5 research outputs found

    Etude expérimentale de la dynamique de croissance de défauts étendus, sous irradiation électronique à haute énergie, dans le tellurure de cadmium

    No full text
    Some results of the study of extended defects observed in CdTe after irradiation with electrons of energy considerably higher than the threshold values for displacement of cadmium and tellurium are reported in this paper. During irradiation, the displaced atoms cluster and interstitial dislocation loops appear. This effect seems to be particularly sensitive to three experimental parameters : the accelerating voltage, the dose and the specimen temperature. It is shown that the density of defects becomes greater when the accelerating voltage is raised. Due to thermal effects, the size of the loops increases and their number decreases when the specimen température is increased. When the irradiation time is long enough, another kind of defects due to vacancies can be observed.Les travaux que nous présentons ici apportent une contribution à l'étude des défauts étendus dans le CdTe obtenus aprÚs irradiation avec des électrons dont l'énergie est trÚs nettement supérieure aux seuils de déplacement du cadmium et du tellure. Lors de ces irradiations, les atomes déplacés par les électrons incidents s'agglomÚrent en positions interstitielles et forment des boucles de dislocation. Trois paramÚtres expérimentaux semblent avoir une importance primordiale : la tension accélératrice, la température et la dose. Il est mis en évidence qu'une élévation de tension favorise la formation en plus grand nombre des boucles. Les effets thermiques se manifestent par l'apparition d'amas de taille plus importante et de moindre densité lorsque la température croßt. Lorsque le temps d'exposition au faisceau électronique est suffisamment long, une nouvelle génération d'agglomérats apparaßt : ceux-ci sont constitués de lacunes

    An amperometric silicon-based biosensor for d-lactate

    No full text
    International audienceA miniaturised biosensor for d-lactate has been fabricated on silicon wafer. Microsystems technologies led to enhanced efficiency in terms of sample size and reagent consumption while equally allowing mass production. The biosensor is based on the association of an enzymatic solution including diaphorase and d-lactate dehydrogenase confined in the microstructure by a membrane and two weakly polarised gold microelectrodes. Various electrochemical pretreatments of the gold surface are performed to increase the device's sensitivity. Depending on the geometry involved, the proposed biosensor features a response time ranging from 2 to 5 min, a sensitivity of 2 or 8 ÎŒA mM−1 cm−2 and a linearity range from 5×10−3 to 1.5 mmol l−1. Its lifetime is 3 weeks with 10 assays/day
    corecore