135 research outputs found

    Nellix endovascular aortic sealing endoprosthesis late explantation for concomitant type I endoleak and stent frames proximal caudal migration

    Get PDF
    Endovascular aneurysm sealing (EVAS) using the Nellixâ„¢ System was introduced in clinical practice with the aim of reducing the incidence of complications such as migration, endoleaks, and reinterventions after conventional endovascular aneurysm repair (EVAR). Although, initial efficacy data on this device have been encouraging, EVAS has also demonstrated to undergo adverse events. Herein, we report a case of Nellix graft explant due to endobags shrinkage after air bubble reabsorption leading to proximal type I A endoleak and stent migration. The focus of this article is on the importance of a more assiduous surveillance of this new device, in particular in those cases with air into the endobags immediately after the procedure; this surveillance should be aimed to timely identify complications which can otherwise lead to consequences that require open conversion

    Single-center experience in the treatment of visceral artery aneurysms

    Get PDF
    Background: Visceral artery aneurysms (VAAs), although rare, represent a life-threatening disease with high mortality rates. With the more frequent use of diagnostic tests, there has been an incidental detection of these lesions which are mostly asymptomatic. It follows that surgeons are increasingly called to decide on the most appropriate management of VAAs between an open surgical or endovascular approach and among the different endovascular options currently available. The aim of this retrospective study was to evaluate the results of open surgery and interventional endovascular strategies of visceral artery aneurysms with respect to technical success, therapy-associated complications, and postinterventional follow-up in the elective and emergency situation. Methods: From January 1992 to January 2017, 125 open surgical or endovascular interventions for VAA were performed at our institution. Once the VAA was diagnosed and the indication for treatment was assessed, the preoperative diagnostic work-up consisted of contrast computed tomography (CT) or magnetic resonance imaging (MRI) and, in some patients, digital subtraction angiography. Follow-up included clinical and duplex ultrasound scan (DUS) and contrast-enhanced ultrasound to assess the treated vessel patency and organ perfusion after 1, 6, and 12 months, and yearly thereafter. CT or MRI controls were also performed at 1 year of follow-up and only when DUS was not diagnostic or showed a complication thereafter. After the first 5 years of follow-up, the status of the patient was obtained by a structured telephone survey. Results: The treatment option was endovascular in 56 of 125 cases (44.8%). Technical success was 98.3%. In one case, the procedure was interrupted for the extensive dissection of the afferent vessel. Twenty-six patients were treated by coil embolization while 29 with covered stenting. The endovascular approach was in emergency in two cases (3.6%). In the endovascular group, mortality was nil. Complications occurred in 5 cases (8.9%): 1 subacute intestinal ischemia caused by superior mesenteric artery dissection, 2 aneurysm reperfusion, 1 stent thrombosis, and 1 massive splenic hematoma. In 69 (55.2%) cases, surgical treatment was preferred, with 24 VAA resections and 45 arterial reconstructions. In 20 cases (29%), open surgery was performed in emergency conditions. In the surgical group, 8 emergency patients (40%) died intraoperatively. The mortality after elective surgical interventions was nil. Complications after surgery were 4 graft late thrombosis (5.8%): asymptomatic in three cases and requiring splenectomy in one. Conclusions: There is no overall consensus regarding the indications for treatment of VAA. Currently in emergent setting, the endovascular approach should be considered as the first choice because of its reduced invasiveness, faster way to access and bleeding control; this accounts for the lower morality of the interventional therapy than open surgery. Endovascular approach is effective for elective repair of VAAs, but procedure-related complications may occur in a not negligible number of patients. Given comparable mortality rates and low procedure-related complication rate, surgical approach still has space in the elective management of VAAs, especially for aneurysms unsuitable or challenging for the endovascular option in patients with low surgical risk. The size, location, and morphology of VAAs, systemic or local comorbidities, and specific anatomical situations such as previous abdominal surgery should dictate treatment choice

    A post-market, prospective, multi-center, single-arm clinical investigation of Phasixâ„¢ mesh for VHWG grade 3 midline incisional hernia repair

    Get PDF
    BACKGROUND: Incisional heia is a frequent complication of midline laparotomy. The use of mesh in hernia repair has been reported to lead to fewer recurrences compared to primary repair. However, in Ventral Hernia Working Group (VHWG) Grade 3 hernia patients, whose hernia is potentially contaminated, synthetic mesh is prone to infection. There is a strong preference for resorbable biological mesh in contaminated fields, since it is more able to resist infection, and because it is fully resorbed, the chance of a foreign body reaction is reduced. However, when not crosslinked, biological resorbable mesh products tend to degrade too quickly to facilitate native cellular ingrowth. Phasix™ Mesh is a biosynthetic mesh with both the biocompatibility and resorbability of a biological mesh and the mechanical strength of a synthetic mesh. This multi-center single-arm study aims to collect data on safety and performance of Phasix™ Mesh in Grade 3 hernia patients. METHODS: A total of 85 VHWG Grade 3 hernia patients will be treated with Phasix™ Mesh in 15 sites across Europe. The primary outcome is Surgical Site Occurrence (SSO) including hematoma, seroma, infection, dehiscence and fistula formation (requiring intervention) through 3 months. Secondary outcomes include recurrence, infection and quality of life related outcomes after 24 months. Follow-up visits will be at drain removal (if drains were not placed, then on discharge or staple removal instead) and in the 1st, 3rd, 6th, 12th, 18th and 24th month after surgery. CONCLUSION: Based on evidence from this clinical study Depending on the results this clinical study will yield, Phasix™ Mesh may become a preferred treatment option in VHWG Grade 3 patients. TRIAL REGISTRATION: The trial was registered on March 25, 2016 on clinicaltrials.gov: NCT02720042

    O trabalho profissional burocrático: modelo de análise da profissionalização do trabalho em serviço social no setor não lucrativo em Portugal

    Full text link

    Gli esami ad ultrasuoni per il chirurgo vascolare

    No full text
    not availabl

    Clinical Evaluation.

    No full text
    • …
    corecore