248 research outputs found

    Output Voltage Response Improvement and Ripple Reduction Control for Input-parallel Output-parallel High-Power DC Supply

    Full text link
    A three-phase isolated AC-DC-DC power supply is widely used in the industrial field due to its attractive features such as high-power density, modularity for easy expansion and electrical isolation. In high-power application scenarios, it can be realized by multiple AC-DC-DC modules with Input-Parallel Output-Parallel (IPOP) mode. However, it has the problems of slow output voltage response and large ripple in some special applications, such as electrophoresis and electroplating. This paper investigates an improved Adaptive Linear Active Disturbance Rejection Control (A-LADRC) with flexible adjustment capability of the bandwidth parameter value for the high-power DC supply to improve the output voltage response speed. To reduce the DC supply ripple, a control strategy is designed for a single module to adaptively adjust the duty cycle compensation according to the output feedback value. When multiple modules are connected in parallel, a Hierarchical Delay Current Sharing Control (HDCSC) strategy for centralized controllers is proposed to make the peaks and valleys of different modules offset each other. Finally, the proposed method is verified by designing a 42V/12000A high-power DC supply, and the results demonstrate that the proposed method is effective in improving the system output voltage response speed and reducing the voltage ripple, which has significant practical engineering application value.Comment: Accepted by IEEE Transactions on Power Electronic

    Serum N‐glycans outperform CA19‐9 in diagnosis of extrahepatic cholangiocarcinoma

    Full text link
    Extensive efforts have been devoted to improve the diagnosis of extrahepatic cholangiocarcinoma (ECCA) due to its silent clinical character and lack of effective diagnostic biomarkers. Specific alterations in N‐glycosylation of glycoproteins are considered a key component in cancer progression, which can serve as a distinct molecular signature for cancer detection. This study aims to find potential serum N‐glycan markers for ECCA. In total, 255 serum samples from patients with ECCA (n = 106), benign bile tract disease (BBD, n = 60) and healthy controls (HC, n = 89) were recruited. Only 2 ΌL of serum from individual patients was used in this assay where the N‐glycome of serum glycoproteins was profiled by DNA sequencer‐assisted fluorophore‐assisted capillary electrophoresis (DSA‐FACE) technology. Multi‐parameter models were constructed by combining the N‐glycans and carbohydrate antigen 19‐9 (CA19‐9) which is currently used clinically. Quantitative analyses showed that among 13 N‐glycan structures, the bifucosylated triantennary N‐glycan (peak10, NA3F2) presented the best diagnostic performance for distinguishing ECCA from BBD and HC. Two diagnostic models (Glycotest1 and Glycotest2) performed better than single N‐glycan or CA19‐9. Additionally, two N‐glycan structures (peak9, NA3Fb; peak12, NA4Fb) were tightly related to lymph node metastasis in ECCA patients. In conclusion, sera of ECCA showed relatively specific N‐glycome profiling patterns. Serum N‐glycan markers and models are novel, valuable and noninvasive alternatives in ECCA diagnosis and progression monitoring.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/139072/1/elps6272.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/139072/2/elps6272_am.pd

    Flexible thin-film acoustic wave devices with off-axis bending characteristics for multisensing applications

    Get PDF
    Flexible surface acoustic wave (SAW) devices have recently attracted tremendous attention for their widespread applications in sensing and microfluidics. However, for these applications, the SAW devices often need to be bent into off-axis deformations between the acoustic-wave propagation direction and bending direction. Currently there are few studies on this topic, and the bending mechanisms under off-axis bending deformations have remained unexplored for multi-sensing applications. Herein, we fabricated aluminum nitride (AlN) flexible SAW devices by using high quality AlN films deposited on flexible glass substrates and systematically investigated their complex deformation behaviors. A theoretical model was firstly developed using coupling wave equations and boundary condition method to analyze the device’s characteristics with bending and off-axis deformation under elastic strains. The relationships between frequency shifts of the SAW device with bending strain and off-axis angle were obtained which showed the identical results with those from the theoretical calculations. Finally, we performed proof-of-concept demonstrations of multi-sensing applications by monitoring human wrist movements at various off-axis angles and detecting UV light intensities on a curved surface, thus paving the ways for versatile flexible electronics applications

    Mini percutaneous nephrolithotomy is a noninferior modality to standard percutaneous nephrolithotomy for the management of 20-40 mm renal calculi: A Multicenter randomized controlled trial

