88 research outputs found

    Bilateral Diabetic Knee Neuroarthropathy in a Forty-Year-Old Patient.

    Get PDF
    Diabetic osteoarthropathy is a rare cause of neuropathic joint disease of the knee; bilateral involvement is even more exceptional. Diagnosis is often made late due to its unspecific symptoms and appropriate surgical management still needs to be defined, due to lack of evidence because of the disease's low incidence. We report the case of a forty-year-old woman with history of diabetes type I who developed bilateral destructive Charcot knee arthropathy. Bilateral total knee arthroplasty was performed in order to achieve maximal functional outcome. Follow-up was marked by bilateral tibial periprosthetic fractures treated by osteosynthesis with a satisfactory outcome. The diagnosis of Charcot arthropathy should always be in mind when dealing with atraumatic joint destruction in diabetic patients. Arthroplasty should be considered as an alternative to arthrodesis in bilateral involvement in young patients

    Advanced septic arthritis of the shoulder treated by a two-stage arthroplasty.

    Get PDF
    The usual treatment of septic shoulder arthritis consists of arthroscopic or open lavage and debridement. However, in patients with advanced osteoarthritic changes and/or massive rotator cuff tendon tears, infection eradication can be challenging to achieve and the functional outcome is often not satisfying even after successful infection eradication. In such cases a two-stage approach with initial resection of the native infected articular surfaces, implantation of a cement spacer before final treatment with a total shoulder arthroplasty in a second stage is gaining popularity in recent years with the data in literature however being still limited. To evaluate the results of a short interval two-stage arthroplasty approach for septic arthritis with concomitant advanced degenerative changes of the shoulder joint. We retrospectively included five consecutive patients over a five-year period and evaluated the therapeutic management and the clinical outcome assessed by disability of the arm, shoulder and hand (DASH) score and subjective shoulder value (SSV). All procedures were performed through a deltopectoral approach and consisted in a debridement and synovectomy, articular surface resection and insertion of a custom made antibiotic enriched cement spacer. Shoulder arthroplasty was performed in a second stage. Mean age was 61 years (range, 47-70 years). Four patients had previous surgeries ahead of the septic arthritis. All patients had a surgical debridement ahead of the index procedure. Mean follow-up was 13 mo (range, 6-24 mo). Persistent microbiological infection was confirmed in all five cases at the time of the first stage of the procedure. The shoulder arthroplasties were performed 6 to 12 wk after insertion of the antibiotic-loaded spacer. There were two hemi and three reverse shoulder arthroplasties. Infection was successfully eradicated in all patients. The clinical outcome was satisfactory with a mean DASH score and SSV of 18.4 points and 70% respectively. Short interval two-stage approach for septic shoulder arthritis is an effective treatment option. It should nonetheless be reserved for selected patients with advanced disease in which lavage and debridement have failed

    Maximum diameter measurements of aortic aneurysms on axial CT images after endovascular aneurysm repair: sufficient for follow-up?

    Full text link
    PURPOSE: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. MATERIALS AND METHODS: Forty-nine consecutive patients (73 ± 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. RESULTS: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). CONCLUSION: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine

    Cementless short-stem total hip arthroplasty in the elderly patient - is it a safe option?: a prospective multicentre observational study.

