211 research outputs found

    The <i>in vivo</i> effect of a porous titanium alloy flange with hydroxyapatite, silver and fibronectin coatings on soft-tissue integration of intraosseous transcutaneous amputation prostheses

    Get PDF
    AIMS: The Intraosseous Transcutaneous Amputation Prosthesis (ITAP) may improve quality of life for amputees by avoiding soft-tissue complications associated with socket prostheses and by improving sensory feedback and function. It relies on the formation of a seal between the soft tissues and the implant and currently has a flange with drilled holes to promote dermal attachment. Despite this, infection remains a significant risk. This study explored alternative strategies to enhance soft-tissue integration. MATERIALS AND METHODS: The effect of ITAP pins with a fully porous titanium alloy flange with interconnected pores on soft-tissue integration was investigated. The flanges were coated with fibronectin-functionalised hydroxyapatite and silver coatings, which have been shown to have an antibacterial effect, while also promoting viable fibroblast growth in vitro. The ITAP pins were implanted along the length of ovine tibias, and histological assessment was undertaken four weeks post-operatively. RESULTS: The porous titanium alloy flange reduced epithelial downgrowth and increased soft-tissue integration compared with the current drilled flange. The addition of coatings did not enhance these effects. CONCLUSION: These results indicate that a fully porous titanium alloy flange has the potential to increase the soft-tissue seal around ITAP and reduce susceptibility to infection compared with the current design

    Demineralized bone matrix to augment tendon-bone healing:a systematic review

    Get PDF
    BACKGROUND: Following injury to the rotator cuff and anterior cruciate ligament, a direct enthesis is not regenerated, and healing occurs with biomechanically inferior fibrous tissue. Demineralized bone matrix (DBM) is a collagen scaffold that contains growth factors and is a promising biological material for tendon and ligament repair because it can regenerate a direct fibrocartilaginous insertion via endochondral ossification. Purpose: To provide a comprehensive review of the literature investigating the use of DBM to augment tendon-bone healing in tendon repair and anterior cruciate ligament reconstruction (ACLR). Study Design: Systematic review. METHODS: Electronic databases (MEDLINE and EMBASE) were searched for preclinical and clinical studies that evaluated the use of DBM in tendon repair and ACLR. Search terms included the following: ("demineralized bone matrix" OR "demineralized cortical bone") AND ("tissue scaffold" OR "tissue engineering" OR "ligament" OR "tendon" OR "anterior cruciate ligament" OR "rotator cuff"). Peer-reviewed articles written in English were included, and no date restriction was applied (searches performed February 10, 2017). Methodological quality was assessed with peer-reviewed scoring criteria. RESULTS: The search strategy identified 339 articles. After removal of duplicates and screening according to inclusion criteria, 8 studies were included for full review (tendon repair, n = 4; ACLR, n = 4). No human clinical studies were identified. All 8 studies were preclinical animal studies with good methodological quality. Five studies compared DBM augmentation with non-DBM controls, of which 4 (80%) reported positive findings in terms of histological and biomechanical outcomes. CONCLUSION: Preclinical evidence indicates that DBM can improve tendon-bone healing, although clinical studies are lacking. A range of animal models of tendon repair and ACLR showed that DBM can re-create a direct fibrocartilaginous enthesis, although the animal models are not without limitations. Before clinical trials are justified, research is required that determines the best source of DBM (allogenic vs xenogenic) and the best form of DBM (demineralized cortical bone vs DBM paste) to be used in them

