17 research outputs found

    Microvolt T-wave alternans as a predictor of mortality and severe arrhythmias in patients with left-ventricular dysfunction: a systematic review and meta-analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Studies have demonstrated that the use of implantable cardioverter defibrillators (ICDs) is effective for the primary prevention of arrhythmic events but due to imposing costs, there remains a need to identify which patients will derive the greatest benefit. Microvolt T-wave alternans (MTWA) has been proposed to assist in this stratification.</p> <p>Methods</p> <p>We systematically searched the literature using MEDLINE, EMBASE, Current Contents, the Cochrane Library, INAHTA, and the Web of Science to identify all primary prevention randomized controlled trials and prospective cohort studies with at least 12 months of follow-up examining MTWA as a predictor of mortality and severe arrhythmic events in patients with severe left-ventricular dysfunction. The search was limited to full-text English publications between January 1990 and May 2007. The primary outcome was a composite of mortality and severe arrhythmias. Data were synthesized using Bayesian hierarchical models.</p> <p>Results</p> <p>We identified no trials and 8 published cohort studies involving a total of 1,946 patients, including 332 positive, 656 negative, 84 indeterminate, and 874 non-negative (which includes both positive and indeterminate tests) MTWA test results. The risk of mortality or severe arrhythmic events was higher in patients with a positive MTWA compared to a negative test (RR = 2.7, 95% credible interval (CrI) = 1.4, 6.1). Similar results were obtained when comparing non-negative MTWA to a negative test.</p> <p>Conclusion</p> <p>A positive MTWA test predicts mortality or severe arrhythmic events in a population of individuals with severe left ventricular dysfunction. However, the wide credible interval suggests the clinical utility of this test remains incompletely defined, ranging from very modest to substantial. Additional high quality studies are required to better refine the role of MTWA in the decision making process for ICD implantation.</p

    Elevated γ-glutamyltransferase in implantable cardioverter defibrillator patients

    Full text link
    BACKGROUND: Elevated γ-glutamyltransferase (GGT) is a new risk factor for cardiovascular diseases, but its impact on ventricular tachyarrhythmia occurrence and survival in patients with an implantable cardioverter defibrillator (ICD) is unknown. METHODS AND RESULTS: Considering that GGT levels are gender-dependent, female ICD recipients were excluded from our database because of the low incidence of events. In a retrospective analysis, appropriate ICD therapy (both shocks and antitachycardia pacing due to ventricular tachyarrhythmias) occurred in 31.9% of 320 male patients who had received an ICD for primary prevention (median follow-up of 2.3 years), and in 55.1% of 423 male patients who had received an ICD for secondary prevention (median follow-up of 3.9 years). Compared to normal low GGT plasma levels (below 28 U/L), total mortality but not risk for appropriate ICD therapy was elevated for higher GGT categories (p for trend = 0.004 in primary prevention and p for trend = 0.002 in secondary prevention, respectively). In Cox regression analysis, elevated GGT (>56 U/L) remained an independent predictor of death both in primary (p = 0.011) and in secondary prevention (p = 0.006). Patients with elevated GGT and renal insufficiency defined by an estimated glomerular filtration rate <60 ml/min/1.73 m(2) suffered from excess total mortality jeopardizing the benefit of ICD therapy. CONCLUSION: Elevation of GGT is an important adverse prognostic parameter in ICD patients. A possible role of GGT for improved patient selection for ICD therapy deserves further investigation
    corecore