    Get PDF
    Background: High quality of evidence comparing mini percutaneous nephrolithotomy (mPNL) with standard percutaneous nephrolithotomy (sPNL) for the treatment of larger-sized renal stones is lacking. Objective: To compare the efficacy and safety of mPNL and sPNL for the treatment of 20–40 mm renal stones. Design, setting, and participants: A parallel, open-label, and noninferior randomized controlled trial was performed at 20 Chinese centers (2016–2019). The inclusion criteria were patients 18–70 yr old, with normal renal function, and 20–40 mm renal stones. Intervention: Percutaneous nephrolithotomy PNL was performed using either 18 F or 24 F percutaneous nephrostomy tracts. Outcome measurements and statistical analysis: The primary outcome was the one-session stone-free rate (SFR). The secondary outcomes included operating time, visual analog pain scale (VAS) score, blood loss, complications as per the Clavien-Dindo grading system, and length of hospitalization. Results and limitations: The 1980 intention-to-treat patients were randomized. The mPNL group achieved a noninferior one-session SFR to the sPNL group by the one-side noninferiority test (0.5% [difference], p < 0.001). The transfusion and embolization rates were comparable; however, the sPNL group had a higher hemoglobin drop (5.2 g/l, p < 0.001). The sPNL yielded shorter operating time (–2.2 min, p = 0.008) but a higher VAS score (0.8, p < 0.001). Patients in the sPNL group also had longer hospitalization (0.6 d, p < 0.001). There was no statistically significant difference in fever or urosepsis occurrences. The study's main limitation was that only 18F or 24F tract sizes were used. Conclusions: Mini mPNL achieves noninferior SFR outcomes to sPNL, but with reduced bleeding, less postoperative pain, and shorter hospitalization. Patient summary: We evaluated the surgical outcomes of percutaneous nephrolithotomy using two different sizes of nephrostomy tracts in a large population. We found that the smaller tract might be a sensible alternative for patients with 20–40 mm renal stones. This multicenter, parallel, open-label, and noninferior randomized controlled trial showed that mini percutaneous nephrolithotomy achieved noninferior stone-free rate with advantages of reduced blood loss, less postoperative pain, and shorter hospitalization. Mini percutaneous nephrolithotomy should be considered a sensible alternative treatment of 20–40 mm renal stones.grants from high-level development funding of Guangzhou Medical Universit

    Single Endemic Genotype of Measles Virus Continuously Circulating in China for at Least 16 Years

    Get PDF
    The incidence of measles in China from 1991 to 2008 was reviewed, and the nucleotide sequences from 1507 measles viruses (MeV) isolated during 1993 to 2008 were phylogenetically analyzed. The results showed that measles epidemics peaked approximately every 3 to 5 years with the range of measles cases detected between 56,850 and 140,048 per year. The Chinese MeV strains represented three genotypes; 1501 H1, 1 H2 and 5 A. Genotype H1 was the predominant genotype throughout China continuously circulating for at least 16 years. Genotype H1 sequences could be divided into two distinct clusters, H1a and H1b. A 4.2% average nucleotide divergence was found between the H1a and H1b clusters, and the nucleotide sequence and predicted amino acid homologies of H1a viruses were 92.3%–100% and 84.7%–100%, H1b were 97.1%–100% and 95.3%–100%, respectively. Viruses from both clusters were distributed throughout China with no apparent geographic restriction and multiple co-circulating lineages were present in many provinces. Cluster H1a and H1b viruses were co-circulating during 1993 to 2005, while no H1b viruses were detected after 2005 and the transmission of that cluster has presumably been interrupted. Analysis of the nucleotide and predicted amino acid changes in the N proteins of H1a and H1b viruses showed no evidence of selective pressure. This study investigated the genotype and cluster distribution of MeV in China over a 16-year period to establish a genetic baseline before MeV elimination in Western Pacific Region (WPR). Continuous and extensive MeV surveillance and the ability to quickly identify imported cases of measles will become more critical as measles elimination goals are achieved in China in the near future. This is the first report that a single endemic genotype of measles virus has been found to be continuously circulating in one country for at least 16 years

    Trihydrophobin 1 Phosphorylation by c-Src Regulates MAPK/ERK Signaling and Cell Migration

    Get PDF
    c-Src activates Ras-MAPK/ERK signaling pathway and regulates cell migration, while trihydrophobin 1 (TH1) inhibits MAPK/ERK activation and cell migration through interaction with A-Raf and PAK1 and inhibiting their kinase activities. Here we show that c-Src interacts with TH1 by GST-pull down assay, coimmunoprecipitation and confocal microscopy assay. The interaction leads to phosphorylation of TH1 at Tyr-6 in vivo and in vitro. Phosphorylation of TH1 decreases its association with A-Raf and PAK1. Further study reveals that Tyr-6 phosphorylation of TH1 reduces its inhibition on MAPK/ERK signaling, enhances c-Src mediated cell migration. Moreover, induced tyrosine phosphorylation of TH1 has been found by EGF and estrogen treatments. Taken together, our findings demonstrate a novel mechanism for the comprehensive regulation of Ras/Raf/MEK/ERK signaling and cell migration involving tyrosine phosphorylation of TH1 by c-Src

    Efficiency of Finding Muon Track Trigger Primitives in CMS Cathode Strip Chambers

    Get PDF
    In the CMS Experiment, muon detection in the forward direction is accomplished by cathode strip chambers~(CSC). These detectors identify muons, provide a fast muon trigger, and give a precise measurement of the muon trajectory. There are 468 six-plane CSCs in the system. The efficiency of finding muon trigger primitives (muon track segments) was studied using~36 CMS CSCs and cosmic ray muons during the Magnet Test and Cosmic Challenge~(MTCC) exercise conducted by the~CMS experiment in~2006. In contrast to earlier studies that used muon beams to illuminate a very small chamber area (< ⁣0.01< \! 0.01~m2^2), results presented in this paper were obtained by many installed CSCs operating {\em in situ} over an area of ≈ ⁣23\approx \! 23~m2^2 as a part of the~CMS experiment. The efficiency of finding 2-dimensional trigger primitives within 6-layer chambers was found to be~99.93±0.03%99.93 \pm 0.03\%. These segments, found by the CSC electronics within 800800~ns after the passing of a muon through the chambers, are the input information for the Level-1 muon trigger and, also, are a necessary condition for chambers to be read out by the Data Acquisition System
    • 

    corecore