259 research outputs found

    Temperature Dependence of Facet Ridges in Crystal Surfaces

    Full text link
    The equilibrium crystal shape of a body-centered solid-on-solid (BCSOS) model on a honeycomb lattice is studied numerically. We focus on the facet ridge endpoints (FRE). These points are equivalent to one dimensional KPZ-type growth in the exactly soluble square lattice BCSOS model. In our more general context the transfer matrix is not stochastic at the FRE points, and a more complex structure develops. We observe ridge lines sticking into the rough phase where thesurface orientation jumps inside the rounded part of the crystal. Moreover, the rough-to-faceted edges become first-order with a jump in surface orientation, between the FRE point and Pokrovsky-Talapov (PT) type critical endpoints. The latter display anisotropic scaling with exponent z=3z=3 instead of familiar PT value z=2z=2.Comment: 12 pages, 19 figure

    Molecular basis of fibrinogen Naples associated with defective thrombin binding and thrombophilia. Homozygous substitution of B beta 68 Ala----Thr.

    Get PDF
    In an abnormal fibrinogen (fibrinogen Naples) associated with congenital thrombophilia we have identified a single base substitution (G----A) in the B beta chain gene that results in an amino acid substitution of alanine by threonine at position 68 in the B beta chain of fibrinogen. The propositus and two siblings were found to be homozygous for the mutation, whereas the parents and another sibling were found to be heterozygous. Individuals homozygous for the defect had a severe history of both arterial and venous thrombosis; heterozygous individuals had no clinical symptoms. The three homozygotes had a prolonged thrombin clotting time in plasma, whereas the heterozygotes had a normal thrombin clotting time. Fibrinopeptide A and B (FpA and FpB) release from purified fibrinogen by human alpha-thrombin was delayed in both the homozygous propositus and a heterozygous family member. Release of FpA from the normal and abnormal amino-terminal disulfide knot (NDSK) corresponded to that found with the intact fibrinogens, indicating a decreased interaction of thrombin with the NDSK part of fibrinogen Naples. Binding studies showed that fibrin from homozygous abnormal fibrinogen bound less than 10% of active site inhibited alpha-thrombin as compared with normal fibrin, while fibrin formed from heterozygous abnormal fibrinogen bound approximately 50% of alpha-thrombin. These results suggest that the mutation of B beta Ala 68----Thr affects the binding of alpha-thrombin to fibrin, and that defective binding results in a decreased release of FpA and FpB in both homozygous and heterozygous abnormal fibrinogens

    In vivo Raman spectroscopy for bladder cancer detection using a superficial Raman probe compared to a nonsuperficial Raman probe

    Get PDF
    Raman spectroscopy is promising as a noninvasive tool for cancer diagnosis. A superficial Raman probe might improve the classification of bladder cancer, because information is gained solely from the diseased tissue and irrelevant information from deeper layers is omitted. We compared Raman measurements of a superficial to a nonsuperficial probe, in bladder cancer diagnosis. Two-hundred sixteen Raman measurements and biopsies were taken in vivo from at least one suspicious and one unsuspicious bladder location in 104 patients. A Raman classification model was constructed based on histopathology, using a principal-component fed linear-discriminant-analysis and leave-one-person-out cross-validation. The diagnostic ability measured in area under the receiver operating characteristics curve was 0.95 and 0.80, the sensitivity was 90% and 85% and the specificity was 87% and 88% for the superficial and the nonsuperficial probe, respectively. We found inflammation to be a confounder and additionally we found a gradual transition from benign to low-grade to high-grade urothelial carcinoma. Raman spectroscopy provides additional information to histopathology and the diagnostic value using a superficial probe. </p

    An Efficient and Robust Algorithm for Parallel Groupwise Registration of Bone Surfaces

    Get PDF
    Abstract. In this paper a novel groupwise registration algorithm is proposed for the unbiased registration of a large number of densely sampled point clouds. The method fits an evolving mean shape to each of the example point clouds thereby minimizing the total deformation. The registration algorithm alternates between a computationally expensive, but parallelizable, deformation step of the mean shape to each example shape and a very inexpensive step updating the mean shape. The algorithm is evaluated by comparing it to a state of the art registration algorith

    Retracting and seeking movements during laparoscopic goal-oriented movements. Is the shortest path length optimal?

