43 research outputs found

    Demonstration of Weak-Link Physics in the Dynamical Response of Transition-Edge Sensors

    Full text link
    We theoretically predict and experimentally observe the onset of weak-link physics in the dynamical response of transition edge sensors (TES). We develop a theoretical framework based on a Fokker-Planck description that unifies the TES electrical response, stemming from Josephson phenomena, with electrothermal effects due to coupling to a thermal bath. Our measurements of a varying dynamic resistance are in excellent agreement with our theory, thereby ruling out predictions based on a two-fluid model and establishing weak-link phenomena as the main mechanism underlying the operation of TES. Furthermore, our description enables the calculation of power spectral densities, paving the way for a more thorough investigation of the unexplained "excess noise" in long diffusive junctions and TES reported in recent experiments

    Complete model of a spherical gravitational wave detector with capacitive transducers. Calibration and sensitivity optimization

    Get PDF
    We report the results of a detailed numerical analysis of a real resonant spherical gravitational wave antenna operating with six resonant two-mode capacitive transducers read out by superconducting quantum interference devices (SQUID) amplifiers. We derive a set of equations to describe the electro-mechanical dynamics of the detector. The model takes into account the effect of all the noise sources present in each transducer chain: the thermal noise associated with the mechanical resonators, the thermal noise from the superconducting impedance matching transformer, the back-action noise and the additive current noise of the SQUID amplifier. Asymmetries in the detector signal-to-noise ratio and bandwidth, coming from considering the transducers not as point-like objects but as sensor with physically defined geometry and dimension, are also investigated. We calculate the sensitivity for an ultracryogenic, 30 ton, 2 meter in diameter, spherical detector with optimal and non-optimal impedance matching of the electrical read-out scheme to the mechanical modes. The results of the analysis is useful not only to optimize existing smaller mass spherical detector like MiniGrail, in Leiden, but also as a technological guideline for future massive detectors. Furthermore we calculate the antenna patterns when the sphere operates with one, three and six resonators. The sky coverage for two detectors based in The Netherlands and Brasil and operating in coincidence is also estimated. Finally, we describe and numerically verify a calibration and filtering procedure useful for diagnostic and detection purposes in analogy with existing resonant bar detectors.Comment: 23 pages, 20 figures, codes of the simulations are available on request by contacting the autho

    Development of frequency domain multiplexing for the X-ray Integral Field Unit (X-IFU) on the Athena

    Full text link
    We are developing the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU instrument consists of an array of ∼\sim3840 TESs with a high quantum efficiency (>>90 \%) and spectral resolution ΔE\Delta E=2.5 eV @@ 7 keV (E/ΔE∼E/\Delta E\sim2800). FDM is currently the baseline readout system for the X-IFU instrument. Using high quality factor LC filters and room temperature electronics developed at SRON and low-noise two stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We have achieved X-ray energy resolutions ∼\sim2.5 eV at AC bias frequency at 1.7 MHz in the single pixel read-out. We have also demonstrated for the first time an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES array (GSFC-A1). In this paper we report on the single pixel performance of these microcalorimeters under MHz AC bias, and further results of the performance of these pixels under FDM.Comment: 8 pages, 4 figures, Proceedings of the SPIE Astronomical Instrumentation "Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray
    corecore