7 research outputs found

    Ultrasonography-based 2D motion-compensated HIFU sonication integrated with reference-free MR temperature monitoring: a feasibility study ex vivo

    No full text
    Magnetic resonance imaging (MRI) and ultrasonography have been used simultaneously in this ex vivo study for the image-guidance of high intensity focused ultrasound (HIFU) treatment in moving tissue. A ventilator-driven balloon produced periodic and non-rigid (i.e. breathing-like) motion patterns in phantoms. MR-compatible ultrasound (US) imaging enabled near real-time 2D motion tracking based on optical flow detection, while near-harmonic reference-free proton resonance frequency shift (PRFS) MR thermometry (MRT) was used to monitor the thermal buildup on line. Reference-free MRT was applied to gradient-echo echo-planar imaging phase maps acquired at the frame rate of 250 to 300 ms/slice with voxel size 1.25×1.25×5 mm(3). The MR-US simultaneous imaging was completely free of mutual interferences while minor RF interferences from the HIFU device were detected in the far field of the US images. The effective duty-cycle of the HIFU sonication was close to 100 % and no off-interval was required to temporally decouple it from the ultrasonography. The motion compensation of the HIFU sonication was achieved with an 8 Hz frame rate and sub-millimeter spatial accuracy, both for single-focus mode and for an iterated multi-foci line scan. Near harmonic reference-less PRFS MRT delivered motion-robust thermal maps perpendicular or parallel to the HIFU beam (0.7 °C precision, 0.5 °C absolute accuracy). Out-of-plane motion compensation was not addressed in this study

    Experimental methods for improved spatial control of thermal lesions in magnetic resonance-guided focused ultrasound ablation

    No full text
    Magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU, or MRgFUS) is a hybrid technology that was developed to provide efficient and tolerable thermal ablation of targeted tumors or other pathologic tissues, while preserving the normal surrounding structures. Fast 3-D ablation strategies are feasible with the newly available phased-array HIFU transducers. However, unlike fixed heating sources for interstitial ablation (radiofrequency electrode, microwave applicator, infra-red laser applicator), HIFU uses propagating waves. Therefore, the main challenge is to avoid thermo-acoustical adverse effects, such as energy deposition at reflecting interfaces and thermal drift of the focal lesion toward the near field. We report here our investigations on some novel experimental solutions to solve, or at least to alleviate, these generally known tolerability problems in HIFU-based therapy. Online multiplanar MR thermometry was the main investigational tool extensively used in this study to identify the problems and to assess the efficacy of the tested solutions. We present an improved method to cancel the beam reflection at the exit window (i.e., tissue-to-air interface) by creating a multilayer protection, to dissipate the residual HIFU beam by bulk scattering. This study evaluates selective de-activation of transducer elements to reduce the collateral heating at bone surfaces in the far field, mainly during automatically controlled volumetric ablation. We also explore, using hybrid US/MR simultaneous imaging, the feasibility of using disruptive boiling at the focus, both as a far-field self-shielding technique and as an enhanced ablation strategy (i.e., boiling core controlled HIFU ablation)

    Reference-free PRFS MR-thermometry using near-harmonic 2-D reconstruction of the background phase