    The effect of temperature on the viability of human mesenchymal stem cells

    Get PDF
    Introduction Impaction allograft with cement is a common technique used in revision hip surgeries for the last 20 years. However, its clinical results are inconsistent. Recent studies have shown that mesenchymal stem cells (MSCs) seeded onto allograft can enhance bone formation. This in vitro study investigates whether the increase in temperature related to the polymerisation of bone cement will affect the viability of human MSCs. Methods The viability of human MSCs was measured after incubating them at temperatures of 38°C, 48°C and 58°C; durations 45 seconds, 80 seconds and 150 seconds. A control group was kept at 37°C and 5% carbon dioxide for the duration of the investigation (7 days). During the course of the study the human MSCs were analysed for cell metabolic activity using the alamarBlue™ assay, cell viability using both Trypan Blue dye exclusion and calcein staining under fluorescent microscopy, and necrosis and apoptosis using Annexin V and propidium iodide for flow cytometric analysis. A one-way analysis of variance with a priori Dunnett’s test was used to indicate the differences between the treatment groups, when analysed against the control. This identified conditions with a significant difference in cell metabolic activity (alamarBlue™) and cell viability (Trypan Blue). Results Results showed that cell metabolism was not severely affected up to 48°C/150 seconds, while cells in the 58°C group died. Similar results were shown using Trypan Blue and calcein analysis for cell viability. No significant difference in apoptosis and necrosis of the cells was observed when human MSCs treated at 48°C/150 seconds were compared with the control group. Conclusions The study suggests that human MSCs seeded onto allograft can be exposed to temperatures up to 48°C for 150 seconds. Exposure to this temperature for this time period is unlikely to occur during impaction allograft surgery when cement is used. Therefore, in many situations, the addition of human MSCs to cemented impaction grafting may be carried out without detrimental effects to the cells. Furthermore, previous studies have shown that this can enhance new bone formation and repair the defects in revision situations

    3D printing and electrospinning of composite hydrogels for cartilage and bone tissue engineering

    Get PDF
    Injuries of bone and cartilage constitute important health issues costing the National Health Service billions of pounds annually, in the UK only. Moreover, these damages can become cause of disability and loss of function for the patients with associated social costs and diminished quality of life. The biomechanical properties of these two tissues are massively different from each other and they are not uniform within the same tissue due to the specific anatomic location and function. In this perspective, tissue engineering (TE) has emerged as a promising approach to address the complexities associated with bone and cartilage regeneration. Tissue engineering aims at developing temporary three-dimensional multicomponent constructs to promote the natural healing process. Biomaterials, such as hydrogels, are currently extensively studied for their ability to reproduce both the ideal 3D extracellular environment for tissue growth and to have adequate mechanical properties for load bearing. This review will focus on the use of two manufacturing techniques, namely electrospinning and 3D printing, that present promise in the fabrication of complex composite gels for cartilage and bone tissue engineering applications

    Material Loss at the Head Taper Junction of the Metal-on-Metal Pinnacle Total Hip Replacement

