4 research outputs found

    Predictive factors of extubation failure in pediatric cardiac intensive care unit: A single-center retrospective study from Thailand

    Get PDF
    Introduction/objectiveExtubation failure increases morbidity and mortality in pediatric cardiac patients, a unique population including those with congenital heart disease or acquired heart disease. This study aimed to evaluate the predictive factors of extubation failure in pediatric cardiac patients and to determine the association between extubation failure and clinical outcomes.MethodsWe conducted a retrospective study in the pediatric cardiac intensive care unit (PCICU) of the Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand, from July 2016 to June 2021. Extubation failure was defined as the re-insertion of the endotracheal tube within 48 hours after extubation. Multivariable log-binomial regression with generalized estimating equations (GEE) was performed to explore the predictive factors associated with extubation failure.ResultsWe collected 318 extubation events from 246 patients. Of these, 35 (11%) events were extubation failures. In physiologic cyanosis, the extubation failure group had significantly higher SpO2 than the extubation success group (P < 0.001). The predictive factors associated with extubation failure included a history of pneumonia before extubation (RR 3.09, 95% CI 1.54–6.23, P = 0.002), stridor after extubation (RR 2.57, 95% CI 1.44–4.56, P = 0.001), history of re-intubation (RR 2.24, 95% CI 1.21–4.12, P = 0.009), and palliative surgery (RR 1.87, 95% CI 1.02–3.43, P = 0.043).ConclusionExtubation failure was identified in 11% of extubation attempts in pediatric cardiac patients. The extubation failure was associated with a longer duration of PCICU stay but not with mortality. Patients with a history of pneumonia before extubation, history of re-intubation, post-operative palliative surgery, and post-extubation stridor should receive careful consideration before extubation and close monitoring afterward. Additionally, patients with physiologic cyanosis may require balanced circulation via regulated SpO2

    Table1_Predictive factors of extubation failure in pediatric cardiac intensive care unit: A single-center retrospective study from Thailand.docx

    No full text
    Introduction/objectiveExtubation failure increases morbidity and mortality in pediatric cardiac patients, a unique population including those with congenital heart disease or acquired heart disease. This study aimed to evaluate the predictive factors of extubation failure in pediatric cardiac patients and to determine the association between extubation failure and clinical outcomes.MethodsWe conducted a retrospective study in the pediatric cardiac intensive care unit (PCICU) of the Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand, from July 2016 to June 2021. Extubation failure was defined as the re-insertion of the endotracheal tube within 48 hours after extubation. Multivariable log-binomial regression with generalized estimating equations (GEE) was performed to explore the predictive factors associated with extubation failure.ResultsWe collected 318 extubation events from 246 patients. Of these, 35 (11%) events were extubation failures. In physiologic cyanosis, the extubation failure group had significantly higher SpO2 than the extubation success group (P ConclusionExtubation failure was identified in 11% of extubation attempts in pediatric cardiac patients. The extubation failure was associated with a longer duration of PCICU stay but not with mortality. Patients with a history of pneumonia before extubation, history of re-intubation, post-operative palliative surgery, and post-extubation stridor should receive careful consideration before extubation and close monitoring afterward. Additionally, patients with physiologic cyanosis may require balanced circulation via regulated SpO2.</p

    Development of a clinical prediction tool for extubation failure in pediatric cardiac intensive care unit

    Get PDF
    Introduction/objectiveExtubation failure in pediatric patients with congenital or acquired heart diseases increases morbidity and mortality. This study aimed to develop a clinical risk score for predicting extubation failure to guide proper clinical decision-making and management.MethodsWe conducted a retrospective study. This clinical prediction score was developed using data from the Pediatric Cardiac Intensive Care Unit (PCICU) of the Faculty of Medicine, Chiang Mai University, Thailand, from July 2016 to May 2022. Extubation failure was defined as the requirement for re-intubation within 48 h after extubation. Multivariable logistic regression was used for modeling. The score was evaluated in terms of discrimination and calibration.ResultsA total of 352 extubation events from 270 patients were documented. Among these, 40 events (11.36%) were extubation failure. Factors associated with extubation failure included history of pneumonia (OR: 4.14, 95% CI: 1.83–9.37, p = 0.001), history of re-intubation (OR: 5.99, 95% CI: 2.12–16.98, p = 0.001), and high saturation in physiologic cyanosis (OR: 5.94, 95% CI: 1.87–18.84, p = 0.003). These three factors were utilized to develop the risk score. The score showed acceptable discrimination with an area under the curve (AUC) of 0.77 (95% CI: 0.69–0.86), and good calibration.ConclusionThe derived Pediatric CMU Extubation Failure Prediction Score (Ped-CMU ExFPS) could satisfactorily predict extubation failure in pediatric cardiac patients. Employing this score could promote proper personalized care. We suggest conducting further external validation studies before considering implementation in practice

    Datasheet1_Development of a clinical prediction tool for extubation failure in pediatric cardiac intensive care unit.pdf

    No full text
    Introduction/objectiveExtubation failure in pediatric patients with congenital or acquired heart diseases increases morbidity and mortality. This study aimed to develop a clinical risk score for predicting extubation failure to guide proper clinical decision-making and management.MethodsWe conducted a retrospective study. This clinical prediction score was developed using data from the Pediatric Cardiac Intensive Care Unit (PCICU) of the Faculty of Medicine, Chiang Mai University, Thailand, from July 2016 to May 2022. Extubation failure was defined as the requirement for re-intubation within 48 h after extubation. Multivariable logistic regression was used for modeling. The score was evaluated in terms of discrimination and calibration.ResultsA total of 352 extubation events from 270 patients were documented. Among these, 40 events (11.36%) were extubation failure. Factors associated with extubation failure included history of pneumonia (OR: 4.14, 95% CI: 1.83–9.37, p = 0.001), history of re-intubation (OR: 5.99, 95% CI: 2.12–16.98, p = 0.001), and high saturation in physiologic cyanosis (OR: 5.94, 95% CI: 1.87–18.84, p = 0.003). These three factors were utilized to develop the risk score. The score showed acceptable discrimination with an area under the curve (AUC) of 0.77 (95% CI: 0.69–0.86), and good calibration.ConclusionThe derived Pediatric CMU Extubation Failure Prediction Score (Ped-CMU ExFPS) could satisfactorily predict extubation failure in pediatric cardiac patients. Employing this score could promote proper personalized care. We suggest conducting further external validation studies before considering implementation in practice.</p
    corecore