643 research outputs found

    Nd-complex-doped polymer channel waveguide laser

    Get PDF
    Laser operation at 1060 nm with slope efficiency of 0.95% and 440 ÎźW output power for 2% outcoupling was demonstrated in Nd-complex-doped FDA/epoxy channel waveguides, in what to our knowledge is the first report of a rare-earth-ion-doped polymer waveguide laser. The threshold was 45 mW of absorbed pump power

    Continuous-wave Lasers in Polymer waveguides

    Get PDF
    Channel waveguides based on a polymer, 6-fluorinated-dianhydride/epoxy, which is actively doped with a rare-earth-ion-doped complex, Nd(thenoyltrifluoroacetone)3 1,10-phenanthroline, have been fabricated. Photoluminescence peaks at 880 nm, 1060 nm, and 1330 nm have been experimentally observed. By optimization of the fabrication\ud procedure of both, host material and optical structure, continuous-wave laser operation on both, the four-level and quasi-three-level transitions near 1060 nm and 880 nm, respectively, has been demonstrated in channel waveguides

    Microstructured optical fibres for gas sensing: design fabrication and post-fab processing

    No full text
    Air/silica Microstructured Optical Fibers (MOFs) offer new prospects for fiber based sensor devices. In this paper, two topics of particular significance for gas sensing using air guiding Photonic Bandgap Fibers (PBGFs) are discussed. First, we address the issue of controlling the modal properties of PBGFs and demonstrate a single mode, polarization maintaining air guiding PBGF. Secondly, we present recent improvements of a femtosecond laser machining technique for fabricating fluidic channels in PBGFs, which allowed us to achieve cells with multiple side access channels and low additional loss

    The use of twin-ring Ilizarov external fixator constructs: application and biomechanical proof-of principle with possible clinical indications

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In peri- or intra-articular fractures of the tibia or femur, the presence of short metaphyseal bone fragments may make the application of an Ilizarov external fixator (IEF) challenging. In such cases, it may be necessary to bridge the adjacent joint in order to ensure stable fixation. The twin-ring (TR) module of circular external fixation is proposed as an alternative method that avoids joint bridging, without compromising stability of fixation. The aim of this study is to present the experimental tests performed to compare the biomechanical characteristics of the single- and TR IEF modules. The clinical application of the TR module in select patients is also presented and the merits of this technique are discussed.</p> <p>Methods</p> <p>In this experimental study, the passive stiffness and stability of the single-ring (SR) and twin-ring (TR) IEF modules were tested under axial and shear loading conditions. In each module, two perpendicular wires on the upper surface and another two wires on the lower surface of the rings were used for fixation of the rings on plastic acetal cylinders simulating long bones.</p> <p>Results</p> <p>In axial loading, the main outcome measure was stiffness and the SR module proved stiffer than the TR. In shear loading, the main outcome measure was stability, the TR module proving more stable than the SR.</p> <p>Discussion</p> <p>The TR configuration, being stiffer in shear loading, may make joint bridging unnecessary when an IEF is applied. If it is still required, TR frames allow for an earlier discontinuation of bridging; either case is in favour of a successful final outcome.</p> <p>Conclusion</p> <p>The application of the TR module has led to satisfactory clinical outcomes and should be considered as an alternative in select trauma patients treated with an IEF. Biomechanically, the TR module possesses features which enhance fracture healing and at the same time obviate the need for bridging adjacent joints, thereby significantly reducing patient morbidity.</p

    A segmental radiological study of the spine and rib – cage in children with progressive Infantile Idiopathic Scoliosis

    Get PDF
    BACKGROUND: The role of rib cage in the development of progressive infantile idiopathic scoliosis (IIS) has not been studied previously. No report was found for rib growth in children with IIS. These findings caused us to undertake a segmental radiological study of the spine and rib-cage in children with progressive IIS. The aim of the present study is to present a new method for assessing the thoracic shape in scoliotics and in control subjects and to compare the findings between the two groups. MATERIALS AND METHODS: In the posteroanterior (PA) spinal radiographs of 24 patients with progressive IIS, with a mean age of 4.1 years old, the Thoracic Ratios (TRs) (segmental convex and concave TRs), the Cobb angle, the segmental vertebral rotation and vertebral tilt were measured. In 233 subjects, with a mean age of 5.1 years old, who were used as a control group, the segmental left and right TRs and the total width of the chest (left plus right TRs) were measured in PA chest radiographs. Statistical analysis included Mann-Whitney, Spearman correlation coefficient, multiple linear regression analysis and ANOVA. RESULTS: The comparison shows that the scoliotic thorax is significantly narrower than that of the controls at all spinal levels. The upper chest in IIS is funnel-shaped and the vertebral rotation at T4 early in management correlates significantly with the apical vertebral rotation at follow up. CONCLUSION: The IIS thorax is narrower than that of the controls, the upper chest is funnel-shaped and there is a predictive value of vertebral rotation at the upper limit of the thoracic curve of IIS, which reflects, impaired rib control of spinal rotation possibly due to neuromuscular factors, which contribute also to the funnel-shaped chest

    Continuous-wave lasing in a solid polymer

    Get PDF
    Channel waveguides with a Nd-complex-doped fluorinated polymer guiding core were fabricated. For the first time, continuous-wave lasing was demonstrated in a solid polymer. Lasers near 1060 nm and 878 nm were operated for 2 hours
    • …
    corecore