275 research outputs found
Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allow the location of the interaction to be determined with ≲ 1mm resolution at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of σ_E = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly pixelized athermal phonon sensors for ∼1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering
Status of BetaCage: an Ultra-sensitive Screener for Surface Contamination
BetaCage, a gaseous neon time-projection chamber, has been proposed as a viable screener for emitters of low-energy alphas and electrons to which commercial radioactivity counting techniques are insensitive. Using radiopure materials for construction, active and passive shielding from extrinsic backgrounds, large counting area and minimal detector mass, BetaCage will be able to achieve sensitivities of 10^(−5) counts keV^(−1) kg^(−1) day^(−1) in a few days of running time. We report on progress in prototype development work since the last meeting of this workshop
Maximum likelihood analysis of low energy CDMS II germanium data
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from ^(210)Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model
The BetaCage, an ultra-sensitive screener for surface contamination
Material screening for identifying low-energy electron emitters and
alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g.,
dark-matter direct detection and neutrinoless double-beta decay) for which
surface radiocontamination has become an increasingly important background. The
BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive
(and nondestructive) screener for alpha- and beta-emitting surface contaminants
to which existing screening facilities are insufficiently sensitive.
Sensitivity goals are 0.1 betas per keV-m-day and 0.1 alphas per m-day,
with the former limited by Compton scattering of photons in the screening
samples and (thanks to tracking) the latter expected to be signal-limited;
radioassays and simulations indicate backgrounds from detector materials and
radon daughters should be subdominant. We report on details of the background
simulations and detector design that provide the discrimination, shielding, and
radiopurity necessary to reach our sensitivity goals for a chamber with a
9595 cm sample area positioned below a 40 cm drift region and
monitored by crisscrossed anode and cathode planes consisting of 151 wires
each.Comment: 5 pages, 3 figures, Proceedings of Low Radioactivity Techniques (LRT)
2013, Gran Sasso, Italy, April 10-12, 201
First Direct Limits on Lightly Ionizing Particles with Electric Charge Less than e=6
While the standard model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically produced relativistic particles with electric charge lower than e/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers finds no candidates, thereby excluding new parameter space for particles with electric charges between e/6 and e/200
Modeling the power flow in normal conductor-insulator-superconductor junctions
Normal conductor-insulator-superconductor (NIS) junctions promise to be interesting for x-ray and phonon sensing applications, in particular due to the expected self-cooling of the N electrode by the tunneling current. Such cooling would enable the operation of the active element of the sensor below the cryostat temperature and at a correspondingly higher sensitivity. It would also allow the use of MS junctions as microcoolers. At present, this cooling has not been realized in large area junctions (suitable for a number of detector applications). In this article, we discuss a detailed modeling of the heat flow in such junctions; we show how the heat flow into the normal electrode by quasiparticle back-tunneling and phonon absorption from quasiparticle pair recombination can overcompensate the cooling power. This provides a microscopic explanation of the self-heating effects we observe in our large area NIS junctions. The model suggests a number of possible solutions
Quasiparticle Trapping in Microwave Kinetic Inductance Strip Detectors
Microwave Kinetic Inductance Detectors (MKIDs) are thin-film, superconducting resonators, which are attractive for making large detector arrays due to their natural frequency domain multiplexing at GHz frequencies. For X-ray to IR wavelengths, MKIDs can provide high-resolution energy and timing information for each incoming photon. By fabricating strip detectors consisting of a rectangular absorber coupled to MKIDs at each end, high quantum efficiency and spatial resolution can be obtained. A similar geometry is being pursued for phonon sensing in a WIMP dark matter detector. Various materials have been tested including tantalum, tin, and aluminum for the absorbing strip, and aluminum, titanium, and aluminum manganese for the MKID. Initial Ta/Al X-ray devices have shown energy resolutions as good as 62 eV at 6 keV. A Ta/Al UV strip detector with an energy resolution of 0.8 eV at 4.9 eV has been demonstrated, but we find the coupling of the MKIDs to the absorbers is unreliable for these thinner devices. We report on progress probing the thicknesses at which the absorber/MKID coupling begins to degrade by using a resonator to inject quasiparticles directly into the absorber. In order to eliminate the absorber/MKID interface, a modified design for implanted AlMn/Al UV strip detectors was developed, and results showing good transmission of quasiparticles from the absorber to MKID in these devices are presented
Antenna-coupled TES bolometer arrays for CMB polarimetry
We describe the design and performance of polarization selective
antenna-coupled TES arrays that will be used in several upcoming Cosmic
Microwave Background (CMB) experiments: SPIDER, BICEP-2/SPUD. The fully
lithographic polarimeter arrays utilize planar phased-antennas for collimation
(F/4 beam) and microstrip filters for band definition (25% bandwidth). These
devices demonstrate high optical efficiency, excellent beam shapes, and
well-defined spectral bands. The dual-polarization antennas provide
well-matched beams and low cross polarization response, both important for
high-fidelity polarization measurements. These devices have so far been
developed for the 100 GHz and 150 GHz bands, two premier millimeter-wave
atmospheric windows for CMB observations. In the near future, the flexible
microstrip-coupled architecture can provide photon noise-limited detection for
the entire frequency range of the CMBPOL mission. This paper is a summary of
the progress we have made since the 2006 SPIE meeting in Orlando, FL
Antenna-coupled TES bolometer arrays for CMB polarimetry
We describe the design and performance of polarization selective
antenna-coupled TES arrays that will be used in several upcoming Cosmic
Microwave Background (CMB) experiments: SPIDER, BICEP-2/SPUD. The fully
lithographic polarimeter arrays utilize planar phased-antennas for collimation
(F/4 beam) and microstrip filters for band definition (25% bandwidth). These
devices demonstrate high optical efficiency, excellent beam shapes, and
well-defined spectral bands. The dual-polarization antennas provide
well-matched beams and low cross polarization response, both important for
high-fidelity polarization measurements. These devices have so far been
developed for the 100 GHz and 150 GHz bands, two premier millimeter-wave
atmospheric windows for CMB observations. In the near future, the flexible
microstrip-coupled architecture can provide photon noise-limited detection for
the entire frequency range of the CMBPOL mission. This paper is a summary of
the progress we have made since the 2006 SPIE meeting in Orlando, FL
Galaxy Cluster Pressure Profiles as Determined by Sunyaev Zel'dovich Effect Observations with MUSTANG and Bolocam I: Joint Analysis Technique
We present a technique to constrain galaxy cluster pressure profiles by
jointly fitting Sunyaev-Zel'dovich effect (SZE) data obtained with MUSTANG and
Bolocam for the clusters Abell 1835 and MACS0647. Bolocam and MUSTANG probe
different angular scales and are thus highly complementary. We find that the
addition of the high resolution MUSTANG data can improve constraints on
pressure profile parameters relative to those derived solely from Bolocam. In
Abell 1835 and MACS0647, we find gNFW inner slopes of and , respectively when
and are constrained to 0.86 and 4.67 respectively. The fitted
SZE pressure profiles are in good agreement with X-ray derived pressure
profiles.Comment: 12 pages, 12 figures. Submitted to Ap
- …