5,378 research outputs found

    Variation in Emission and Absorption Lines and Continuum Flux by Orbital Phase in Vela X-1

    Full text link
    High resolution spectral studies were undertaken at orbital phases 0, 0.25 and 0.5 on the high-mass X-ray binary (HMXB) Vela X-1 using archival Chandra data. We present (a) the first detailed analysis of the multiple strong narrow emission lines present in phase 0.5 (b) an analysis of the absorption of the continuum in phase 0.5, and (c) the first detection of narrow emission and absorption lines in phase 0.25. Multiple fluorescent and H-and He-like emission lines in the band 1.6 - 20 Angstrom in eclipse are partially obscured at phase 0.25 by the X-ray continuum. The phase 0.25 spectrum displays 3 triplets, 2 with a blue-shifted resonance (r) line in absorption and the intercombination (i) and forbidden (f) lines in emission, and shows in absorption other blue-shifted lines seen in emission in eclipse. At phase 0.5 the soft X-ray continuum diminishes revealing an "eclipse-like" spectrum, however line flux values are around 13-fold those in eclipse. We conclude the narrow emission lines in Vela X-1 become apparent when the continuum is blocked from line of sight, either by eclipse or by scattering and/or absorption from a wake or cloud. The H-and He-like lines arise in warm photoionised regions in the stellar wind, while the fluorescent lines (including a Ni K alpha line) are produced in cooler clumps of gas outside these regions. Absorption of the 5-13 Angstrom continuum at phase 0.5 may be caused by an accretion wake comprised of dense stagnant photoionized plasma inside a Stromgren zone. Multiple fluorescent emission lines may be a common feature of the supergiant category of HMXBs.Comment: 29 pages, 7 figures, accepted for publication in the Astronomical Journa

    Inadvertent Percutaneous Endoscopic Gastrostomy Tube Placement through the Transverse Colon to the Stomach Causing Intractable Diarrhea: A Case Report

    Get PDF
    Background. Among patients with chronic disease, percutaneous endoscopic gastrostomy (PEG) tubes are a common mechanism to deliver enteral feedings to patients unable to feed by mouth. While several cases in the literature describe difficulties with and complications of the initial placement of the PEG, few studies have documented the effects of a delayed diagnosis of a misplaced tube. Methods. This case study reviews the hospitalization of an 82 year old male with an inadvertent placement of a PEG tube through the transverse colon. Photos of the placement in the stomach as well as those of the follow up colonoscopy, and a recording of the episodes of diarrhea during the hospitalization were made. Results. The records of this patient reveal complaints of gastrointestinal distress and diarrhea immediately after placement of the tube. Placement in the stomach was verified by endoscopy, with discovery of the tube only after a follow up colonoscopy. The tube remained in place after this discovery, and was removed weeks after the diarrhea was unsuccessfully treated with antibiotics. After tube removal, the patient recovered well and was sent home

    Time-dependent quantum many-body theory of identical bosons in a double well: Early time ballistic interferences of fragmented and number entangled states

    Full text link
    A time-dependent multiconfigurational self-consistent field theory is presented to describe the many-body dynamics of a gas of identical bosonic atoms confined to an external trapping potential at zero temperature from first principles. A set of generalized evolution equations are developed, through the time-dependent variational principle, which account for the complete and self-consistent coupling between the expansion coefficients of each configuration and the underlying one-body wave functions within a restricted two state Fock space basis that includes the full effects of the condensate's mean field as well as atomic correlation. The resulting dynamical equations are a classical Hamiltonian system and, by construction, form a well-defined initial value problem. They are implemented in an efficient numerical algorithm. An example is presented, highlighting the generality of the theory, in which the ballistic expansion of a fragmented condensate ground state is compared to that of a macroscopic quantum superposition state, taken here to be a highly entangled number state, upon releasing the external trapping potential. Strikingly different many-body matter-wave dynamics emerge in each case, accentuating the role of both atomic correlation and mean-field effects in the two condensate states.Comment: 16 pages, 5 figure

