1,443 research outputs found

    Changes in Dry State Hemoglobin over Time Do Not Increase the Potential for Oxidative DNA Damage in Dried Blood

    Get PDF
    BACKGROUND: Hemoglobin (Hb) is the iron-containing oxygen transport protein present in the red blood cells of vertebrates. Ancient DNA and forensic scientists are particularly interested in Hb reactions in the dry state because both regularly encounter aged, dried bloodstains. The DNA in such stains may be oxidatively damaged and, in theory, may be deteriorated by the presence of Hb. To understand the nature of the oxidative systems potentially available to degrade DNA in the presence of dried Hb, we need to determine what molecular species Hb forms over time. These species will determine what type of iron (i.e. Fe(2+)/Fe(3+)/Fe(4+)) is available to participate in further chemical reactions. The availability of "free" iron will affect the ability of the system to undergo Fenton-type reactions which generate the highly reactive hydroxyl radical (OH*). The OH* can directly damage DNA. METHODOLOGY/PRINCIPAL FINDINGS: Oxygenated Hb (oxyHb) converts over time to oxidized Hb (metHb), but this happens more quickly in the dry state than in the hydrated state, as shown by monitoring stabilized oxyHb. In addition, dry state oxyHb converts into at least one other unknown species other than metHb. Although "free" iron was detectable as both Fe(2+) and Fe(3+) in dry and hydrated oxyHb and metHb, the amount of ions detected did not increase over time. There was no evidence that Hb becomes more prone to generating OH* as it ages in either the hydrated or dry states. CONCLUSIONS: The Hb molecule in the dried state undergoes oxidative changes and releases reactive Fe(II) cations. These changes, however, do not appear to increase the ability of Hb to act as a more aggressive Fenton reagent over time. Nevertheless, the presence of Hb in the vicinity of DNA in dried bloodstains creates the opportunity for OH*-induced oxidative damage to the deoxyribose sugar and the DNA nucleobases

    eBank UK: linking research data, scholarly communication and learning

    No full text
    This paper includes an overview of the changing landscape of scholarly communication and describes outcomes from the innovative eBank UK project, which seeks to build links from e-research through to e-learning. As introduction, the scholarly knowledge cycle is described and the role of digital repositories and aggregator services in linking data-sets from Grid-enabled projects to e-prints through to peer-reviewed articles as resources in portals and Learning Management Systems, are assessed. The development outcomes from the eBank UK project are presented including the distributed information architecture, requirements for common ontologies, data models, metadata schema, open linking technologies, provenance and workflows. Some emerging challenges for the future are presented in conclusion

    Manipulating mentors' assessment decisions: Do underperforming student nurses use coercive strategies to influence mentors' practical assessment decisions?

    Get PDF
    There is growing evidence of a culture of expectation among nursing students in Universities which leads to narcissistic behaviour. Evidence is growing that some student nurses are disrespectful and rude towards their university lecturers. There has been little investigation into whether they exhibit similar behaviour towards their mentors during practical placements, particularly when they, the students, are not meeting the required standards for practice. This paper focuses on adding to the evidence around a unique finding ��� that student nurses can use coercive and manipulative behaviour to elicit a successful outcome to their practice learning assessment (as noted in Hunt et al. (2016, p 82)). Four types of coercive student behaviour were identified and classified as: ingratiators, diverters, disparagers and aggressors, each of which engendered varying degrees of fear and guilt in mentors. The effects of each type of behaviour are discussed and considered in the light of psychological contracts. Mechanisms to maintain effective working relationships between student nurses and mentors and bolster the robustness of the practical assessment process under such circumstances are discussed

    Redesigning metal interference screws can improve ease of insertion while maintaining fixation of soft-tissue anterior cruciate ligament reconstruction grafts

    Get PDF
    Purpose: To compare the fixation strength and loads on insertion of a titanium alloy interference screw with a modified tip against a conventional titanium interference screw. Methods: Slippage of bovine digital extensor tendons (as substitutes for human tendon grafts) under cyclic loading and interference fixation strength under a pullout test were recorded in 10 cadaveric knees, with 2 tunnels drilled in each femur and tibia to provide pair-wise comparisons between the modified-tip screw (MS) and conventional screw (CS). To analyze screw insertion, 10 surgeons blindly inserted pairs of the MS and CS into bone-substitute blocks (with polyester shoelaces as graft substitutes), with insertion loads measured using a force/torque sensor. Results: No differences were found between the MS and CS either in graft slippage from the femur (P = .661) or tibia (P = .950) or in ultimate load to failure from the femur (P = .952) or tibia (P = .126). On insertion, the MS required less axial force application (78 ± 38 N, P = .001) and fewer attempted turns (2 ± 1, P < .001) to engage with the bone tunnel than the CS (99 ± 43 N and 4 ± 4, respectively). In 90% of the paired insertion tests, the screw identified by the surgeon as being easier to initially insert was the MS. Conclusions: The MS was found to be easier to engage with the bone tunnel and initially insert than the CS while still achieving similar immediate postsurgical fixation strength. Clinical Relevance: The study shows that screw designs can be improved to ease insertion into a bone tunnel, which should reduce any likelihood of ligament reconstruction graft damage

