2 research outputs found

    First international new intravascular rigid-flex endovascular stent study (FINESS): Clinical and angiographic results after elective and urgent stent implantation

    Get PDF
    Objectives. The purpose of this study was to determine the feasibility, safety and efficacy of elective and urgent deployment of the new intravascular rigid-flex (NIR) stent in patients with coronary artery disease. Background. Stent implantation has been shown to be effective in the treatment of focal, new coronary stenoses and in restoring coronary flow after coronary dissection and abrupt vessel closure. However, currently available stents either lack flexibility, hindering navigation through tortuous arteries, or lack axial strength, resulting in suboptimal scaffolding of the vessel. The unique transforming multicellular design of the NIR stent appears to provide both longitudinal flexibility and radial strength. Methods. NIR stent implantation was attempted in 255 patients (341 lesions) enrolled prospectively in a multicenter international registry from December 1995 through March 1996. Nine-, 16- and 32-mm long NIR stents were manually crimped onto coronary balloons and deployed in native coronary (94%) and saphenous vein graft (6%) lesions. Seventy-four percent of patients underwent elective stenting for primary or restenotic lesions, 21% for a suboptimal angioplasty result and 5% for threatened or abrupt vessel closure. Fifty-two percent of patients presented with unstable angina, 48% had a previous myocardial infarction, and 45% had multivessel disease. Coronary lesions were frequently complex, occurring in relatively small arteries (mean [±SD] reference diameter 2.8 ± 0.6 mm). Patients were followed up for 6 months for the occurrence of major adverse cardiovascular events. Results. Stent deployment was accomplished in 98% of lesions. Mean minimal lumen diameter increased by 1.51 ± 0.51 mm (from 1.09 ± 0.43 mm before to 2.60 ± 0.50 mm after the procedure). Mean percent diameter stenosis decreased from 61 ± 13% before to 17 ± 7% after intervention. A successful interventional procedure with <50% diameter stenosis of all treatment site lesions and no major adverse cardiac events within 30 days occurred in 95% of patients. Event-free survival at 6 months was 82%. Ninety-four percent of surviving patients were either asymptomatic or had mild stable angina at 6 month follow-up. Conclusions. Despite unfavorable clinical and angiographic characteristics of the majority of patients enrolled, the acute angiographic results and early clinical outcome after NIR stent deployment were very promising. A prospective, randomized trial comparing the NIR stent with other currently available stents appears warranted

    Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL)

    Get PDF
    BACKGROUND: Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, approximately 40% of the vessels were small (<2.5 mm). The present study evaluates the relationship between angiographic outcome and vessel diameter for sirolimus-eluting stents. METHODS AND RESULTS: Patients were randomized to receive either an 18-mm bare metal Bx VELOCITY (BS group, n=118), or a sirolimus-eluting Bx VELOCITY stent (SES group, n=120). Subgroups were stratified into tertiles according to their reference diameter (RD; stratum I, RD 2.84 mm). At 6-month follow-up, the restenosis rate in the SES group was 0% in all strata (versus 35%, 26%, and 20%, respectively, in the BS group). In-stent late loss was 0.01+/-0.25 versus 0.80+/-0.43 mm in stratum I, 0.01+/-0.38 versus 0.88+/-0.57 mm in stratum II, and -0.06+/-0.35 versus 0.74+/-0.57 mm in stratum III (SES versus BS). In SES, the minimal lumen diameter (MLD) remained unchanged (Delta -0.72 to 0.72 mm) in 97% of the lesions and increased (=late gain, DeltaMLD <-0.72 mm) in 3% of the lesions. Multivariate predictors for late loss were treatment allocation (P<0.001) and postprocedural MLD (P= 0.008). CONCLUSIONS: Sirolimus-eluting stents prevent neointimal proliferation and late lumen loss irrespective of the vessel diameter. The classic inverse relationship between vessel diameter and restenosis rate was seen in the bare stent group but not in the sirolimus-eluting stent group
    corecore