19 research outputs found

    Safety and effectiveness of a new electrical detachable microcoil for embolization of hemorrhoidal disease, November 2020–December 2021: results of a prospective study

    Get PDF
    Purpose: The purpose of this study was to prospectively evaluate the efficacy and safety of a new, bare platinum, detachable microcoil as a metallic embolization agent in the treatment of hemorrhoidal disease. Material and Methods: This prospective single-center study evaluated a new, bare platinum, electrical, detachable microcoil (Prestige plus coil (Balt Montmorency France)) for use in vascular embolization in patients with hemorrhoidal disease. Between January 2020 and January 2021, 24 embolization procedures were performed in 21 patients (12 males, 9 females; mean age 44.3 ± 7.3). The inclusion criteria were: (a) participants with grade I, II and III hemorrhoidal disease on the Goligher classification; (b) patients older than 18 years of age with a score of greater than 4 on the French bleeding score (FBS) scale; (c) patients with scores greater than 2 on the scale of discomfort proposed by Tradi and Farfallah. (d) patients who underwent treatment that included the use of the new novel coil (Prestige plus coil (Balt)) as an embolic material. The exclusion criteria were participants who failed to provide informed consent and participants diagnosed with rectal bleeding due to other causes (cancer, fissures or others). Participants with severe renal insufficiency, non-correctable coagulation abnormalities and adverse reactions to the contrast medium not correctable with medication were also excluded. The symptoms, technical aspects, the transarterial approach, clinical and technical success complications and short-term outcomes were assessed. Results: Technical success was obtained in 100% of the cases. Seventeen (80.9%) patients experienced improvements in their hemorrhoidal disease. The VAS and QL scores improved by 4 and 1.5 points (81.2% and 87.5%), respectively, after embolization (pV: 0001). Three (14.2%) patients underwent a second embolization due to rebleeding. One patient (4.7%) underwent surgery. No major complications were observed. Three patients had minor complications. The assessment of subjective post-treatment symptoms and QL surveys showed significant differences from the baseline survey. Likewise, the measurement of the degree of satisfaction using a telephone survey at 12 months revealed a high degree of patient satisfaction over 10 points (mean 8.3 ± 1.1). Conclusions: The present study demonstrates that the use of the new, platinum, detachable, electrical microcoil is safe and well-tolerated in the treatment of hemorrhoidal disease. Key points: Catheter-directed hemorrhoidal dearterialization (CDHD) is the procedure of embolization with embolic agents for the treatment of internal hemorrhoids. CDHD is a simple and safe procedure that is accepted by patients and preserves the anal sphincter; it presents few complications when metal devices or microspheres are used as embolic agents. As the recommended embolization agent in treatments, the Prestige electrical, detachable coil is a safe, easy-to-use and effective arterial embolic device

    TIPS treatment in a patient with severe lower gastrointestinal bleeding with a misdiagnosis of cirrhotic portal hypertension.

    Get PDF
    Abernethy malformation is a rare abnormal embryological development of splanchnic venous system characterised by the presence of a congenital extrahepatic portosystemic shunt. We present a rare case of an adult male patient that was admitted with severe lower gastrointestinal bleeding, requiring multiple blood transfusions. The patient's medical history and the laboratory tests performed led to the misdiagnosis of a congenital Abernethy malformation. We present a rare case, discussing the reasons for the misdiagnosis and we conclude that management of clinical data and imaging are highly important to discard these types of congenital malformations that can mimic a portal hypertension condition

    Phosphoproteomic Landscape of AML Cells Treated with the ATP-Competitive CK2 Inhibitor CX-4945

    Get PDF
    Casein kinase 2 (CK2) regulates a plethora of proteins with pivotal roles in solid and hematological neoplasia. Particularly, in acute myeloid leukemia (AML) CK2 has been pointed as an attractive therapeutic target and prognostic marker. Here, we explored the impact of CK2 inhibition over the phosphoproteome of two cell lines representing major AML subtypes. Quantitative phosphoproteomic analysis was conducted to evaluate changes in phosphorylation levels after incubation with the ATP-competitive CK2 inhibitor CX-4945. Functional enrichment, network analysis, and database mining were performed to identify biological processes, signaling pathways, and CK2 substrates that are responsive to CX-4945. A total of 273 and 1310 phosphopeptides were found differentially modulated in HL-60 and OCI-AML3 cells, respectively. Despite regulated phosphopeptides belong to proteins involved in multiple biological processes and signaling pathways, most of these perturbations can be explain by direct CK2 inhibition rather than off-target effects. Furthermore, CK2 substrates regulated by CX-4945 are mainly related to mRNA processing, translation, DNA repair, and cell cycle. Overall, we evidenced that CK2 inhibitor CX-4945 impinge on mediators of signaling pathways and biological processes essential for primary AML cells survival and chemosensitivity, reinforcing the rationale behind the pharmacologic blockade of protein kinase CK2 for AML targeted therapy

