25 research outputs found
Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature
Joint arthroplasty registries show an increased rate of aseptic loosening in uncemented acetabular components as compared to cemented acetabular components. Since loosening is associated with particulate wear debris, we postulated that uncemented acetabular components demonstrate a higher polyethylene wear rate than cemented acetabular components in total hip arthroplasty. We performed a systematic review of the peer-reviewed literature, comparing the wear rate in uncemented and cemented acetabular components in total hip arthroplasty. Studies were identified using MEDLINE (PubMed), EMBASE and the Cochrane Central Register of Controlled Trials. Study quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The search resulted in 425 papers. After excluding duplicates and selection based on title and abstracts, nine studies were found eligible for further analysis: two randomised controlled trials, and seven observational studies. One randomised controlled trial found a higher polyethylene wear rate in uncemented acetabular components, while the other found no differences. Three out of seven observational studies showed a higher polyethylene wear in uncemented acetabular component fixation; the other four studies did not show any differences in wear rates. The available evidence suggests that a higher annual wear rate may be encountered in uncemented acetabular components as compared to cemented components
Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50Â years old: results after 12-years follow-up
Background
Congenital hip dysplasia may lead to severe acetabular and femoral abnormalities that can make total hip arthroplasty a challenging procedure. We assessed a series of patients affected by developmental hip dysplasia treated with total hip arthroplasty using cementless tapered stem and here we report the outcomes at long-term follow-up.
Materials and methods
Twenty-eight patients (24 women and 4 men) aged between 44 and 50 years (mean 47 years) were observed. Clinical evaluation was rated with the Harris Hip Score. Radiographic evaluation consisted in standard anteroposterior and axial view radiographs of the hip. According to Croweâs classification, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. All patients were treated with total hip arthroplasty using a cementless tapered stem (Wagner Cone Prosthesis). Six patients were operated bilaterally, with a totally of 34 hips operated. After surgery, the patients were clinically and radiographically checked at 3, 6, and 12 months and yearly thereafter until an average follow-up of 12 years (range 10â14 years).
Results
Average Harris Hip Score was 56 Âą 9 (range 45â69) preoperatively, 90 Âą 9 (range 81â100) 12 months after surgery, and 91 Âą 8 (range 83â100) at last follow-up. Radiographic evaluation demonstrated excellent osteointegration of the implants. Signs of bone resorption were present in 6 hips, nevertheless no evidence of loosening was observed and none of the implants has been revised.
Conclusions
Even in dysplasic femur, the tapered stem allowed adequate stability and orientation of the implant. We consider tapered stem a suitable option for total hip arthroplasty in developmental hip dysplasia, also in case of young patients, thanks to the favourable long-term results