract infections in secondary care: a multicentre, open-label, randomised, non-inferiority trial

    Get PDF
    \ua9 Author(s) (or their employer(s)) 2024.Objectives To estimate the cost-effectiveness of methenamine hippurate compared with antibiotic prophylaxis in the management of recurrent urinary tract infections. Design Multicentre, open-label, randomised, non-inferiority trial. Setting Eight centres in the UK, recruiting from June 2016 to June 2018. Participants Women aged ≥18 years with recurrent urinary tract infections, requiring prophylactic treatment. Interventions Women were randomised to receive once-daily antibiotic prophylaxis or twice-daily methenamine hippurate for 12 months. Treatment allocation was not masked and crossover between arms was allowed. Primary and secondary outcome measures The primary economic outcome was the incremental cost per quality-adjusted life year (QALY) gained at 18 months. All costs were collected from a UK National Health Service perspective. QALYs were estimated based on responses to the EQ-5D-5L administered at baseline, 3, 6, 9, 12 and 18 months. Incremental costs and QALYs were estimated using an adjusted analysis which controlled for observed and unobserved characteristics. Stochastic sensitivity analysis was used to illustrate uncertainty on a cost-effectiveness plane and a cost-effectiveness acceptability curve. A sensitivity analysis, not specified in the protocol, considered the costs associated with antibiotic resistance. Results Data on 205 participants were included in the economic analysis. On average, methenamine hippurate was less costly (−\ua340; 95% CI: −684 to 603) and more effective (0.014 QALYs; 95% CI: −0.05 to 0.07) than antibiotic prophylaxis. Over the range of values considered for an additional QALY, the probability of methenamine hippurate being considered cost-effective ranged from 51% to 67%. Conclusions On average, methenamine hippurate was less costly and more effective than antibiotic prophylaxis but these results are subject to uncertainty. Methenamine hippurate is more likely to be considered cost-effectiv

    Good Statistical Practice—development of tailored Good Clinical Practice training for statisticians

    Get PDF
    \ua9 The Author(s) 2024.Background: Statisticians are fundamental in ensuring clinical research, including clinical trials, are conducted with quality, transparency, reproducibility and integrity. Good Clinical Practice (GCP) is an international quality standard for the conduct of clinical trials research. Statisticians are required to undertake training on GCP but existing training is generic and, crucially, does not cover statistical activities. This results in statisticians undertaking training mostly unrelated to their role and variation in awareness and implementation of relevant regulatory requirements with regards to statistical conduct. The need for role-relevant training is recognised by the UK NHS Health Research Authority and the Medicines and Healthcare products Regulatory Agency (MHRA). Methods: The Good Statistical Practice (GCP for Statisticians) project was instigated by the UK Clinical Research Collaboration (UKCRC) Registered Clinical Trials Unit (CTU) Statisticians Operational Group and funded by the National Institute for Health and Care Research (NIHR), to develop materials to enable role-specific GCP training tailored to statisticians. Review of current GCP training was undertaken by survey. Development of training materials were based on MHRA GCP. Critical review and piloting was conducted with UKCRC CTU and NIHR researchers with comment from MHRA. Final review was conducted through the UKCRC CTU Statistics group. Results: The survey confirmed the need and desire for the development of dedicated GCP training for statisticians. An accessible, comprehensive, piloted training package was developed tailored to statisticians working in clinical research, particularly the clinical trials arena. The training materials cover legislation and guidance for best practice across all clinical trial processes with statistical involvement, including exercises and real-life scenarios to bridge the gap between theory and practice. Comprehensive feedback was incorporated. The training materials are freely available for national and international adoption. Conclusion: All research staff should have training in GCP yet the training undertaken by most academic statisticians does not cover activities related to their role. The Good Statistical Practice (GCP for Statisticians) project has developed and extensively piloted new, role-specific, comprehensive, accessible GCP training tailored to statisticians working in clinical research, particularly the clinical trials arena. This role-specific training will encourage best practice, leading to transparent and reproducible statistical activity, as required by regulatory authorities and funders

    Not all uncivil behaviours are equal: exploring responses to incivility in veterinary practice using vignettes

    Get PDF
    Workplace incivility is considered a common workplace stressor, linked to a range of adverse impacts such as reduced wellbeing. However, there is a lack of research focused on how targets of incivility respond. The current study addresses that gap by examining responses to incivility within veterinary practice. Veterinarians and veterinary nurses (  = 132) evaluated six scenarios depicting two types of incivility (direct e.g. demeaning comments/indirect, for example, ignoring someone) across three instigators (clients, co-workers, senior colleagues), reporting their perception and appraisal of the uncivil behaviour depicted along with potential responses. Direct incivility was linked to responses such as reciprocation, exit, and support seeking, whereas indirect incivility was associated with affiliative and ignoring responses. Negative appraisal of incivility predicted a higher likelihood of exit, avoidance, support seeking and reporting responses. These findings suggest that incivility targets utilise a broad range of response options and adapt their response dependent on the situation

    Evaluation of erectile potency and radiation dose to the penile bulb using image guided radiotherapy in the CHHiP trial