    No full text
    Proton resonance frequency shift (PRFS) MR thermometry (MRT) is the generally preferred method for monitoring thermal ablation, typically implemented with gradient-echo (GRE) sequences. Standard PRFS MRT is based on the subtraction of a temporal reference phase map and is, therefore, intrinsically sensitive to tissue motion (including deformation) and to external perturbation of the magnetic field. Reference-free (or reference-less) PRFS MRT has been previously described by Rieke and was based on a 2-D polynomial fit performed on phase data from outside the heated region, to estimate the background phase inside the region of interest. While their approach was undeniably a fundamental progress in terms of robustness against tissue motion and magnetic perturbations, the underlying mathematical formalism requires a thick unheated border and may be subject to numerical instabilities with high order polynomials. A novel method of reference-free PRFS MRT is described here, using a physically consistent formalism, which exploits mathematical properties of the magnetic field in a homogeneous or near-homogeneous medium. The present implementation requires as input the MR GRE phase values along a thin, nearly-closed and unheated border. This is a 2-D restriction of a classic Dirichlet problem, working on a slice per slice basis. The method has been validated experimentally by comparison with the “ground truth” data, considered to be the standard PRFS method for static ex vivo tissue. “Zero measurement” of the gradient-echo phase baseline was performed in healthy volunteer liver with rapid acquisition (300 ms/image). In vivo data acquired in sheep liver during MR-guided high intensity focused ultrasound (MRgHIFU) sonication were post-processed as proof of applicability in a therapeutic scenario. Bland and Altman mean absolute difference between the novel method and the “ground truth” thermometry in ex vivo static tissue ranged between 0.069 °C and 0.968 °C, compared to the inherent “white” noise SD of 0.23 °C. The accuracy and precision of the novel method in volunteer liver were found to be on average 0.13 °C and respectively 0.65 °C while the inherent “white” noise SD was on average 0.51 °C. The method was successfully applied to large ROIs, up to 6.2 cm inner diameter, and the computing time per slice was systematically less than 100 ms using C++. The current limitations of reference-free PRFS thermometry originate mainly from the need to provide a nearly-closed border, where the MR phase is artifact-free and the tissue is unheated, plus the potential need to reposition that border during breathing to track the motion of the anatomic zone being monitored.A reference-free PRFS thermometry method based on the theoretical framework of harmonic functions is described and evaluated here. The computing time is compatible with online monitoring during local thermotherapy. The current reference-free MRT approach expands the workflow flexibility, eliminates the need for respiratory triggers, enables higher temporal resolution, and is insensitive to unique-event motion of tissue

    ARFI-prepared MRgHIFU in liver: simultaneous mapping of ARFI-displacement and temperature elevation, using a fast GRE-EPI sequence

    No full text
    MR acoustic radiation force imaging (ARFI) is an elegant adjunct to MR-guided high intensity focused ultrasound for treatment planning and optimization, permitting in situ assessment of the focusing and targeting quality. The thermal effect of high intensity focused ultrasound pulses associated with ARFI measurements is recommended to be monitored on line, in particular when the beam crosses highly absorbent structures or interfaces (e.g., bones or air-filled cavities). A dedicated MR sequence is proposed here, derived from a segmented gradient echo-echo planar imaging kernel by adding a bipolar motion encoding gradient with interleaved alternating polarities. Temporal resolution was reduced to 2.1 s, with in-plane spatial resolution of 1 mm. MR-ARFI measurements were executed during controlled animal breathing, with trans-costal successively steered foci, to investigate the spatial modulation of the focus intensity and the targeting offset. ARFI-induced tissue displacement measurements enabled the accurate localization, in vivo, of the high intensity focused ultrasound focal point in sheep liver, with simultaneous monitoring of the temperature elevation. ARFI-based precalibration of the focal point position was immediately followed by trans-costal MR-guided high intensity focused ultrasound ablation, monitored with a conventional proton resonance frequency shift MR thermometry sequence. The latter MR thermometry sequence had spatial resolution and geometrical distortion identical with the ARFI maps, hence no coregistration was required

    Magnetic resonance-guided shielding of prefocal acoustic obstacles in focused ultrasound therapy: application to intercostal ablation in liver

    No full text
    The treatment of liver cancer is a major public health issue because the liver is a frequent site for both primary and secondary tumors. Rib heating represents a major obstacle for the application of extracorporeal focused ultrasound to liver ablation. Magnetic resonance (MR)-guided external shielding of acoustic obstacles (eg, the ribs) was investigated here to avoid unwanted prefocal energy deposition in the pathway of the focused ultrasound beam