    Spanish multicenter real – life registry of retrievable vena cava filters (REFiVeC)

    Get PDF
    Background The treatment of venous thromboembolic disease the treatment of choice is systemic anticoagulation. However, the interruption of the inferior vena cava with filters has been recommended when anticoagulation fails or there is a contraindication. Due to the rising inferior vena cava filter (IVCF) complications, physicians are encouraged to retrieve them when there is no longer recommended. In daily practice, it may be a difficult close follow-up of these patients. In this study, the primary objective was to evaluate the IVCF retrieval rate of all implanted filters in a Spanish registry. Secondary objectives were to analyze the causes of failed retrieval, procedure-related complications, and outcomes at a 12-month follow-up. Results Three hundred fifty-six vena cava filters were implanted in 355 patients. The types of filter were: Gunther Tulip (Cook Medical) 160 (44.9%), Optease (Cordis) 77 (21.6%), Celect (Cook Medical) 49 (13, 7%), Aegisy (Lifetech Scientific) 33 (9.2%), Option ELITE (Argon Medical devices) 16 (4.4%), Denali filter (BD Bard) 11 (3.08%), ALN filter (ALN) 10 (2.8%). Removal was achieved in 274/356 (76,9%). eighty-two (23,1%) IVCF were not retrieved due to the following: 41 (11,5%) patients required ongoing filtration, 24 IVCF (6,7%) patients died before retrieval, and 17 (4,7%) impossibility of retrieval because of a tilted and embedded filter apex. There were no major complications observed. Conclusions The global retrieval rate of IVCF was achieved in 76.9%, and the adjusted retrieval rate was of 94.15% with no major complications. IVCF tilting was associated with failure of filter removal in less than 5% of cases. This study demonstrates that the retrieval procedure of IVCF is controlled by the clinician and not by the interventional radiologist

    Ibero-American Society of Interventionism (SIDI) and the Spanish Society of Vascular and Interventional Radiology (SERVEI) Standard of Practice (SOP) for the management of inferior Vena Cava filters in the treatment of acute venous Thromboembolism

    Get PDF
    Objectives: to present an interventional radiology standard of practice on the use of inferior vena cava filters (IVCFs) in patients with or at risk to develop venous thromboembolism (VTE) from the Iberoamerican Interventional Society (SIDI) and Spanish Vascular and Interventional Radiology Society (SERVEI). Methods: a group of twenty-two interventional radiologist experts, from the SIDI and SERVEI societies, attended online meetings to develop a current clinical practice guideline on the proper indication for the placement and retrieval of IVCFs. A broad review was undertaken to determine the participation of interventional radiologists in the current guidelines and a consensus on inferior vena cava filters. Twenty-two experts from both societies worked on a common draft and received a questionnaire where they had to assess, for IVCF placement, the absolute, relative, and prophylactic indications. The experts voted on the different indications and reasoned their decision. Results: a total of two-hundred-thirty-three articles were reviewed. Interventional radiologists participated in the development of just two of the eight guidelines. The threshold for inclusion was 100% agreement. Three absolute and four relative indications for the IVCF placement were identified. No indications for the prophylactic filter placement reached the threshold. Conclusion: interventional radiologists are highly involved in the management of IVCFs but have limited participation in the development of multidisciplinary clinical practice guidelines

    Desórdenes venosos pélvicos en la mujer debidos a varices pélvicas. Tratamiento mediante embolización. Breve revisión

    Get PDF
    El síndrome de congestión pélvica (SCP), actualmente englobado en los “desordenes venosos pélvicos en la mujer (DVPm) debidos a varices pélvicas”1 es una condición patológica que sufre un importante porcentaje de mujeres, y generalmente, se caracteriza por dolor abdominal que dura al menos 6 meses. Existen diferentes tipos de tratamientos, pero el más extendido es la embolización de las venas varicosas pélvicas. Presentamos una pequeña revisión del tema y aportamos nuestra experiencia de casi 20 años con más de 500 pacientes. La embolización de las varices pélvicas parece ser un tratamiento seguro y relativamente efectivo en la gran mayoría de las mujeres

    COVID-19 Outbreak: Infection Control and Management Protocol for Vascular and Interventional Radiology Departments-Consensus Document.

    No full text
    COVID-19 (SARS-CoV-2 virus) pandemic was recently declared by the WHO as a global health emergency. A group of interventional radiology senior experts developed a consensus document for infection control and management of patients with COVID-19 in interventional radiology (IR) departments. This consensus statement has been brought together at short notice with the help of different protocols developed by governmental entities and scientific societies to be adapted to the current reality and needs of IR Departments. Recommendations are the specific strategies to follow in IR departments, preventive measures and regulations, step by step for donning and doffing personal protective equipment, specific IR procedures which can not be delayed, and aerosol-generating procedures in IR with COVID-19 patients. It is advisable with this document to be adapted to local workplace policies
    corecore