77 research outputs found

    Efficacy and Safety of Alirocumab 150 mg Every 4 Weeks in Patients With Hypercholesterolemia Not on Statin Therapy: The ODYSSEY CHOICE II Study

    Get PDF
    Background - The PCSK9 antibody alirocumab (75 mg every 2 weeks; Q2W) as monotherapy reduced low-density lipoprotein-cholesterol (LDL-C) levels by 47%. Because the option of a monthly dosing regimen is convenient, ODYSSEY CHOICE II evaluated alirocumab 150 mg Q4W in patients with inadequately controlled hypercholesterolemia and not on statin (majority with statin-associated muscle symptoms), receiving treatment with fenofibrate, ezetimibe, or diet alone. Methods and Results - Patients were randomly assigned to placebo, alirocumab 150 mg Q4W or 75 mg Q2W (calibrator arm), with dose adjustment to 150 mg Q2W at week (W) 12 if W8 predefined LDL-C target levels were not met. The primary efficacy endpoint was LDL-C percentage change from baseline to W24. Mean baseline LDL-C levels were 163.9 mg/dL (alirocumab 150 mg Q4W, n= 59), 154.5 mg/dL (alirocumab 75 mg Q2W, n= 116), and 158.5 mg/dL (placebo, n= 58). In the alirocumab 150 mg Q4W and 75 mg Q2W groups (49.1% and 36.0% of patients received dose adjustment, respectively), least-squares mean LDL-C changes from baseline to W24 were -51.7% and -53.5%, respectively (placebo [+ 4.7%]; both groups P< 0.0001 versus placebo). In total, 63.9% and 70.3% of alirocumab-treated patients achieved their LDL-C targets at W24. Treatment-emergent adverse events occurred in 77.6% (alirocumab 150 mg Q4W), 73.0% (alirocumab 75 mg Q2W), and 63.8% (placebo) of patients, with injection-site reactions among the most common treatment-emergent adverse events. Conclusions - Alirocumab 150 mg Q4W can be considered in patients not on statin with inadequately controlled hypercholesterolemia as a convenient option for lowering LDL-C

    Off-pump coronary artery bypass grafting provides complete revascularization with reduced myocardial injury, transfusion requirements, and length of stay: A prospective randomized comparison of two hundred unselected patients undergoing off-pump versus conventional coronary artery bypass grafting

    Get PDF
    AbstractObjective: Retrospective comparisons of selected patients undergoing off-pump versus conventional on-pump coronary artery bypass grafting have yielded inconsistent results and raised concerns about completeness of revascularization in off-pump coronary artery bypass grafting. Methods: Two hundred unselected patients referred for elective primary coronary artery bypass grafting were randomly assigned to undergo off-pump coronary artery bypass grafting with an Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, Minn) or conventional coronary artery bypass grafting with cardiopulmonary bypass by a single surgeon. Revascularization intent determined before random assignment was compared with the revascularization performed. All management followed strict, unbiased, criteria-driven protocols. Patients and nonoperative care providers were blinded to surgical group. Results: Baseline characteristics were similar. The number of grafts performed per patient (mean ± SD 3.39 ± 1.04 for off-pump coronary artery bypass grafting, 3.40 ± 1.08 for conventional coronary artery bypass grafting) and the index of completeness of revascularization (number of grafts performed/number of grafts intended, 1.00 ± 0.18 for off-pump coronary artery bypass grafting, 1.01 ± 0.09 for conventional coronary artery bypass grafting) were similar. Likewise, the index of completeness of revascularization was similar between groups for the lateral wall. Combined hospital and 30-day mortalities and stroke rates were similar. Postoperative myocardial serum enzyme measures were significantly lower after off-pump coronary artery bypass grafting, suggesting less myocardial injury. Adjusted postoperative thromboelastogram indices, fibrinogen, international normalized ratio, and platelet levels all showed significantly less coagulopathy after off-pump coronary artery bypass grafting. Patients undergoing off-pump coronary artery bypass grafting received fewer units of blood, were more likely to avoid transfusion altogether, and had a higher hematocrit at discharge. Cardiopulmonary bypass was an independent predictor of transfusion (odds ratio 2.42, P =.0073) by multivariate analysis. More patients undergoing off-pump coronary artery bypass grafting were extubated in the operating room and within 4 hours. Postoperative length of stay (in days) was shorter for off-pump coronary artery bypass grafting (5.1 ± 6.5 for off-pump coronary artery bypass grafting, 6.1 ± 8.2 for conventional coronary artery bypass grafting, P =.005 by Wilcoxon test). One patient (in the conventional coronary artery bypass grafting group) required angioplasty for graft closure within 30 days. Conclusions: When compared with conventional coronary artery bypass grafting with cardiopulmonary bypass, off-pump coronary artery bypass grafting achieved similar completeness of revascularization, similar in-hospital and 30-day outcomes, shorter length of stay, reduced transfusion requirement, and less myocardial injury.J Thorac Cardiovasc Surg 2003;125:797-80