    Get PDF
    Due to its bone preserving philosophy, short-stem total hip arthroplasty (THA) has primarily been recommended for young and active patients. However, there may be benefits for elderly patients given a less invasive operative technique due to the short curved implant design. The purpose of this study was to compare the clinical and radiological outcomes as well as perioperative complications of a calcar-guided short stem between a young (&lt; 60 years) and a geriatric (&gt; 75 years) population. Data were collected in a total of 5 centers, and 400 short-stems were included as part of a prospective multicentre observational study between 2010 and 2014 with a mean follow-up of 49.2 months. Preoperative femur morphology was analysed using the Dorr classification. Clinical and radiological outcomes were assessed in both groups as well as perioperative complications, rates and reasons for stem revision. No differences were found for the mean visual analogue scale (VAS) values of rest pain, load pain, and satisfaction, whereas Harris Hip Score (HHS) was slightly better in the young group. Comparing both groups, none of the radiological parameters that were assessed (stress-shielding, cortical hypertrophy, radiolucency, osteolysis) reached differences of statistical significance. While in young patients aseptic loosening is the main cause of implant failure, in the elderly group particularly postoperative periprosthetic fractures due to accidental fall have to be considered to be of high risk. The incidence of periprosthetic fractures was found to be 0% in Dorr type A femurs, whereas in Dorr types B and C fractures occurred in 2.1 and 22.2% respectively. Advanced age alone is not necessarily to be considered as contra-indications for calcar-guided short-stem THA, although further follow-up is needed. However, markedly reduced bone quality with femur morphology of Dorr type C seems to be associated with increased risk for postoperative periprosthetic fractures, thus indication should be limited to Dorr types A and B. German Clinical Trials Register; DRKS00012634 , 07.07.2017 (retrospectively registered)

    Inter-scan variability of coronary artery calcium scoring assessed on 64-multidetector computed tomography vs. dual-source computed tomography: a head-to-head comparison

    Get PDF
    Aims Coronary artery calcium (CAC) scoring has emerged as a tool for risk stratification and potentially for monitoring response to risk factor modification. Therefore, repeat measurements should provide robust results and low inter-scanner variability for allowing meaningful comparison. The purpose of this study was to investigate inter-scanner variability of CAC for Agatston, volume, and mass scores by head-to-head comparison using two different cardiac computed tomography scanners: 64-detector multislice CT (MSCT) and 64-slice dual-source CT (DSCT). Methods and results Thirty patients underwent CAC measurements on both 64-MSCT (GE LightSpeed XT scanner: 120 kV, 70 mAs, 2.5 mm slices) and 64-DSCT (Siemens Somatom Definition: 120 kV, 80 mAs, 3 mm slices) within <100 days (0-97). Retrospective intra-scan comparison revealed an excellent correlation. The excellent intra-scan (inter-observer) agreement was documented by narrow limits of agreement and a correlation coefficient of variation (COV) of r ≥ 0.99 (P < 0.001) for all CAC scores with a low COV for both scanners (64-MSCT/64-DSCT), i.e. Agatston (2.0/2.1%), mass (3.0/2.0%), and volume (4.7/3.9%). Inter-scanner comparison revealed larger Bland-Altman (BA) limits of agreement, despite high correlation (r ≥ 0.97) for all scores, with COV at 15.1, 21.6, and 44.9% for Agatston, mass, and volume scores. The largest BA limits were observed for volume scores (−1552.8 to 574.2), which was massively improved (−241.0 to 300.4, COV 11.5%) after reanalysing the 64-DSCT scans (Siemens) with GE software/workstation (while Siemens software/workstation does not allow cross-vendor analysis). Phantom measurements confirmed overestimation of volume scores by ‘syngo Ca-Scoring' (Siemens) software which should therefore be reviewed (vendor has been notified). Conclusion Intra- and inter-scan agreement of CAC measurement in a given data set is excellent. Inter-scanner variability is reasonable, particularly for Agatston units in the clinically most relevant range <1000. The use of different software solutions has a greater influence particularly on volume scores than the use of different scanner type

    Impact of cardiac hybrid single-photon emission computed tomography/computed tomography imaging on choice of treatment strategy in coronary artery disease

