59 research outputs found

    NMDA Receptors Are Not Required for Pattern Completion During Associative Memory Recall

    Get PDF
    Pattern completion, the ability to retrieve complete memories initiated by subsets of external cues, has been a major focus of many computation models. A previously study reports that such pattern completion requires NMDA receptors in the hippocampus. However, such a claim was derived from a non-inducible gene knockout experiment in which the NMDA receptors were absent throughout all stages of memory processes as well as animal's adult life. This raises the critical question regarding whether the previously described results were truly resulting from the requirement of the NMDA receptors in retrieval. Here, we have examined the role of the NMDA receptors in pattern completion via inducible knockout of NMDA receptors limited to the memory retrieval stage. By using two independent mouse lines, we found that inducible knockout mice, lacking NMDA receptor in either forebrain or hippocampus CA1 region at the time of memory retrieval, exhibited normal recall of associative spatial reference memory regardless of whether retrievals took place under full-cue or partial-cue conditions. Moreover, systemic antagonism of NMDA receptor during retention tests also had no effect on full-cue or partial-cue recall of spatial water maze memories. Thus, both genetic and pharmacological experiments collectively demonstrate that pattern completion during spatial associative memory recall does not require the NMDA receptor in the hippocampus or forebrain

    Metagenomic next-generation sequencing for detecting lower respiratory tract infections in sputum and bronchoalveolar lavage fluid samples from children

    Get PDF
    Lower respiratory tract infections are common in children. Bronchoalveolar lavage fluid has long been established as the best biological sample for detecting respiratory tract infections; however, it is not easily collected in children. Sputum may be used as an alternative yet its diagnostic accuracy remains controversial. Therefore, this study sought to evaluate the diagnostic accuracy of sputum for detecting lower respiratory tract infections using metagenomic next-generation sequencing. Paired sputum and bronchoalveolar lavage fluid samples were obtained from 68 patients; pathogens were detected in 67 sputum samples and 64 bronchoalveolar lavage fluid samples by metagenomic next-generation sequencing, respectively. The combined pathogen-detection rates in the sputum and bronchoalveolar lavage fluid samples were 80.90% and 66.2%, respectively. For sputum, the positive predictive values (PPVs) and negative predictive values (NPVs) for detecting bacteria were 0.72 and 0.73, respectively, with poor Kappa agreement (0.30; 95% confidence interval: 0.218–0.578, P < 0.001). However, viral detection in sputum had good sensitivity (0.87), fair specificity (0.57), and moderate Kappa agreement (0.46; 95% confidence interval: 0.231–0.693, P < 0.001). The PPVs and NPVs for viral detection in sputum were 0.82 and 0.67, respectively. The consistency between the sputum and bronchoalveolar lavage fluid was poor for bacterial detection yet moderate for viral detection. Thus, clinicians should be cautious when interpreting the results of sputum in suspected cases of lower respiratory tract infections, particularly with regards to bacterial detection in sputum. Viral detection in sputum appears to be more reliable; however, clinicians must still use comprehensive clinical judgment

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Spintronic Memristor Temperature Sensor

    No full text

    A Novel Cooperative ARQ Method for Wireless Sensor Networks

    No full text
    In wireless sensor networks, cooperative communication can combat the effects of channel fading by exploiting diversity gain achieved via cooperation communication among the relay nodes. A cooperative automatic retransmission request (ARQ) protocol based on two-relay node selection was proposed in this paper. A novel discrete time Markov chain model in order to analyze the throughput and energy efficiency was built, and system throughput and energy efficiency performance of proposed protocol and traditional ARQ protocol were studied based on such model. The numerical results reveal that the throughput and energy efficiency of the proposed protocol could perform better when compared with the traditional ARQ protocol

    Prevalence of self-reported chronic conditions and poor health among older adults with and without vision impairment in China: a nationally representative cross-sectional survey

    No full text
    Objective To examine the self-reported prevalence of 13 chronic conditions and poor health among Chinese adults aged 45 years and older with and without self-reported vision impairment.Design Cross-sectional study from the China Health and Retirement Longitudinal Study 2018, a nationally representative survey of Chinese adults aged 45 years and older involving 19 374 participants.Methods We used logistic regression to assess the association between vision impairment and 13 common chronic conditions and between vision impairment and poor health for those with any of these chronic conditions.Results Older people with self-reported vision impairment were significantly more likely to report all 13 chronic conditions (all p<0·05). After controlling for age, gender, education, residential status (rural vs urban), smoking and BMI, the highest adjusted odds were for hearing impairment (OR=4.00 (95% CI 3·60 to 4·44]) and depression (OR=2.28 (95% CI 2.06 to 2.51)). The lowest risk, though still significant, was for diabetes (OR=1·33 (95% CI 1.11 to 2.05)) and hypertension (OR=1.20 (95% CI 1.04 to 1.38)). After controlling for these potential confounding factors, among older people with chronic conditions, those with vision impairment were 2.20 to 4.04 times more likely to have poor health, compared with those without vision impairment (all p<0.001), with the exception of cancer (p=0.595).Conclusions Higher prevalence of chronic conditions is strongly associated with vision impairment among older Chinese adults and poor health is strongly associated with vision impairment among people with chronic conditions

    Effect of F/O atomic ratio on photocatalytic activity of BixOyFz

    No full text
    International audienceWe have, for the first time, prepared BiO0.9F2.35 as a new photocatalyst by a simple hydrothermal method. It is found that at different ratios of fluorine to oxygen (F/O), the BixOyFz samples have the varied internal electric field (IEF) and electrical conductivities, thus showing different photochemistry properties for the degradation of RhB. The bulk IEF and conductivity can be conveniently controlled by the F/O ratio, thus improving the photochemistry properties of layered BixOyFz. This study provides a new strategy to develop efficient photocatalysts

    A Time, Energy, and Area Efficient Domain Wall Memory-Based SPM for Embedded Systems

    No full text

    Positive and neutral updating reconsolidate aversive episodic memories via different routes

    Get PDF
    Aversive memories are long-lasting and prone to burden our emotional wellbeing and mental health. Yet, how to remedy the maladaptive effects of aversive memories remains elusive. Using memory reactivation and emotional updating manipulations, we investigated how positive and neutral emotion may update aversive memories for reconsolidation in humans. We found that positive updating after reactivation was equivalent to neutral updating in impairing true memories of a previous aversive event after a 12-hour wakeful delay, but induced more false memory. Moreover, additional 12-hour delay with overnight sleep did not further enlarge true memory differences, but attenuated the effect of reactivation and updating on false memory. Interestingly, the neutral rather than the positive updating reduced the emotional arousal of the aversive memory 24 h later. Our findings could serve as a reference for real-world therapeutic applications regarding how positive and neutral updating may reshape aversive memories, especially when taking wake- and sleep-filled reconsolidation into account.Fil: Wang, Jingyi. Beijing Normal University; ChinaFil: Chen, Boxuan. Beijing Normal University; ChinaFil: Sha, Manqi. Beijing Normal University; ChinaFil: Gu, Yiran. East China Normal University; ChinaFil: Wu, Haitao. Beijing Institute of Basic Medical Sciences; China. Chinese Institute for Brain Research; ChinaFil: Forcato, Cecilia. Instituto Tecnológico de Buenos Aires. Departamento de Investigación y Doctorado; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Qin, Shaozheng. Beijing Normal University; China. Chinese Institute for Brain Research; Chin
    • …
    corecore