13 research outputs found

    Comparison of the Influence of "Solvent/Non-Solvent” Treatment for the Attachment of Signal Molecules on the Structure of Electrospun PCL and PLLA Biodegradable Scaffolds

    Get PDF
    Electrospun biodegradable scaffolds (matrixes) made of poly([epsilon]-caprolactone) (PCL) and poly(L-lactic acid) (PLLA) are three-dimensional fibrous structures that are commonly used in regenerative medicine and drug delivery systems. Modification of such structures allows manipulating with biological and immune response. Previously, our team suggested a number of surface modification strategies for thin films made of PLLA. One of the proposed strategies are based on treatment of the material with “solvent/non-solvent” mixture that allows absorbing biologically active molecules or linkers on the surface of the sample. The aim of this work was to compare the influence of “solvent/non-solvent” treatment on the structure and crystallinity of the elecrospun biodegradable PCL and PLLA scaffolds. For that purpose, original PCL and PLLA scaffolds were treated with mixture of toluene and ethanol in different proportions. Morphology of the obtained samples was studied using scanning electron microscopy. It was shown that “solvent/non-solvent” treatment doesn’t lead to changes in scaffolds morphology such as gluing or cutting of the matrix fibers. By means of X-ray diffraction analysis it was shown that treatment of the samples with selected mixtures doesn’t change material crystallinity. Thus, it was demonstrated that proposed composition of the “solvent/nonsolvent” mixture can be used for the modification of electrospun PCL and PLLA scaffolds

    Controlled drug release from electrospun PCL non-woven scaffolds via multi-layering and e-beam treatment

    Get PDF
    Currently, electrospun synthetic bioresorbable polymer scaffolds are applied in regenerative medicine and tissue engineering as targeted drug delivery devices because of their mechanical and physico-chemical properties. To control the rate of polymer degradation and drug release from polymer scaffolds, surface modification techniques are widely used. In this study, paracetamol-loaded poly (ε-caprolactone) electrospun fibrous scaffolds were treated by the pulsed electron beam irradiation. Pure control PCL scaffold, as well as scaffolds with four paracetamol concentrations (2 wt./wt. %, 8 wt./wt. %, 16 wt./wt. %, and 32 wt./wt.%) were modified. The mechanical and chemical properties and morphology of modified materials were examined. The sustained release of the model drug over a period of one hour for both non-treated and treated samples was demonstrated. It was shown that treatment leads to an increase in drug release rate and does not change surface morphology of scaffolds and fibers diameter distribution

    Antibacterial ferroelectric hybrid membranes fabricated via electrospinning for wound healing

    Get PDF
    n the present study, wound healing ferroelectric membranes doped with zinc oxide nanoparticles were fabricated from vinylidene fluoride-tetrafluoroethylene copolymer and polyvinylpyrrolidone using the electrospinning technique. Five different ratios of vinylidene fluoride-tetrafluoroethylene to polyvinylpyrrolidone were used to control the properties of the membranes at a constant zinc oxide nanoparticle content. It was found that an increase of polyvinylpyrrolidone content leads to a decrease of the spinning solution conductivity and viscosity, causing a decrease of the average fiber diameter and reducing their strength and elongation. By means of X-ray diffraction and infrared spectroscopy, it was revealed that increased polyvinylpyrrolidone content leads to difficulty in crystallization of the vinylidene fluoride-tetrafluoroethylene copolymer in the ferroelectric β-phase in membranes. Changing the ratio of vinylidene fluoride-tetrafluoroethylene copolymer and polyvinylpyrrolidone with a constant content of zinc oxide nanoparticles is an effective approach to control the antibacterial properties of membranes towards Staphylococcus aureus. After carrying out in vivo experiments, we found that ferroelectric hybrid membranes, containing from five to ten mass percent of PVP, have the greatest wound-healing effect for the healing of purulent wound

    DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility

    Get PDF
    In this paper, the results on the fabrication of ferroelectric membranes as vascular patches with modified surfaces are presented. For the modification of a membrane surface contacting blood, DLC coating was deposited using the pulsed vacuum arc deposition technique. The physico-chemical properties and cytotoxicity of the membranes modified under various conditions were studied. It was found that DLC coatings do not affect membrane microstructure, preserving its crystal structure as well as its high strength and elongation. It was revealed that an increase in the capacitor storage voltage results in the rise in sp2- and sp-hybridized carbon concentration, which makes it possible to control the chemical structure and surface energy of the modified surface. The experiments with 3T3L1 fibroblasts showed no toxic effects of the materials extracts

    Pulsed Vacuum Arc Deposition of Nitrogen-Doped Diamond-like Coatings for Long-Term Hydrophilicity of Electrospun Poly(ε-caprolactone) Scaffolds

    Get PDF
    The surface hydrophobicity of poly(ε-caprolactone) electrospun scaffolds prevents their interactions with cells and tissue integration. Although plasma treatment of scaffolds enhances their hydrophilicity, this effect is temporary, and the hydrophobicity of the scaffolds is restored in about 30 days. In this communication, we report a method for hydrophilization of poly(ε-caprolactone) electrospun scaffolds for more than 6 months. To that end, diamond-like coating was deposited on the surface of the scaffolds in a nitrogen atmosphere using pulsed vacuum arc deposition with sputtering of graphite target. This approach allows for a single-side hydrophilization of the scaffold (water contact angle of 22 ± 3° vs. 126 ± 2° for pristine PCL scaffold) and preserves its structure. With increased nitrogen pressure in the chamber, sp3-hybridized carbon content decreased twice (sp2/sp3 ratio decreased from 1.06 to 0.52), which demonstrates the possibility of tailoring the content of carbon in sp2 and sp3 hybridization state. Nitrogen content in the deposited coatings was found at 16.1 ± 0.9 at.%. In vitro tests with fibroblast cell culture did not reveal any cytotoxic compounds in sample extracts