    Off-pump coronary artery bypass grafting provides complete revascularization with reduced myocardial injury, transfusion requirements, and length of stay: A prospective randomized comparison of two hundred unselected patients undergoing off-pump versus conventional coronary artery bypass grafting

    Get PDF
    AbstractObjective: Retrospective comparisons of selected patients undergoing off-pump versus conventional on-pump coronary artery bypass grafting have yielded inconsistent results and raised concerns about completeness of revascularization in off-pump coronary artery bypass grafting. Methods: Two hundred unselected patients referred for elective primary coronary artery bypass grafting were randomly assigned to undergo off-pump coronary artery bypass grafting with an Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, Minn) or conventional coronary artery bypass grafting with cardiopulmonary bypass by a single surgeon. Revascularization intent determined before random assignment was compared with the revascularization performed. All management followed strict, unbiased, criteria-driven protocols. Patients and nonoperative care providers were blinded to surgical group. Results: Baseline characteristics were similar. The number of grafts performed per patient (mean ± SD 3.39 ± 1.04 for off-pump coronary artery bypass grafting, 3.40 ± 1.08 for conventional coronary artery bypass grafting) and the index of completeness of revascularization (number of grafts performed/number of grafts intended, 1.00 ± 0.18 for off-pump coronary artery bypass grafting, 1.01 ± 0.09 for conventional coronary artery bypass grafting) were similar. Likewise, the index of completeness of revascularization was similar between groups for the lateral wall. Combined hospital and 30-day mortalities and stroke rates were similar. Postoperative myocardial serum enzyme measures were significantly lower after off-pump coronary artery bypass grafting, suggesting less myocardial injury. Adjusted postoperative thromboelastogram indices, fibrinogen, international normalized ratio, and platelet levels all showed significantly less coagulopathy after off-pump coronary artery bypass grafting. Patients undergoing off-pump coronary artery bypass grafting received fewer units of blood, were more likely to avoid transfusion altogether, and had a higher hematocrit at discharge. Cardiopulmonary bypass was an independent predictor of transfusion (odds ratio 2.42, P =.0073) by multivariate analysis. More patients undergoing off-pump coronary artery bypass grafting were extubated in the operating room and within 4 hours. Postoperative length of stay (in days) was shorter for off-pump coronary artery bypass grafting (5.1 ± 6.5 for off-pump coronary artery bypass grafting, 6.1 ± 8.2 for conventional coronary artery bypass grafting, P =.005 by Wilcoxon test). One patient (in the conventional coronary artery bypass grafting group) required angioplasty for graft closure within 30 days. Conclusions: When compared with conventional coronary artery bypass grafting with cardiopulmonary bypass, off-pump coronary artery bypass grafting achieved similar completeness of revascularization, similar in-hospital and 30-day outcomes, shorter length of stay, reduced transfusion requirement, and less myocardial injury.J Thorac Cardiovasc Surg 2003;125:797-80

    Neural Network in Modeling Glucose-Insulin Behavior

    No full text
    corecore