    Get PDF
    Aims- Minimally invasive surgery (MIS) requires a high degree of eye–hand coordination from the surgeon. To facilitate the learning process, objective assessment systems based on analysis of the instruments’ motion are being developed. To investigate the influence of performance on motion characteristics, we examined goaloriented movements in a box trainer. In general, goal-oriented movements consist of a retracting and a seeking phase, and are, however, not performed via the shortest path length. Therefore, we hypothesized that the shortest path is not an optimal concept in MIS. Methods-Participants were divided into three groups (experts, residents, and novices). Each participant performed a number of one-hand positioning tasks in a box trainer. Movements of the instrument were recorded with the TrEndo tracking system. The movement from point A to B was divided into two phases: A-M (retracting) and M-B (seeking). Normalized path lengths (given in %) of the two phases were compared. Results- Thirty eight participants contributed. For the retracting phase, we found no significant difference between experts [median (range) %: 152 (129–178)], residents [164 (126–250)], and novices [168 (136–268)]. In the seeking phase, we find a significant difference (<0.001) between experts [180 (172–247)], residents [201 (163–287)], and novices [290 (244–469)]. Moreover, within each group, a significant difference between retracting and seeking phases was observed. Conclusions- Goal-oriented movements in MIS can be split into two phases: retracting and seeking. Novices are less effective than experts and residents in the seeking phase. Therefore, the seeking phase is characteristic of performance differences. Furthermore, the retracting phase is essential, because it improves safety by avoiding intermediate tissue contact. Therefore, the shortest path length, as presently used during the assessment of basic MIS skills, may be not a proper concept for analyzing optimal movements and, therefore, needs to be revised.Biomechanical EngineeringMechanical, Maritime and Materials Engineerin

    Early detection of urothelial premalignant lesions using hexaminolevulinate fluorescence cystoscopy in high risk patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate fluorescence cystoscopy with hexaminolevulinate (HAL) in the early detection of dysplasia (DYS) and carcinoma in situ (CIS) in select high risk patients.</p> <p>Methods</p> <p>We selected 30 consecutive bladder cancer patients at high risk for progression. After endoscopic resection, all patients received (a) induction BCG schedule when needed, and (b) white light and fluorescence cystoscopy after 3 months. HAL at doses of 85 mg (GE Healthcare, Buckinghamshire, United Kingdom) dissolved in 50 ml of solvent to obtain an 8 mmol/L solution was instilled intravesically with a 12 Fr catheter into an empty bladder and left for 90 minutes. The solution was freshly prepared immediately before instillation. Cystoscopy was performed within 120 minutes of bladder emptying. Standard and fluorescence cystoscopy was performed using a double light system (Combilight PDD light source 5133, Wolf, Germany) which allowed an inspection under both white and blue light.</p> <p>Results</p> <p>The overall incidence was 43.3% dysplasia, 23.3% CIS, and 13.3% superficial transitional cell cancer. In 21 patients, HAL cystoscopy was positive with one or more fluorescent flat lesions. Of the positive cases, there were 4 CIS, 10 DYS, 2 association of CIS and DYS, 4 well-differentiated non-infiltrating bladder cancers, and 1 chronic cystitis. In 9 patients with negative HAL results, random biopsies showed 1 CIS and 1 DYS. HAL cystoscopy showed 90.1% sensitivity and 87.5% specificity with 95.2% positive predictive value and 77.8% negative predictive value.</p> <p>Conclusion</p> <p>Photodynamic diagnosis should be considered a very important tool in the diagnosis of potentially evolving flat lesions on the bladder mucosa such as DYS and CIS. Moreover, detection of dysplasic lesions that are considered precursors of CIS may play an important role in preventing disease progression. In our opinion, HAL cystoscopy should be recommended in the early follow-up of high risk patients.</p

    The Impact of Different Types of Assistive Devices on Gait Measures and Safety in Huntington's Disease

    Get PDF
    BACKGROUND: Gait and balance impairments lead to frequent falls and injuries in individuals with Huntington's disease (HD). Assistive devices (ADs) such as canes and walkers are often prescribed to prevent falls, but their efficacy is unknown. We systematically examined the effects of different types of ADs on quantitative gait measures during walking in a straight path and around obstacles. METHODS: Spatial and temporal gait parameters were measured in 21 subjects with HD as they walked across a GAITRite walkway under 7 conditions (i.e., using no AD and 6 commonly prescribed ADs: a cane, a weighted cane, a standard walker, and a 2, 3 or 4 wheeled walker). Subjects also were timed and observed for number of stumbles and falls while walking around two obstacles in a figure-of-eight pattern. RESULTS: Gait measure variability (i.e., coefficient of variation), an indicator of fall risk, was consistently better when using the 4WW compared to other ADs. Subjects also walked the fastest and had the fewest number of stumbles and falls when using the 4WW in the figure-of-eight course. Subjects walked significantly slower using ADs compared to no AD both across the GAITRite and in the figure-of-eight. Measures reflecting gait stability and safety improved with the 4WW but were made worse by some other ADs
    corecore