21 research outputs found

    Outcome and risk factors for recurrence of early onset fracture-related infections treated with debridement, antibiotics and implant retention:Results of a large retrospective multicentre cohort study

    Get PDF
    Introduction: Early Fracture-Related Infections (FRIs) are a common entity in hospitals treating trauma patients and are often treated with a Debridement, Antibiotics and Implant Retention (DAIR) procedure. Aims of this study were to 1) evaluate the recurrence rate after DAIR procedures for early onset FRI, 2) establish the number of surgical procedures to gain control of the initial infection and 3) identify independent predictors for recurrence in this cohort. Methods: A retrospective multicentre cohort study was conducted in two level 1 trauma centres. Consecutive patients who underwent a DAIR procedure between January 1st 2015 and July 1st 2020 for confirmed FRI with an onset of <6 weeks after the latest osseous operation were included. Recorded data included patient demographics, treatment characteristics and follow-up. Univariate and multivariate logistic regression analyses were performed to assess predictors for recurrent FRI. Results: A total of 141 patients with early FRI were included in this study with a median age of 54.0 years (interquartile range (IQR) 34.5–64.0). The recurrence rate of FRI was 13% (n = 19) at one year follow-up and 18% (n = 25) at 23.1 months (IQR 15.3–36.4) follow-up. Infection control was achieved in 94% (n = 127/135) of cases. In total, 73 patients (52%) underwent at least two surgical procedures to treat the ongoing initial episode of FRI, of whom 54 patients (74%) required two to three procedures and 17 patients (23%) four to five procedures. Predictors for recurrent FRI were use of an intramedullary nail during index operation (odds ratio (OR) 4.0 (95% confidence interval (CI) 1.1–13.8)), need for additional surgical procedures to treat ongoing infection during the treatment period following the first presentation of early FRI (OR 1.9 (95% CI 1.1–3.5)) and a decreased Injury Severity Score (ISS) (inverted OR 1.1 (95% CI 1.0–1.1)). Conclusion: The recurrence rate after treatment of early onset FRI in patients treated with a DAIR procedure was 18% at 23.1 months follow-up. At least two surgical procedures to gain control of the initial infection were needed in 52% of patients. Independent predictors for recurrent FRI were the use of an intramedullary nail during index operation, need for additional surgical procedures and a decreased ISS

    Influence of Conversion and Anastomotic Leakage on Survival in Rectal Cancer Surgery; Retrospective Cross-sectional Study

    Get PDF

    Diagnostic accuracy of serum inflammatory markers in late fracture-related infection

    Get PDF
    Aims To assess the diagnostic value of C-reactive protein (CRP), leucocyte count (LC), and erythrocyte sedimentation rate (ESR) in late fracture-related infection (FRI). Materials and Methods PubMed, Embase, and Cochrane databases were searched focusing on the diagnostic value of CRP, LC, and ESR in late FRI. Sensitivity and specificity combinations were extracted for each marker. Average estimates were obtained using bivariate mixed effects models. Results A total of 8284 articles were identified but only six were suitable for inclusion. Sensitivity of CRP ranged from 60.0% to 100.0% and specificity from 34.3% to 85.7% in all publications considered. Five articles were pooled for meta-analysis, showing a sensitivity and specificity of 77.0% and 67.9%, respectively. For LC, this was 22.9% to 72.6%, and 73.5% to 85.7%, respectively, in five articles. Four articles were pooled for meta-analysis, resulting in a 51.7% sensitivity and 67.1% specificity. For ESR, sensitivity and specificity ranged from 37.1% to 100.0% and 59.0% to 85.0%, respectively, in five articles. Three articles were pooled in meta-analysis, showing a 45.1% sensitivity and 79.3% specificity. Four articles analyzed the value of combined inflammatory markers, reporting an increased diagnostic accuracy. These results could not be pooled due to heterogeneity. Conclusion The serum inflammatory markers CRP, LC, and ESR are insufficiently accurate to diagnose late FRI, but they may be used as a suggestive sign in its diagnosis

    Diagnostic accuracy of serum inflammatory markers in late fracture-related infection

    Get PDF
    Aims To assess the diagnostic value of C-reactive protein (CRP), leucocyte count (LC), and erythrocyte sedimentation rate (ESR) in late fracture-related infection (FRI). Materials and Methods PubMed, Embase, and Cochrane databases were searched focusing on the diagnostic value of CRP, LC, and ESR in late FRI. Sensitivity and specificity combinations were extracted for each marker. Average estimates were obtained using bivariate mixed effects models. Results A total of 8284 articles were identified but only six were suitable for inclusion. Sensitivity of CRP ranged from 60.0% to 100.0% and specificity from 34.3% to 85.7% in all publications considered. Five articles were pooled for meta-analysis, showing a sensitivity and specificity of 77.0% and 67.9%, respectively. For LC, this was 22.9% to 72.6%, and 73.5% to 85.7%, respectively, in five articles. Four articles were pooled for meta-analysis, resulting in a 51.7% sensitivity and 67.1% specificity. For ESR, sensitivity and specificity ranged from 37.1% to 100.0% and 59.0% to 85.0%, respectively, in five articles. Three articles were pooled in meta-analysis, showing a 45.1% sensitivity and 79.3% specificity. Four articles analyzed the value of combined inflammatory markers, reporting an increased diagnostic accuracy. These results could not be pooled due to heterogeneity. Conclusion The serum inflammatory markers CRP, LC, and ESR are insufficiently accurate to diagnose late FRI, but they may be used as a suggestive sign in its diagnosis

    High diagnostic accuracy of white blood cell scintigraphy for fracture related infections : Results of a large retrospective single-center study

    No full text
    Introduction: White blood cell (WBC) scintigraphy for diagnosing fracture-related infections (FRIs) has only been investigated in small patient series. Aims of this study were (1) to establish the accuracy of WBC scintigraphy for diagnosing FRIs, and (2) to investigate whether the duration of the time interval between surgery and WBC scintigraphy influences its accuracy. Patients and methods: 192 consecutive WBC scintigraphies with 99mTc-HMPAO-labelled autologous leucocytes performed for suspected peripheral FRI were included. The golden standard was based on the outcome of microbiological investigation in case of surgery, or − when these were not available – on clinical follow-up of at least six months. The discriminative ability of the imaging modalities was quantified by several measures of diagnostic accuracy. A multivariable logistic regression analysis was performed to identify predictive variables of a false-positive or false-negative WBC scintigraphy test result. Results: WBC scintigraphy had a sensitivity of 0.79, a specificity of 0.97, a positive predicting value of 0.91, a negative predicting value of 0.93 and a diagnostic accuracy of 0.92 for detecting an FRI in the peripheral skeleton. The duration of the interval between surgery and the WBC scintigraphy did not influence its diagnostic accuracy; neither did concomitant use of antibiotics or NSAIDs. There were 11 patients with a false-negative (FN) WBC scintigraphy, the majority of these patients (n = 9, 82%) suffered from an infected nonunion. Four patients had a false-positive (FP) WBC scintigraphy. Conclusions: WBC scintigraphy showed a high diagnostic accuracy (0.92) for detecting FRIs in the peripheral skeleton. Duration of the time interval between surgery for the initial injury and the WBC did not influence the results which indicate that WBC scintigraphy is accurate shortly after surgery
    corecore