2 research outputs found

    Exoskeleton for ankle joint flexion/extension rehabilitation

    Get PDF
    Este trabajo presenta el modelado, dise帽o, construcci贸n, y control de un exoesqueleto para rehabilitaci贸n de la flexi贸n/extensi贸n de la articulaci贸n del tobillo. El modelo din谩mico de la flexi贸n/extensi贸n del tobillo es obtenido por medio de la formulaci贸n de Euler-Lagrange y es construido en Simulink de MATLAB usando la ecuaci贸n diferencial no-lineal derivada del an谩lisis din谩mico. Un controlador PID de realimentaci贸n del desplazamiento angular, representando el control neuromusculoesquel茅tico humano, es implementado en el modelo din谩mico para estimar el torque articular requerido durante los movimientos del tobillo. Se realizan simulaciones en el modelo para el rango de movimiento (ROM) de la flexi贸n/extensi贸n del tobillo, y los resultados son usados para seleccionar el actuador m谩s adecuado para el exoesqueleto. El exoesqueleto para rehabilitaci贸n del tobillo es dise帽ado en el software CAD SolidWorks, construido por impresi贸n 3D en 谩cido polil谩ctico (PLA), accionado por dos servomotores que entregan juntos un torque continuo m谩ximo de 22 [kg cm], y controlado por una placa Arduino que establece comunicaci贸n Bluetooth con un aplicativo m贸vil desarrollado en MIT App Inventor para la programaci贸n de los par谩metros de las terapias de rehabilitation. El resultado de este trabajo es un exoesqueleto liviano de tobillo, con una masa total de 0.85[kg] incluyendo actuadores (servomotores) y electr贸nica (microcontrolador y bater铆as), el cual puede ser usado en pr谩cticas de telerehabilitaci贸n garantizando errores de seguimiento del desplazamiento angular por debajo del 10%.This work presents the modelling, design, construction, and control of an exoskeleton for ankle joint flexion/extension rehabilitation. The dynamic model of the ankle flexion/extension is obtained through Euler-Lagrange formulation and is built in Simulink of MATLAB using the non-linear differential equation derived from the dynamic analysis. An angular displacement feedback PID controller, representing the human neuromusculoskeletal control, is implemented in the dynamic model to estimate the joint torque required during ankle movements. Simulations are carried out in the model for the ankle flexion/extension range of motion (ROM), and the results are used to select the most suitable actuators for the exoskeleton. The ankle rehabilitation exoskeleton is designed in SolidWorks CAD software, built through 3D printing in polylactic acid (PLA), powered by two on-board servomotors that deliver together a maximum continuous torque of 22 [kg cm], and controlled by an Arduino board that establishes Bluetooth communication with a mobile app developed in MIT App Inventor for programming the parameters of the rehabilitation therapies. The result of this work is a lightweight ankle exoskeleton, with a total mass of 0.85 [kg] including actuators (servomotors) and electronics (microcontroller and batteries), which can be used in telerehabilitation practices guaranteeing angular displacement tracking errors under 10%

    Ciclo de vida y descripci贸n morfol贸gica de Heilipus Lauri Boheman (COLEOPTERA: CURCULIONIDAE) en Colombia

    Get PDF
    Heilipus lauri聽Boheman is a species that affects the fruits of聽Persea americana聽Miller (Lauraceae) and is catalogued as a quarantine pest for United States market. In Colombia, it has been detected in several departments, however, its management is difficult because of the limited information about its biology and habits. With the aim of contributing to the knowledge of the biology of this species, the life cycle under laboratory conditions (21.6 卤 1.8 掳C and relative humidity of 66 卤 8%) was determined and morphological description of the developmental stages for the species was carried out. The life cycle ranging from egg to adult took lasted 76.14 卤 7.31 days in average. Of these, the egg stage lasted 12.70 卤 1.87 days, the larval stage encompassed 48.68 卤 6.41 days and the pupa 14.76 卤 1.13 days. These results represent the first record of duration of the life cycle of specimens of聽H. lauri聽associated with聽P. americana聽cv. Hass in Colombia, and might constitute the base for the development and implementation of integrated pest management.聽RESUMEN. Heilipus lauri Boheman (Coleoptera: Curculionidae) es una especie que afecta los frutos de Persea americana Miller (Lauraceae) y est谩 catalogada como plaga cuarentenaria para el mercado de Estados Unidos. En Colombia se ha detectado en varios departamentos, no obstante, su manejo se dificulta debido a la escasa informaci贸n sobre su biolog铆a y h谩bitos. Con el objetivo de contribuir al conocimiento de la biolog铆a de esta especie, se determin贸 el ciclo de vida en laboratorio (21,6 卤 1,8 掳C y humedad relativa de 66 卤 8%) y se realiz贸 la descripci贸n morfol贸gica de cada uno de sus estados de desarrollo. El ciclo de vida de huevo hasta la emergencia del adulto dur贸 76,14 卤 7,31 d铆as. De 茅stos, la etapa de huevo tuvo una duraci贸n de 12,70 卤 1,87 d铆as, el estado larval 48,68 卤 6,41 d铆as y la pupa 14,76 卤 1,13 d铆as. Estos resultados representan el primer registro de duraci贸n del ciclo de vida de espec铆menes de H. lauri asociados a P. americana cv. Hass en Colombia, y podr铆an constituir la base para el desarrollo e implementaci贸n de programas de manejo integrado de plagas.
    corecore