11 research outputs found

    Applicability and integration of plasma sprayed hydroxyapatite coated AO cortical bone screws in equine bone

    Get PDF
    To compare insertion temperatures and torques of Hydroxyapatite (HA) coated and uncoated 5.5 mm AO cortical screws in equine third metatarsal bones (MTIII) in vitro, and to compare insertion and extraction torques of HA coated and uncoated screws after 4, 8, 12 and 16 weeks of healing in equine third metacarpal bones (MCIII) in vivo. No significant temperature differences were recorded in cadaveric bones for AO and HA coated screws. Insertion torques were significantly higher for HA coated implants compared to uncoated screws. In vivo, the AO screws lost 50% of their initial stability within 4 weeks of healing and failed to gain stability over the next 12 weeks. The HA screws maintained stability (at 4 weeks), and roughly doubled (at 8 weeks) and tripled (at 12 weeks) their insertional torques over time. HA coated screws can safely be inserted in equine cortical bone. AO cortical stainless steel screws fail to maintain stability in equine cortical bone. The addition of HA coating to the screws enables active osseointegration over 3 months of healing, as indicated by significantly higher extractional torques after 8, 12 and 16 weeks respectively. Screw failure can occur under acute load and cyclic fatigue indicating the need for improved stability in the equine patient. HA coating, leading to active osseointegration, is commonly used in human implants for this purpose. Varying results in equine models led to guarded acceptance of implant coatings amongst equine surgeons. Our results support the osseointegrative properties of HA coated screws in horses

    Untersuchung des Einwachsverhaltens von Zirkoniumdioxid-Implantaten in die Kieferknochenstruktur

    Get PDF
    ZrO2–Implantate bieten in der Oralchirurgie einige beachtenswerte Vorteile gegenüber den derzeit üblichen Titanimplantaten. Bedingung für eine gute Einbindung in den umgebenden Knochen ist dabei eine ausreichend raue Oberfläche des Implantats. Die topographische Bearbeitung birgt hierbei Probleme hinsichtlich der Festigkeit der Implantatkörper. Dennoch konnte bei Zirkoniumdioxid-Implantaten eine Oberfläche entwickelt werden, deren mittlere Rauheit (Sa) knapp die Hälfte der Rauheit der Titan-SLA-Oberfläche beträgt. Implantate mit dieser Oberfläche waren bislang anderen, in vergleichbaren Studien eingesetzten Dentalimplantaten mit anderen Oberflächen stets überlegen. In der vorliegenden tierexperimentellen Studie an 13 Miniaturschweinen wurde die Einheilung von ZrO2-Implantaten einer neuartigen Oberfläche mit der von glatten ZrO2–Prüfkörpern und Titan–SLA–Implantaten verglichen. Die Belastbarkeit des Implantat-Knochen-Verbunds wurde biomechanisch im Ausdrehversuch gemessen. Ermittelt wurde die Drehkraft, die erforderlich ist, ein Implantat nach einer Einheilzeit von 4, 8 und 12 Wochen aus dem einbettenden Gewebe zu lösen. Zusätzlich wurden 4 und 12 Wochen p.i. insgesamt 13 Prüfkörper histologisch untersucht und die direkt an die Oberfläche angrenzenden Gewebe hinsichtlich ihres mineralisierten Anteils (Knochen oder Bindegewebe) bewertet. Hierbei konnte eindeutig gezeigt werden, dass sich die Materialien Zirkoniumdioxid und Titan in ihrer grundlegenden Fähigkeit zu direkter Apposition von mineralisierter Struktur auf der Oberfläche nicht unterscheiden. Zusätzlich konnte der diagnostische Wert einer radiologischen Erfolgskontrolle p.i. durch Korrelation mit biomechanischen und histologischen Ergebnissen erbracht und deren routinemäßige Durchführung gerechtfertigt werden. Obgleich die TiSLA-Implantate zu allen Einheilzeiten deutlich größere Lösemomente erzielten als die Implantate aus ZrO2, sind die Ergebnisse für die ZrO2-Implantate positiv zu bewerten: Zum einen ist erkennbar, dass die topographische Aufbereitung der ZrO2–Implantate einen besseren und belastbareren Verbund zwischen Implantat und Knochen ergibt. Dies konnte durch größere Lösemomente der rauen im Vergleich zu den glatten ZrO2–Prüfkörpern (insbesondere nach 8 und 12 Wochen) und durchschnittlich mehr mineralisierter Substanz direkt auf der Implantatoberfläche gezeigt werden. Zum anderen war bekannt, dass bedingt durch Remodelling-Prozesse der Verbund um die SLA-Oberfläche 12 Wochen p.i. eine geringere Festigkeit aufweist, als 8 Wochen p.i. Dies spricht für eine aktive Anpassung an einwirkende Kräfte und war auch bei den neuen ZrO2-Implantaten mit rauen Oberflächen zu erkennen. Sollte es gelingen, analog der Entwicklung bei Titan-Implantaten, die Rauheit der Oberfläche auch bei ZrO2 weiter zu steigern, ist somit auch für diesen neuartigen Werkstoff eine vergleichbar gute und stabile Einheilung erwartbar. Im Hinblick auf seine überragende ästhetische Qualität könnte demnach dieser Werkstoff insbesondere im sichtbaren Frontzahnbereich Titan ersetzen

