30 research outputs found

    Common Pacemaker Problems: Lead and Pocket Complications

    Get PDF

    The thrombus image in the huge left atrial appendage

    Get PDF

    Lithium intoxication causing ST segment elevation and wandering atrial rhythms in an elderly patient

    Get PDF
    Lithium overdoses causing cardiotoxicity are uncommon and electrocardiographic changes suggesting myocardial ischemia are rare. However, some authors have specifically reported the occurrence of ischemic electrocardiography changes due to a lithium overdose. This paper describes a case where electrocardiography changes mimic inferior myocardial infarction during the course of chronic lithium treatment in an elderly patient. The patient’s electrocardiography changes were partially resolved after hemodialysis. (Cardiol J 2009; 17, 4: 404-407

    The Association between Myocardial Iron Load and Ventricular Repolarization Parameters in Asymptomatic Beta-Thalassemia Patients

    Get PDF
    Previous studies have demonstrated impaired ventricular repolarization in patients with β-TM. However, the effect of iron overload with cardiac T2* magnetic resonance imaging (MRI) on cardiac repolarization remains unclear yet. We aimed to examine relationship between repolarization parameters and iron loading using cardiac T2* MRI in asymptomatic β-TM patients. Twenty-two β-TM patients and 22 age- and gender-matched healthy controls were enrolled to the study. From the 12-lead surface electrocardiography, regional and transmyocardial repolarization parameters were evaluated manually by two experienced cardiologists. All patients were also undergone MRI for cardiac T2* evaluation. Cardiac T2* score <20 msec was considered as iron overload status. Of the QT parameters, QT duration, corrected QT interval, and QT peak duration were significantly longer in the β-TM group compared to the healthy controls. Tp − Te and Tp − Te dispersions were also significantly prolonged in β-TM group compared to healthy controls. (Tp − Te)/QT was similar between groups. There was no correlation between repolarization parameters and cardiac T2* MRI values. In conclusion, although repolarization parameters were prolonged in asymptomatic β-TM patients compared with control, we could not find any relation between ECG findings and cardiac iron load

    Fluoroless catheter ablation of atrial fibrillation: integration of intracardiac echocardiography and cartosound module

    Get PDF
    Objective: To evaluate the feasibility, safety, and clinical efficacy of non-fluoroscopic radiofrequency catheter ablation of atrial fibrillation (AF) in comparison to traditional fluoroscopy-guided ablation in a local Canadian community cohort. Methods: We retrospectively studied consecutive patients with paroxysmal and persistent AF undergoing pulmonary vein isolation (PVI) guided by intracardiac echocardiography (ICE) and Carto system (CartoSound module). ICE-guided PVI without fluoroscopy (Zero-fluoro group) was performed in 116 patients, and conventional fluoroscopy-guided PVI (Traditional group) was performed in 131 patients. Results: Two hundred and forty-seven patients with AF (60.7% male; mean age: 62.2 ± 10.6 years; paroxysmal AF =63.1%) who underwent PVI were studied. Mean procedure times were similar between both groups (136.8±33.4 minutes in the zero-fluoro group vs. 144.3±44.9 minutes in the traditional group; p=0.2). Acute PVI was achieved in all patients. Survival from early AF recurrence was 85% and 81% in the zero-fluoro and traditional groups, respectively (p = 0.06). Survival from late AF recurrence (12-months) between the zero-fluoro and traditional groups was also similar (p=0.1). Moreover, there were no significant differences between complication rates, including hematoma (p = 0.2) and tamponade (p = 1),between both groups. Conclusions: Zero-fluoroscopy ICE and CartoSound-guided AF ablation may be safe and feasible in patients undergoing PVI compared to conventional fluoroscopy-guided ablation

    Association of electrocardiographic markers with myocardial fibrosis as assessed by cardiac magnetic resonance in different clinical settings

    Get PDF
    BACKGROUND Cardiac magnetic resonance (CMR) is a unique tool for non-invasive tissue characterization, especially for identifying fibrosis. AIM To present the existing data regarding the association of electrocardiographic (ECG) markers with myocardial fibrosis identified by CMR - late gadolinium enhancement (LGE). METHODS A systematic search was performed for identifying the relevant studies in Medline and Cochrane databases through February 2021. In addition, we conducted a relevant search by Reference Citation Analysis (RCA) (https://www.referencecitationanalysis.com). RESULTS A total of 32 studies were included. In hypertrophic cardiomyopathy (HCM), fragmented QRS (fQRS) is related to the presence and extent of myocardial fibrosis. fQRS and abnormal Q waves are associated with LGE in ischemic cardiomyopathy patients, while fQRS has also been related to fibrosis in myocarditis. Selvester score, abnormal Q waves, and notched QRS have also been associated with LGE. Repolarization abnormalities as reflected by increased Tp-Te, negative T-waves, and higher QT dispersion are related to myocardial fibrosis in HCM patients. In patients with Duchenne muscular dystrophy, a significant correlation between fQRS and the amount of myocardial fibrosis as assessed by LGE-CMR was observed. In atrial fibrillation patients, advanced inter-atrial block is defined as P-wave duration ≥ 120 ms, and biphasic morphology in inferior leads is related to left atrial fibrosis. CONCLUSION Myocardial fibrosis, a reliable marker of prognosis in a broad spectrum of cardiovascular diseases, can be easily understood with an easily applicable ECG. However, more data is needed on a specific disease basis to study the association of ECG markers and myocardial fibrosis as depicted by CMR
    corecore