    Directing Differentiation of Pluripotent Stem Cells Toward Retinal Pigment Epithelium Lineage

    Get PDF
    Development of efficient and reproducible conditions for directed differentiation of pluripotent stem cells into specific cell types is important not only to understand early human development but also to enable more practical applications, such as in vitro disease modeling, drug discovery, and cell therapies. The differentiation of stem cells to retinal pigment epithelium (RPE) in particular holds promise as a source of cells for therapeutic replacement in age-related macular degeneration. Here we show development of an efficient method for deriving homogeneous RPE populations in a period of 45 days using an adherent, monolayer system and defined xeno-free media and matrices. The method utilizes sequential inhibition and activation of the Activin and bone morphogenetic protein signaling pathways and can be applied to both human embryonic stem cells and induced pluripotent stem cells as the starting population. In addition, we use whole genome transcript analysis to characterize cells at different stages of differentiation that provides further understanding of the developmental dynamics and fate specification of RPE. We show that with the described method, RPE develop through stages consistent with their formation during embryonic development. This characterization- together with the absence of steps involving embryoid bodies, three-dimensional culture, or manual dissections, which are common features of other protocols-makes this process very attractive for use in research as well as for clinical applications. SIGNIFICANCE: This report describes a novel method of directed differentiation to generate retinal pigment epithelium (RPE) cells from pluripotent stem cells. The employed method is based on adherent monolayer culture using xeno-free conditions and manipulation of the Activin and bone morphogenetic protein signaling pathway using small molecules and recombinant proteins. Whole genome microarray analysis was performed to characterize the differentiation process and understand the developmental path of RPE generation in vitro. This method can be applied for generation of RPE for research as well as for clinical applications

    Acoustic localisation of wildlife with low-cost equipment: Lower sensitivity, but no loss of precision

    Get PDF
    Abstract Context Synchronised acoustic recorders can be used as a non-invasive tool to detect and localise sounds of interest, including vocal wildlife and anthropogenic sounds. Due to the high cost of commercial synchronised recorders, acoustic localisation has typically been restricted to small or well funded surveys. Recently, low-cost acoustic recorders have been developed, but until now their efficacy has not been compared with higher specification recorders. Aims The present study aimed to compare the efficacy of a newly developed low-cost recorder, the Conservation at Range through Audio Classification and Localisation (CARACAL), with an established, high-end recorder, the Wildlife Acoustics Song Meter (SM). Methods Four recorders of each type were deployed in a paired set-up across five nights in Wisconsin, USA. The recordings allowed for manual identification of domestic dog (Canis familiaris), grey wolf (Canis lupus), coyote (Canis latrans) and barred owl (Strix varia) calls, and then the ability of each recorder type to detect and localise the vocalising animals was compared. Key results The CARACALs were less sensitive, detecting only 47.5% of wolf, 55% of coyote, 65% of barred owl and 82.5% of dog vocalisations detected by the paired SMs. However, when the same vocalisations were detected on both recorders, localisation was comparable, with no significant difference in the precision or maximum detection ranges. Conclusions Low-cost recording equipment can be used effectively for acoustic localisation of both wild and domestic animals. However, the lower sensitivity of the CARACALs means that a denser network of these recorders would be needed to achieve the same efficacy as the SMs. Deploying a greater number of cheaper recorders increases the labour time in the field and the quantity of data to process and store. Thus, there is a trade-off between cost and time to be considered. Implications The ability to use low-cost recorders for acoustic localisation provides new avenues for tracking, managing and researching a wide range of wildlife species. Presently, CARACALs are more suited to monitoring species that have small home ranges and high amplitude vocalisations, and for when a large time investment for in situ equipment checks and data processing is feasible.Christine Stevens Wildlife Award from the Animal Welfare Institut
    corecore