    On Entropy Function for Supersymmetric Black Rings

    Full text link
    The entropy function for five-dimensional supersymmetric black rings, which are solutions of U(1)3U(1)^{3} minimal supergravity, is calculated via both on-shell and off-shell formalism. We find that at the tree level, the entropy function obtained from both perspectives can reproduce the Bekenstein-Hawking entropy. We also compute the higher order corrections to the entropy arising form five-dimensional Gauss-Bonnet term as well as supersymmetric R2R^{2} completion respectively and compare the results with previous microscopic calculations.Comment: 17 pages, no figure, JHEP3 style, to appear in JHEP

    Top quark associated production of topcolor pions at hadron colliders

    Get PDF
    We investigate the associated production of a neutral physical pion with top quarks in the context of topcolor assisted technicolor. We find that single-top associated production does not yield viable rates at either the Tevatron or LHC. tt-associated production at the Tevatron is suppressed relative to Standard Model ttH, but at the LHC is strongly enhanced and would allow for easy observation of the main decay channels to bottom quarks, and possible observation of the decay to gluons.Comment: 13 pages, 4 figures, submitted to PR

    Parsing cyclothymic disorder and other specified bipolar spectrum disorders in youth

    Get PDF
    © 2018 Elsevier B.V. Objective: Most studies of pediatric bipolar disorder (BP) combine youth who have manic symptoms, but do not meet criteria for BP I/II, into one “not otherwise specified” (NOS) group. Consequently, little is known about how youth with cyclothymic disorder (CycD) differ from youth with BP NOS. The objective of this study was to determine whether youth with a research diagnosis of CycD (RDCyc) differ from youth with operationalized BP NOS. Method: Participants from the Course and Outcome of Bipolar Youth study were evaluated to determine whether they met RDCyc criteria. Characteristics of RDCyc youth and BP NOS youth were compared at baseline, and over eight-years follow-up. Results: Of 154 youth (average age 11.96 (3.3), 42% female), 29 met RDCyc criteria. RDCyc youth were younger (p =.04) at baseline. Over follow-up, RDCyc youth were more likely to have a disruptive behavior disorder (p =.01), and were more likely to experience irritability (p =.03), mood reactivity (p =.02), and rejection sensitivity (p =.03). BP NOS youth were more likely to develop hypomania (p =.02), or depression (p =.02), and tended to have mood episodes earlier in the eight-year follow-up period. Limitations: RDCyc diagnoses were made retrospectively and followed stringent criteria, which may highlight differences that, under typical clinical conditions and more vague criteria, would not be evident. Conclusion: There were few differences between RDCyc and BP NOS youth. However, the ways in which the groups diverged could have implications; chronic subsyndromal mood symptoms may portend a severe, but ultimately non-bipolar, course. Longer follow-up is necessary to determine the trajectory and outcomes of CycD symptoms

    Clinical Applications of Electron Microscopy in the Analysis of Collagenous Biomaterials

    Get PDF
    Scanning and transmission electron microscopy are of clinical value in assessing the interaction between biomaterials and ingrowing tissues. Ultrastructural information allows the clinician and biomaterials specialist to determine events occurring during wound healing and the biocompatibility of prosthetic devices. This paper reviews some of the experimental and clinical studies done in our laboratory on the use of natural and reconstituted collagen as replacements for connective tissues. Consideration is given to collagen flakes used for the treatment of dermal ulcers, a collagen fiber prosthesis used for tendon and ligament replacement, the effects of chemical preservatives on cartilage used for replacement of tissues during plastic surgery and the growth and orientation of nerve cells on reconstituted collagen fibers. Our results show that reconstituted collagen can be prepared into prosthetic devices which encourage cell attachment and orientation thereby facilitating healing of injured tissues. Furthermore chemical preservation of cartilagenous tissues kills chondrocytes resulting in eventual resorption by inflammatory cells
    corecore