    Get PDF
    Background and purpose: The penile bulb (PB) dose may be critical in development of post prostate radiotherapy erectile dysfunction (ED). This study aimed to generate PB dose constraints based on dose-volume histograms (DVHs) in patients treated with prostate radiotherapy, and to identify clinical and dosimetric parameters that predict the risk of ED post prostate radiotherapy. / Materials and methods: Penile bulb DVHs were generated for 276 patients treated within the randomised IGRT substudy of the multicentre randomised trial, CHHiP. Incidence of ED in relation to dose and randomised IGRT groups were evaluated using Wilcoxon rank sum, Chi-squared test and atlases of complication incidence. Youden index was used to find dose-volume constraints that discriminated for ED. Multivariate analysis (MVA) of effect of dosimetry, clinical and patient-related variables was performed. / Results: Reduced treatment margins using IGRT (IGRT-R) produced significantly reduced mean PB dose compared with standard margins (IGRT-S) (median: 25 Gy (IGRT-S) versus 11 Gy (IGRT-R); p < 0.0001). Significant difference in both mean (median: 23 Gy (ED) vs. 18 Gy (no ED); p = 0.011) and maximum (median: 59 Gy (ED) vs. 52 Gy (no ED); p = 0.018) PB doses between those with and without clinician reported ED were identified. Mean PB dose cut-point for ED was derived at around 20 Gy. On MVA, PB mean dose and age predicted for impotence. / Conclusion: PB dose appears predictive of post-radiotherapy ED with calculated threshold mean dose of around 20 Gy, substantially lower than published recommendations. IGRT-R enables favourable PB dosimetry and can be recommended provided prostate coverage is not compromised

    Evaluation of erectile potency and radiation dose to the penile bulb using image guided radiotherapy in the CHHiP trial

    Get PDF
    Background and purpose The penile bulb (PB) dose may be critical in development of post prostate radiotherapy erectile dysfunction (ED). This study aimed to generate PB dose constraints based on dose-volume histograms (DVHs) in patients treated with prostate radiotherapy, and to identify clinical and dosimetric parameters that predict the risk of ED post prostate radiotherapy. Materials and methods Penile bulb DVHs were generated for 276 patients treated within the randomised IGRT substudy of the multicentre randomised trial, CHHiP. Incidence of ED in relation to dose and randomised IGRT groups were evaluated using Wilcoxon rank sum, Chi-squared test and atlases of complication incidence. Youden index was used to find dose-volume constraints that discriminated for ED. Multivariate analysis (MVA) of effect of dosimetry, clinical and patient-related variables was performed. Results Reduced treatment margins using IGRT (IGRT-R) produced significantly reduced mean PB dose compared with standard margins (IGRT-S) (median: 25 Gy (IGRT-S) versus 11 Gy (IGRT-R); p < 0.0001). Significant difference in both mean (median: 23 Gy (ED) vs. 18 Gy (no ED); p = 0.011) and maximum (median: 59 Gy (ED) vs. 52 Gy (no ED); p = 0.018) PB doses between those with and without clinician reported ED were identified. Mean PB dose cut-point for ED was derived at around 20 Gy. On MVA, PB mean dose and age predicted for impotence. Conclusion PB dose appears predictive of post-radiotherapy ED with calculated threshold mean dose of around 20 Gy, substantially lower than published recommendations. IGRT-R enables favourable PB dosimetry and can be recommended provided prostate coverage is not compromised

    Characterisation of key genotypic and phenotypic traits of clinical cystic fibrosis Staphylococcus aureus isolates

    Get PDF
    Introduction. One third of people with CF in the UK are co-infected by both Staphylococcus aureus and Pseudomonas aeruginosa. Chronic bacterial infection in CF contributes to the gradual destruction of lung tissue, and eventually respiratory failure in this group. Gap Statement. The contribution of S. aureus to cystic fibrosis (CF) lung decline in the presence or absence of P. aeruginosa is unclear. Defining the molecular and phenotypic characteristics of a range of S. aureus clinical isolates will help further understand its pathogenic capabilities. Aim. Our objective was to use molecular and phenotypic tools to characterise twenty-five clinical S. aureus isolates collected from mono- and coinfection with P. aeruginosa from people with CF at the Royal Victoria Infirmary, Newcastle upon Tyne. Methodology. Genomic DNA was extracted and sequenced. Multilocus sequence typing was used to construct phylogeny from the seven housekeeping genes. A pangenome was calculated using Roary, and cluster of Orthologous groups were assigned using eggNOG-mapper which were used to determine differences within core, accessory, and unique genomes. Characterisation of sequence type, clonal complex, agr and spa types was carried out using PubMLST, eBURST, AgrVATE and spaTyper, respectively. Antibiotic resistance was determined using Kirby-Bauer disc diffusion tests. Phenotypic testing of haemolysis was carried out using ovine red blood cell agar plates and mucoid phenotypes visualised using Congo red agar. Results. Clinical strains clustered closely based on agr type, sequence type and clonal complex. COG analysis revealed statistically significant enrichment of COG families between core, accessory and unique pangenome groups. The unique genome was significantly enriched for replication, recombination and repair, and defence mechanisms. The presence of known virulence genes and toxins were high within this group, and unique genes were identified in 11 strains. Strains which were isolated from the same patient all surpassed average nucleotide identity thresholds, however, differed in phenotypic traits. Antimicrobial resistance to macrolides was significantly higher in the coinfection group. Conclusion. There is huge variation in genetic and phenotypic capabilities of S. aureus strains. Further studies on how these may differ in relation to other species in the CF lung may give insight into inter-species interactions

