10 research outputs found

    Inhibited Shaped Charge Launcher Testing of Spacecraft Shield Designs

    Get PDF
    This report describes a test program in which several orbital debris shield designs were impact tested using the inhibited shaped charge launcher facility at Southwest Research Institute. This facility enables researchers to study the impact of one-gram aluminum projectiles on various shielding designs at velocities above 11 km/s. A total of twenty tests were conducted on targets provided by NASA-MSFC. This report discusses in detail the shield design, the projectile parameters and the test configuration used for each test. A brief discussion of the target damage is provided, as the detailed analysis of the target response will be done by NASA-MSFC

    Inhibited Shaped Charge Launcher Testing of Spacecraft Shield Designs

    Get PDF
    This report describes a test program in which several orbital debris shield designs were impact tested using the inhibited shaped charge launcher facility at Southwest Research Institute. This facility enables researchers to study the impact of one-gram aluminum projectiles on various shielding designs at velocities above 11 km/s. A total of twenty tests were conducted on targets provided by NASA-MSFC. This report discusses in detail the shield design, the projectile parameters and the test configuration used for each test. A brief discussion of the target damage is provided, as the detailed analysis of the target response will be done by NASA-MSFC

    Secondary Impacts on Structures on the Lunar Surface

    No full text
    The Altair Lunar Lander is being designed for the planned return to the Moon by 2020. Since it is hoped that lander components will be re-used by later missions, studies are underway to examine the exposure threat to the lander sitting on the Lunar surface for extended periods. These threats involve both direct strikes of meteoroids on the vehicle as well as strikes from Lunar regolith and rock thrown by nearby meteorite strikes. Currently, the lander design is comprised of up to 10 different types of pressure vessels. These vessels included the manned habitation module, fuel, cryogenic fuel and gas storage containers, and instrument bays. These pressure vessels have various wall designs, including various aluminum alloys, honeycomb, and carbon-fiber composite materials. For some of the vessels, shielding is being considered. This program involved the test and analysis of six pressure vessel designs, one of which included a Whipple bumper shield. In addition to the pressure vessel walls, all the pressure vessels are wrapped in multi-layer insulation (MLI). Two variants were tested without the MLI to better understand the role of the MLI in the impact performance. The tests of performed were to examine the secondary impacts on these structures as they rested on the Lunar surface. If a hypervelocity meteor were to strike the surface nearby, it would throw regolith and rock debris into the structure at a much lower velocity. Also, when the manned module departs for the return to Earth, its rocket engines throw up debris that can impact the remaining lander components and cause damage. Glass spheres were used as a stimulant for the regolith material. Impact tests were performed with a gas gun to find the V50 of various sized spheres striking the pressure vessels. The impacts were then modeled and a fast-running approximate model for the V50 data was developed. This model was for performing risk analysis to assist in the vessel design and in the identification of ideal long-term mission sites. This paper reviews the impact tests and analysis and modeling examining the impact threat to various components in the lander design

    Managing the challenge of chemically reactive metabolites in drug development

    No full text
    The normal metabolism of drugs can generate metabolites that have intrinsic chemical reactivity towards cellular molecules, and therefore have the potential to alter biological function and initiate serious adverse drug reactions. Here, we present an assessment of the current approaches used for the evaluation of chemically reactive metabolites. We also describe how these approaches are being used within the pharmaceutical industry to assess and minimize the potential of drug candidates to cause toxicity. At early stages of drug discovery, iteration between medicinal chemistry and drug metabolism can eliminate perceived reactive metabolite-mediated chemical liabilities without compromising pharmacological activity or the need for extensive safety evaluation beyond standard practices. In the future, reactive metabolite evaluation may also be useful during clinical development for improving clinical risk assessment and risk management. Currently, there remains a huge gap in our understanding of the basic mechanisms that underlie chemical stress-mediated adverse reactions in humans. This Review summarizes our views on this complex topic, and includes insights into practices considered by the pharmaceutical industry

    The Mode Of Delivery And The Risk Of Vertical Transmission Of Human Immunodeficiency Virus Type 1. A Meta-Analysis Of 15 Prospective Cohort Studies

    No full text
    Background To evaluate the relation between elective cesarean section and vertical transmission of human immunodeficiency virus type 1 (HIV-1), we performed a meta-analysis using data on individual patients from 15 prospective cohort studies. Methods North American and European studies of at least 100 mother-child pairs were included in the meta-analysis. Uniform definitions of modes of delivery were used. Elective cesarean sections were defined as those performed before onset of labor and rupture of membranes. Multivariate logistic-regression analysis was used to adjust for other factors known to be associated with vertical transmission. Results The primary analysis included data on 8533 mother-child pairs. After adjustment for receipt of antiretroviral therapy, maternal stage of disease, and infant birth weight, the likelihood of vertical transmission of HIV-1 was decreased by approximately 50 percent with elective cesarean section, as compared with other modes of delivery (adjusted odds ratio, 0.43; 95 percent confidence interval, 0.33 to 0.56). The results were similar when the study population was limited to those with rupture of membranes shortly before delivery. The likelihood of transmission was reduced by approximately 87 percent with both elective cesarean section and receipt of antiretroviral therapy during the prenatal, intrapartum, and neonatal periods, as compared with other modes of delivery and the absence of therapy (adjusted odds ratio, 0.13; 95 percent confidence interval, 0.09 to 0.19), Among mother-child pairs receiving antiretroviral therapy during the prenatal, intrapartum, and neonatal periods, rates of vertical transmission were 2.0 percent among the 196 mothers who underwent elective cesarean section and 7.3 percent among the 1255 mothers with other modes of delivery. Conclusions The results of this meta-analysis suggest that elective cesarean section reduces the risk of transmission of HIV-1 from mother to child independently of the effects of treatment with zidovudine. (N Engl J Med 1999;340:977-87.) (C)1999, Massachusetts Medical Society
    corecore