    Get PDF
    Aims Cardiac hybrid imaging by fusing single-photon emission computed tomography (SPECT) myocardial perfusion imaging with coronary computed tomography angiography (CCTA) provides important complementary diagnostic information for coronary artery disease (CAD) assessment. We aimed at assessing the impact of cardiac hybrid imaging on the choice of treatment strategy selection for CAD. Methods and results Three hundred and eighteen consecutive patients underwent a 1 day stress/rest 99mTc-tetrofosmin SPECT and a CCTA on a separate scanner for evaluation of CAD. Patients were divided into one of the following three groups according to findings in the hybrid images obtained by fusing SPECT and CCTA: (i) matched finding of stenosis by CCTA and corresponding reversible SPECT defect; (ii) unmatched CCTA and SPECT finding; (iii) normal finding by both CCTA and SPECT. Follow-up was confined to the first 60 days after hybrid imaging as this allows best to assess treatment strategy decisions including the revascularization procedure triggered by its findings. Hybrid images revealed matched, unmatched, and normal findings in 51, 74, and 193 patients. The revascularization rate within 60 days was 41, 11, and 0% for matched, unmatched, and normal findings, respectively (P< 0.001 for all inter-group comparisons). Conclusion Cardiac hybrid imaging with SPECT and CCTA provides an added clinical value for decision making with regard to treatment strategy for CA

    High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization.

    Full text link
    PURPOSE: To compare image quality and radiation dose of high-pitch computed tomography angiography(CTA) of the aortic valve-aortic root complex with and without prospective ECG-gating compared to a retrospectively ECG-gated standard-pitch acquisition. MATERIALS AND METHODS: 120 patients(mean age 68 +/- 13 years) were examined using a 128-slice dual-source CT system using prospectively ECG-gated high-pitch(group A; n = 40), non-ECG-gated high-pitch(group B; n = 40) or retrospectively ECG-gated standard-pitch(C; n = 40) acquisition techniques. Image quality of the aortic root, valve and ascending aorta including the coronary ostia was assessed by two independent readers. Image noise was measured, radiation dose estimates were calculated. RESULTS: Interobserver agreement was good(kappa = 0.64-0.78). Image quality was diagnostic in 38/40 patients(group A), 37/40(B) and 38/40(C) with no significant difference in number of patients with diagnostic image quality among all groups (p = 0.56). Significantly more patients showed excellent image quality in group A compared to groups B and C(each, p < 0.01). Average image noise was significantly different between all groups(p < 0.05). Mean radiation dose estimates in groups A and B(each; 2.4 +/- 0.3 mSv) were significantly lower compared to group C(17.5 +/- 4.4 mSv; p < 0.01). CONCLUSION: High-pitch dual-source CTA provides diagnostic image quality of the aortic valve-aortic root complex even without ECG-gating at 86% less radiation dose when compared to a standard-pitch ECG-gated acquisition

    Technical principles of computed tomography in patients with congenital heart disease

    Get PDF
    Cardiac magnetic resonance imaging and echocardiography are often the primary imaging techniques for many patients with congenital heart disease (CHD). However, with modern generations of CT systems and recent advances in temporal and spatial resolution, cardiac CT has been gaining an increasing reputation in the field of cardiac imaging and in the evaluation of patients with congenital heart disease. The CT imaging protocol depends on the suspected cardiac defect, the type of previous surgical repair, and the patient’s age and level of cooperation. Various strategies are available for reducing radiation exposure, which is of utmost importance particularly in paediatric patients. A sequential segmental analysis is a commonly used approach to analysing congenital heart defects. Familiarity of the performing radiologist with dedicated CT protocols, the complex anatomy, morphology and terminology of CHD, as well as with the surgical procedures used to correct congenital abnormalities is a prerequisite for correct diagnosis

    Impact of cardiac hybrid single-photon emission computed tomography/computed tomography imaging on choice of treatment strategy in coronary artery disease