    Conventional versus hypofractionated high-dose intensity-modulated radiotherapy for prostate cancer: 5-year outcomes of the randomised, non-inferiority, phase 3 CHHiP trial

    Get PDF
    SummaryBackgroundProstate cancer might have high radiation-fraction sensitivity that would give a therapeutic advantage to hypofractionated treatment. We present a pre-planned analysis of the efficacy and side-effects of a randomised trial comparing conventional and hypofractionated radiotherapy after 5 years follow-up.MethodsCHHiP is a randomised, phase 3, non-inferiority trial that recruited men with localised prostate cancer (pT1b–T3aN0M0). Patients were randomly assigned (1:1:1) to conventional (74 Gy delivered in 37 fractions over 7·4 weeks) or one of two hypofractionated schedules (60 Gy in 20 fractions over 4 weeks or 57 Gy in 19 fractions over 3·8 weeks) all delivered with intensity-modulated techniques. Most patients were given radiotherapy with 3–6 months of neoadjuvant and concurrent androgen suppression. Randomisation was by computer-generated random permuted blocks, stratified by National Comprehensive Cancer Network (NCCN) risk group and radiotherapy treatment centre, and treatment allocation was not masked. The primary endpoint was time to biochemical or clinical failure; the critical hazard ratio (HR) for non-inferiority was 1·208. Analysis was by intention to treat. Long-term follow-up continues. The CHHiP trial is registered as an International Standard Randomised Controlled Trial, number ISRCTN97182923.FindingsBetween Oct 18, 2002, and June 17, 2011, 3216 men were enrolled from 71 centres and randomly assigned (74 Gy group, 1065 patients; 60 Gy group, 1074 patients; 57 Gy group, 1077 patients). Median follow-up was 62·4 months (IQR 53·9–77·0). The proportion of patients who were biochemical or clinical failure free at 5 years was 88·3% (95% CI 86·0–90·2) in the 74 Gy group, 90·6% (88·5–92·3) in the 60 Gy group, and 85·9% (83·4–88·0) in the 57 Gy group. 60 Gy was non-inferior to 74 Gy (HR 0·84 [90% CI 0·68–1·03], pNI=0·0018) but non-inferiority could not be claimed for 57 Gy compared with 74 Gy (HR 1·20 [0·99–1·46], pNI=0·48). Long-term side-effects were similar in the hypofractionated groups compared with the conventional group. There were no significant differences in either the proportion or cumulative incidence of side-effects 5 years after treatment using three clinician-reported as well as patient-reported outcome measures. The estimated cumulative 5 year incidence of Radiation Therapy Oncology Group (RTOG) grade 2 or worse bowel and bladder adverse events was 13·7% (111 events) and 9·1% (66 events) in the 74 Gy group, 11·9% (105 events) and 11·7% (88 events) in the 60 Gy group, 11·3% (95 events) and 6·6% (57 events) in the 57 Gy group, respectively. No treatment-related deaths were reported.InterpretationHypofractionated radiotherapy using 60 Gy in 20 fractions is non-inferior to conventional fractionation using 74 Gy in 37 fractions and is recommended as a new standard of care for external-beam radiotherapy of localised prostate cancer.FundingCancer Research UK, Department of Health, and the National Institute for Health Research Cancer Research Network

    Broadened Population-Level Frequency Tuning in Human Auditory Cortex of Portable Music Player Users

    Get PDF
    Nowadays, many people use portable players to enrich their daily life with enjoyable music. However, in noisy environments, the player volume is often set to extremely high levels in order to drown out the intense ambient noise and satisfy the appetite for music. Extensive and inappropriate usage of portable music players might cause subtle damages in the auditory system, which are not behaviorally detectable in an early stage of the hearing impairment progress. Here, by means of magnetoencephalography, we objectively examined detrimental effects of portable music player misusage on the population-level frequency tuning in the human auditory cortex. We compared two groups of young people: one group had listened to music with portable music players intensively for a long period of time, while the other group had not. Both groups performed equally and normally in standard audiological examinations (pure tone audiogram, speech test, and hearing-in-noise test). However, the objective magnetoencephalographic data demonstrated that the population-level frequency tuning in the auditory cortex of the portable music player users was significantly broadened compared to the non-users, when attention was distracted from the auditory modality; this group difference vanished when attention was directed to the auditory modality. Our conclusion is that extensive and inadequate usage of portable music players could cause subtle damages, which standard behavioral audiometric measures fail to detect in an early stage. However, these damages could lead to future irreversible hearing disorders, which would have a huge negative impact on the quality of life of those affected, and the society as a whole
    • …
    corecore