    Comparison of the Influence of “Solvent/Non-Solvent” Treatment for the Attachment of Signal Molecules on the Structure of Electrospun PCL and PLLA Biodegradable Scaffolds

    No full text
    Electrospun biodegradable scaffolds (matrixes) made of poly(ε-caprolactone) (PCL) and poly(L-lactic acid) (PLLA) are three-dimensional fibrous structures that are commonly used in regenerative medicine and drug delivery systems. Modification of such structures allows manipulating with biological and immune response. Previously, our team suggested a number of surface modification strategies for thin films made of PLLA. One of the proposed strategies are based on treatment of the material with “solvent/non-solvent” mixture that allows absorbing biologically active molecules or linkers on the surface of the sample. The aim of this work was to compare the influence of “solvent/non-solvent” treatment on the structure and crystallinity of the elecrospun biodegradable PCL and PLLA scaffolds. For that purpose, original PCL and PLLA scaffolds were treated with mixture of toluene and ethanol in different proportions. Morphology of the obtained samples was studied using scanning electron microscopy. It was shown that “solvent/non-solvent” treatment doesn’t lead to changes in scaffolds morphology such as gluing or cutting of the matrix fibers. By means of X-ray diffraction analysis it was shown that treatment of the samples with selected mixtures doesn’t change material crystallinity. Thus, it was demonstrated that proposed composition of the “solvent/nonsolvent” mixture can be used for the modification of electrospun PCL and PLLA scaffolds

    DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility

    No full text
    In this paper, the results on the fabrication of ferroelectric membranes as vascular patches with modified surfaces are presented. For the modification of a membrane surface contacting blood, DLC coating was deposited using the pulsed vacuum arc deposition technique. The physico-chemical properties and cytotoxicity of the membranes modified under various conditions were studied. It was found that DLC coatings do not affect membrane microstructure, preserving its crystal structure as well as its high strength and elongation. It was revealed that an increase in the capacitor storage voltage results in the rise in sp2- and sp-hybridized carbon concentration, which makes it possible to control the chemical structure and surface energy of the modified surface. The experiments with 3T3L1 fibroblasts showed no toxic effects of the materials extracts

    Pulsed Vacuum Arc Deposition of Nitrogen-Doped Diamond-like Coatings for Long-Term Hydrophilicity of Electrospun Poly(ε-caprolactone) Scaffolds

    No full text
    The surface hydrophobicity of poly(ε-caprolactone) electrospun scaffolds prevents their interactions with cells and tissue integration. Although plasma treatment of scaffolds enhances their hydrophilicity, this effect is temporary, and the hydrophobicity of the scaffolds is restored in about 30 days. In this communication, we report a method for hydrophilization of poly(ε-caprolactone) electrospun scaffolds for more than 6 months. To that end, diamond-like coating was deposited on the surface of the scaffolds in a nitrogen atmosphere using pulsed vacuum arc deposition with sputtering of graphite target. This approach allows for a single-side hydrophilization of the scaffold (water contact angle of 22 ± 3° vs. 126 ± 2° for pristine PCL scaffold) and preserves its structure. With increased nitrogen pressure in the chamber, sp3-hybridized carbon content decreased twice (sp2/sp3 ratio decreased from 1.06 to 0.52), which demonstrates the possibility of tailoring the content of carbon in sp2 and sp3 hybridization state. Nitrogen content in the deposited coatings was found at 16.1 ± 0.9 at.%. In vitro tests with fibroblast cell culture did not reveal any cytotoxic compounds in sample extracts

    A new approach for the immobilization of poly(acrylic) acid as a chemically reactive cross-linker on the surface of poly(lactic) acid-based biomaterials

    No full text
    A new approach for the immobilization of poly(acrylic) acid (PAA) as a chemically reactive cross-linker on the surface of poly(lactic) acid-based (PLA) biomaterials is described. The proposed technique includes non-covalent attachment of a PAA layer to the surface of PLA-based biomaterial via biomaterial surface treatment with solvent/non-solvent mixture followed by the entrapment of PAA from its solution. Surface morphology and wettability of the obtained PLA-PAA composite materials were investigated by AFM and the sitting drop method respectively. The amount of the carboxyl groups on the composites surface was determined by using the fluorescent compounds (2-(5-aminobenzo[d]oxazol-2-yl)phenol (ABO) and its acyl derivative N-(2-(2-hydroxyphenyl)benzo[d]oxazol-5-yl)acetamide (AcABO)). It was shown that it is possible to obtain PLA-PAA composites with various surface relief and tunable wettability (57°, 62° and 66°). The capacity of the created PAA layer could be varied from 1.5 nmol/cm2 to 0.1 μmol/cm2 depending on the modification conditions. Additionally, using bovine serum albumin (BSA) it was demonstrated that such composites could be modified with proteins with high binding density (around 0.18 nmol/cm2). Obtained fluoro-labeled PLA-PAA materials, as well as PLA-PAA composites themselves, are valuable since they can be used for biodegradable polymer implants tracking in living systems and as drug delivery systems
    corecore