    Get PDF
    Aims Cardiac hybrid imaging by fusing single-photon emission computed tomography (SPECT) myocardial perfusion imaging with coronary computed tomography angiography (CCTA) provides important complementary diagnostic information for coronary artery disease (CAD) assessment. We aimed at assessing the impact of cardiac hybrid imaging on the choice of treatment strategy selection for CAD. Methods and results Three hundred and eighteen consecutive patients underwent a 1 day stress/rest (99m)Tc-tetrofosmin SPECT and a CCTA on a separate scanner for evaluation of CAD. Patients were divided into one of the following three groups according to findings in the hybrid images obtained by fusing SPECT and CCTA: (i) matched finding of stenosis by CCTA and corresponding reversible SPECT defect; (ii) unmatched CCTA and SPECT finding; (iii) normal finding by both CCTA and SPECT. Follow-up was confined to the first 60 days after hybrid imaging as this allows best to assess treatment strategy decisions including the revascularization procedure triggered by its findings. Hybrid images revealed matched, unmatched, and normal findings in 51, 74, and 193 patients. The revascularization rate within 60 days was 41, 11, and 0% for matched, unmatched, and normal findings, respectively (P< 0.001 for all inter-group comparisons). Conclusion Cardiac hybrid imaging with SPECT and CCTA provides an added clinical value for decision making with regard to treatment strategy for CAD

    Magnetic resonance imaging pattern recognition in childhood bilateral basal ganglia disorders

    Get PDF
    Bilateral basal ganglia abnormalities on MRI are observed in a wide variety of childhood disorders. MRI pattern recognition can enable rationalization of investigations and also complement clinical and molecular findings, particularly confirming genomic findings and also enabling new gene discovery. A pattern recognition approach in children with bilateral basal ganglia abnormalities on brain MRI was undertaken in this international multicentre cohort study. Three hundred and five MRI scans belonging to 201 children with 34 different disorders were rated using a standard radiological scoring proforma. In addition, literature review on MRI patterns was undertaken in these 34 disorders and 59 additional disorders reported with bilateral basal ganglia MRI abnormalities. Cluster analysis on first MRI findings from the study cohort grouped them into four clusters: Cluster 1—T2-weighted hyperintensities in the putamen; Cluster 2—T2-weighted hyperintensities or increased MRI susceptibility in the globus pallidus; Cluster 3—T2-weighted hyperintensities in the globus pallidus, brainstem and cerebellum with diffusion restriction; Cluster 4—T1-weighted hyperintensities in the basal ganglia. The 34 diagnostic categories included in this study showed dominant clustering in one of the above four clusters. Inflammatory disorders grouped together in Cluster 1. Mitochondrial and other neurometabolic disorders were distributed across clusters 1, 2 and 3, according to lesions dominantly affecting the striatum (Cluster 1: glutaric aciduria type 1, propionic acidaemia, 3-methylglutaconic aciduria with deafness, encephalopathy and Leigh-like syndrome and thiamine responsive basal ganglia disease associated with SLC19A3), pallidum (Cluster 2: methylmalonic acidaemia, Kearns Sayre syndrome, pyruvate dehydrogenase complex deficiency and succinic semialdehyde dehydrogenase deficiency) or pallidum, brainstem and cerebellum (Cluster 3: vigabatrin toxicity, Krabbe disease). The Cluster 4 pattern was exemplified by distinct T1-weighted hyperintensities in the basal ganglia and other brain regions in genetically determined hypermanganesemia due to SLC39A14 and SLC30A10. Within the clusters, distinctive basal ganglia MRI patterns were noted in acquired disorders such as cerebral palsy due to hypoxic ischaemic encephalopathy in full-term babies, kernicterus and vigabatrin toxicity and in rare genetic disorders such as 3-methylglutaconic aciduria with deafness, encephalopathy and Leigh-like syndrome, thiamine responsive basal ganglia disease, pantothenate kinase-associated neurodegeneration, TUBB4A and hypermanganesemia. Integrated findings from the study cohort and literature review were used to propose a diagnostic algorithm to approach bilateral basal ganglia abnormalities on MRI. After integrating clinical summaries and MRI findings from the literature review, we developed a prototypic decision-making electronic tool to be tested using further cohorts and clinical practice
    corecore