    Logik des Marktes, Marktordnung, Marktverhalten und Marktergebnisse

    No full text
    This contribution shows how the outcome of dynamic markets can be derived, without the unrealistic assumptions of a perfect market, from the current rules of a market and the possible behaviour of the actors. An analysis of the observable rules for real-lifemarkets results in transfer equations and algorithms for the calculation of the individual purchasing prices and sales quantities.With distribution functions for offer and demand, which reflect the behaviour of the actors, the collective market outcome can be calculated, such as market price and sales, their variance and time dependency as well as the distribution effects of markets. The market laws, which result by simulation and probability theory, deviate in many respects from the statements of common price- and market-theories. The new approach enables to solve current problems, such as the market design for material and immaterial goods and finance products.Market theory, market rules, market outcome, market prices, distribution effects, market laws, market simulation, market design

    Comprehensive Logistics

    No full text
    Modern logistics comprises operative logistics, analytical logistics and management of logistic networks. Central task of operative logistics is the efficient supply of required goods at the right place within the right time. Tasks of analytical logistics are designing optimal networks and systems, developing strategies for planning, scheduling and operation, and organizing efficient order and performance processes. Logistic management plans, implements and operates logistic networks and schedules orders, stocks and resources. This reference-book offers a unique survey of modern logistics. It contains proven strategies, rules and tools for the solution of a multitude of logistic problems. The analytically derived algorithms and formulas can be used for the computer-based planning of logistic systems and for the dynamic scheduling of orders and resources in supply networks. They enable significant improvements of performance, quality and costs. Their application is demonstrated by several examples from industry, trade and service providers. Apart from corrections and modifications the second edition contains a new chapter on maritime logistics. It demonstrates how the methods of this book can be used to solve complex logistic problems of practical relevance for economy, society and environment. The book is written for professionals, scientists, teachers and graduate students. An extensive index makes it a dictionary of modern logistics

    An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: two parallel transarticular headless tapered variable pitch screws versus two parallel transarticular AO cortical bone screws inserted in lag fashion

    No full text
    OBJECTIVES: To compare the mean number of cycles to failure under axial compression of equine proximal interphalangeal (PIP) joint arthrodesis constructs created by 2 parallel transarticular Acutrak Plus screws (AP-TS) or 2 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (AO-TLS). STUDY DESIGN: Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. SAMPLE POPULATION: Cadaveric adult equine forelimbs (n=5 pairs). METHODS: For each forelimb pair, 1 PIP joint was stabilized with AP-TS and 1 with AP-TLS. The 5 construct pairs were tested for cyclic fatigue under axial compression. Mean number of cycles to failure for each fixation method were compared by a paired t-test within each group with statistical significance set at P\u3c.05. RESULTS: The mean number of cycles to failure under axial compression for AO-TLS fixation and AP-TS fixation were 57,723±8488 and 35,322±4698, respectively. CONCLUSION: The AO-TLS was superior to the AP-TS in resisting cyclic fatigue under axial compression
    corecore