2,323 research outputs found

    AFD2-D-GEN-EG-0001 Environmental Baseline Survey Report

    Get PDF
    An Environmental Baseline Investigation was performed at AF Miljøbase Vats in Rogaland, Southwest Norway. The contamination of seafloor sediments, well-water and soil was analyzed, and the occurrence of anthropogenic debris and biological state at the bottom outside the facility was investigated with an ROV. The results show that the sediments are contaminated with TBT (SFT Class IV, TA-2229/2007) and PAH (Class II), but not at a higher level than was previously shown. The remaining components (As, Ba, Cd, Co, Cr, Cu, Hg, Mo, Ni, P, Pb, V, Zn, PCBs, 5CB, alpha- and gamma-HCH, HCB, OCS, DDE, DDD, MBT, DBT, MPT, DPT and TPT) in sediments close to the site were either in Class I (background), not included in TA-2229/2007, or not detected. This includes mercury that leaked into the bays between 2004 and 2006. The well-water was not contaminated, whereas soil samples were slightly contaminated with zinc and arsenic just above the SFT norm for sensitive land use. Large rocks and metallic debris are found along the shore, smothered with rock-dust due to the recent expansion of the quay areas. The biological state is typical for a quay area in this region.AF Decom Offshor

    A Limit on the Polarized Anisotropy of the Cosmic Microwave Background at Subdegree Angular Scales

    Full text link
    A ground-based polarimeter, PIQUE, operating at 90 GHz has set a new limit on the magnitude of any polarized anisotropy in the cosmic microwave background. The combination of the scan strategy and full width half maximum beam of 0.235 degrees gives broad window functions with average multipoles, l = 211+294-146 and l = 212+229-135 for the E- and B-mode window functions, respectively. A joint likelihood analysis yields simultaneous 95% confidence level flat band power limits of 14 and 13 microkelvin on the amplitudes of the E- and B-mode angular power spectra, respectively. Assuming no B-modes, a 95% confidence limit of 10 microkelvin is placed on the amplitude of the E-mode angular power spectrum alone.Comment: 4 pages, 3 figures, submitted to Astrophysical Journal Letter

    Measurements of Anisotropy in the Cosmic Microwave Background Radiation at 0.5 Degree Angular Scales Near the Star Gamma Ursae Minoris

    Full text link
    We present results from a four frequency observation of a 6 x 0.6 degree strip of the sky centered near the star Gamma Ursae Minoris during the fourth flight of the Millimeter-wave Anisotropy eXperiment (MAX). The observation was made with a 1.4 degree peak-to-peak sinusoidal chop in all bands. The FWHM beam sizes were 0.55 +/- 0.05 degrees at 3.5 cm-1 and 0.75 +/-0.05 degrees at 6, 9, and 14 cm-1. During this observation significant correlated structure was observed at 3.5, 6 and 9 cm-1 with amplitudes similar to those observed in the GUM region during the second and third flights of MAX. The frequency spectrum is consistent with CMB and inconsistent with thermal emission from interstellar dust. The extrapolated amplitudes of synchrotron and free-free emission are too small to account for the amplitude of the observed structure. If all of the structure is attributed to CMB anisotropy with a Gaussian autocorrelation function and a coherence angle of 25', then the most probable values of DeltaT/TCMB in the 3.5, 6, and 9 cm-1 bands are 4.3 (+2.7, -1.6) x 10-5, 2.8 (+4.3, -1.1) x 10-5, and 3.5 (+3.0, -1.6) x 10-5 (95% confidence upper and lower limits), respectively.Comment: 16 pages, postscrip

    Measurements of Anisotropy in the Cosmic Microwave Background Radiation at Degree Angular Scales Near the Stars Sigma Hercules and Iota Draconis

    Get PDF
    We present results from two four-frequency observations centered near the stars Sigma Hercules and Iota Draconis during the fourth flight of the Millimeter-wave Anisotropy eXperiment (MAX). The observations were made of 6 x 0.6-degree strips of the sky with 1.4-degree peak to peak sinusoidal chop in all bands. The FWHM beam sizes were 0.55+/-0.05 degrees at 3.5 cm-1 and a 0.75+/-0.05 degrees at 6, 9, and 14 cm-1. Significant correlated structures were observed at 3.5, 6 and 9 cm-1. The spectra of these signals are inconsistent with thermal emission from known interstellar dust populations. The extrapolated amplitudes of synchrotron and free-free emission are too small to account for the amplitude of the observed structures. If the observed structures are attributed to CMB anisotropy with a Gaussian autocorrelation function and a coherence angle of 25', then the most probable values are DT/TCMB = (3.1 +1.7-1.3) x 10^-5 for the Sigma Hercules scan, and DT/TCMB = (3.3 +/- 1.1) x 10^-5 for the Iota Draconis scan (95% confidence upper and lower limits). Finally a comparison of all six MAX scans is presented.Comment: 13 pages, postscript file, 2 figure

    On the eigenproblems of PT-symmetric oscillators

    Full text link
    We consider the non-Hermitian Hamiltonian H= -\frac{d^2}{dx^2}+P(x^2)-(ix)^{2n+1} on the real line, where P(x) is a polynomial of degree at most n \geq 1 with all nonnegative real coefficients (possibly P\equiv 0). It is proved that the eigenvalues \lambda must be in the sector | arg \lambda | \leq \frac{\pi}{2n+3}. Also for the case H=-\frac{d^2}{dx^2}-(ix)^3, we establish a zero-free region of the eigenfunction u and its derivative u^\prime and we find some other interesting properties of eigenfunctions.Comment: 21pages, 9 figure

    Compact Pulsed-Power System for Transient Plasma Ignition

    Get PDF
    The article of record as published may be found at http://dx.doi.org10.1109/TPS.2009.2024672The use of a compact solid-state pulse generator and compact igniters for transient plasma ignition in a pulse detonation engine (PDE) is reported and compared with previous results using a pseudospark pulse generator and threaded rod electrode. Transient plasma is attractive as a technology for the ignition of PDEs and other engine applications because it results in reductions in ignition delay and has been shown to ignite leaner mixtures which allows for lower specific fuel consumption, high-repetition rates, high-altitude operation, and reduced NOx emissions. It has been applied effectively to the ignition of PDEs as well as internal combustion engines. Nonequilibrium transient plasma discharges are produced by applying high-voltage nanosecond pulses that generate streamers, which generate radicals and other electronically excited species over a volume. The pulse generator used is in this experiment is capable of delivering 180 mJ into a 200-Ω load, in the form of a 60-kV 12-ns pulse. Combined with transient plasma igniters comparable with traditional spark plugs, the system was successfully tested in a PDE, resulting in similar ignition delays to those previously reported while using a smaller electrode geometry and delivering an order of magnitude less energy.Office of Naval Researc

    Temperature inversion symmetry in the Casimir effect with an antiperiodic boundary condition

    Full text link
    We present explicitly another example of a temperature inversion symmetry in the Casimir effect for a nonsymmetric boundary condition. We also give an interpretation for our result.Comment: 4 page
    corecore