    Get PDF
    Introduction The ASR XL (DePuy) total hip replacement (THR) is a notable example of a modern metal-on-metal (MOM) implant design that has demonstrated unacceptable survival rates, leading to its recall by the manufacturer; national joint registries have reported revision rates at 7 years of 40% when paired with the Corail stem [1]. The ASR XL THR has a considerably greater risk of revision than the ASR resurfacing hip, which used the same bearing design. This suggests that material loss at the head-stem junction may be responsible for the greater percentage of THR failures observed in this design. The Pinnacle MOM-THR (DePuy) however used the same Corail stem as the ASR XL THR but demonstrated better clinical results, with revision rates of less than 10% at 7 years [1]. The ASR XL and MOM Pinnacle are two designs that have been widely used in hip replacement surgery. The reasons for the differences in the failure rates of the two designs are not fully understood. Comparing the mechanisms of failure of both hips will help surgeons understand whether patients with MOM Pinnacle hips will experience the same types of problems as with those seen with the ASR XL. The aims of this retrieval study were to investigate the significance of differences between the ASR XL and MOM Pinnacle in relation to: (1) pre-revision whole blood Co/Cr ratios, (2) visual evidence of taper corrosion, (3) volumetric material loss at the bearing surfaces and (4) volumetric material loss at the taper surfaces. Methods This study involved a series of failed MOM hips consisting of the ASR XL (n=30) and Pinnacle (n=30), all that had been used with a Corail stem. The bearing material in each design was cobalt-chromium and the Corail stem is of a cementless titanium 12/14 design. The ASR XL and Pinnacle had a median head diameter of 47mm (39-55) and 36mm (36-40) respectively, and a median time to revision of 38.5 months (12-74) and 55 months (14-86) respectively. Pre-revision whole blood metal ion levels were collected for each Table 1 summarises patient and implant data for the hips in this study. The female taper surfaces of all 60 heads were examined macroscopically and microscopically to assess the severity of corrosion. Each surface was graded with a score of between 1 (no corrosion) and 4 (severe corrosion) using a well-published scoring system, which has been shown to be statistically reliable. A Zeiss Prismo (Carl Zeiss Ltd, Rugby, UK) coordinate measuring machine (CMM) was used to determine the volume of material loss at the cup and head bearing surfaces. Up to 300,000 data points were collected using a 2mm ruby stylus that was translated along 400 polar scan lines on the surface. The raw data was used to map regions of material loss by comparing with the unworn geometry of the bearing. A Talyrond 365 (Hobson, Leicester, UK) roundness measuring machine was used to measure the volumetric material loss at each of the head taper surfaces. Published protocols were used to take a series of 180 vertical traces along the taper surface using a 5μm diamond stylus; worn and unworn regions were mapped and used to calculate material loss. Neither the volumetric measurement data nor corrosion scores were normally distributed. Therefore non-parametric tests were performed to assess the statistical significance of differences between the two designs in relation to the parameters under investigation in this study. Results Both the whole blood Co ion levels and the Co/Cr ratios, Figure 1, of the ASR XL hips were significantly greater than the Pinnacles (p<0.05). There was no significant difference between the whole blood Cr ion levels between the two designs (p=0.0542). 18 of the ASR XL hips presented evidence of edge wearing of the cup, compared with 14 Pinnacle hips; this difference was not significant (p=0.438). The length of the stem trunnion contact engagement length with the taper was approximated as being 10.5mm for both designs. The median time to revision of the ASR XL hips was significantly less than the Pinnacle hips (p<0.01). There was visual evidence of corrosion in 93% (n=28) and 90% (n=27) of head tapers for the ASR XLs and Pinnacles respectively. Moderate to severe corrosion was observed in 67% (n=20) of ASR XLs compared to 60% (n=18) of Pinnacles. There was however no statistically significant difference between the scores of the two groups (p=0.927). Figure 2 presents the distribution of material loss rates for the bearing and taper surfaces of the two designs in this study. The median total bearing surface (combined cup and head) rate of material loss for the ASR XL and Pinnacle hips was 4.45mm3/year (0.32-22.85) and 4.03mm3/year (0.87-62.12) respectively. There was no significant difference between the two groups (p=0.928). The median material loss rate at the taper surfaces of the ASR XL and Pinnacle hips was 0.62mm3/year (0-4.20) and 0.30mm3/year (0-3.12); this difference was not significant (p=0.198). Discussion The work of this study presents comparisons of retrieval findings between the ASR XL and Pinnacle MOM-THRs; these hip designs were two of the most commonly implanted in patients worldwide. The significantly greater whole blood Co/Cr ratios found in the ASR XL group compared to the Pinnacle group are of interest. It is speculated that a Co/Cr ratio of greater than 1 may be an indicator of corrosion of an implant whereby more Cr ions are retained on the surface, whilst comparatively more Co ions are released into the blood. In the current study we found wear rates at the bearing surfaces of both designs to be comparable, suggesting that the significantly greater Co/Cr ratios in the ASR XL hips must be due to greater corrosion at the taper junction than the Pinnacles. Although the ASR XL hips had been implanted for a significantly shorter period of time, our visual assessment of the corrosion of the taper junctions found that corrosion scores were comparable between the two designs; indeed, a marginally greater number of ASR XL tapers had evidence of moderate to severe corrosion. This finding, coupled with the elevated Co/Cr ratios suggests that the ASR XL design is more susceptible to corrosion at the taper junction than the Pinnacle hip. We found that the median rate of material loss at the ASR XL taper was over twice that of the Pinnacle taper. Whilst not statistically significant, this difference may be due to a greater risk of corrosion at this interface in the ASR XL design. The differences in material loss and corrosion that were observed at the taper junctions may be explained by considering the larger head sizes of the ASR XL hips in comparison to the Pinnacles. It has previously been shown that increasing head size is correlated with greater visual evidence of corrosion and that increased frictional torque along the taper junction due a larger head diameter can increase the risk of fretting-corrosion. It is suggested therefore that the combination of the larger head sizes of the ASR XLs coupled with the comparatively short, rough surface of the Corail trunnion results in a cumulative effect leading to greater corrosion at the taper junction. Significance The results of the study suggest that the combination of (1) increased frictional torque in the larger ASR XLs and (2) the rough Corail trunnion surface, results in greater corrosion at the taper junction in comparison to the Pinnacle hips; this helps to explain the higher risk of revision in this hip design
    • …