6 research outputs found

    High-Density, Stretchable, All-Solid-State Microsupercapacitor Arrays

    No full text
    We report on the successful fabrication of stretchable microsupercapacitor (MSC) arrays on a deformable polymer substrate that exhibits high electrochemical performance even under mechanical deformation such as bending, twisting, and uniaxial strain of up to 40%. We designed the deformable substrate to minimize the strain on MSCs by adopting a heterogeneous structure consisting of stiff PDMS islands (on which MSCs are attached) and a soft thin film (mixture of Ecoflex and PDMS) between neighboring PDMS islands. Finite element method analysis of strain distribution showed that an almost negligible strain of 0.47% existed on the PDMS islands but a concentrated strain of 107% was present on the soft thin film area under a uniaxial strain of 40%. The use of an embedded interconnection of the liquid metal Galinstan helped simplify the fabrication and provided mechanical stability under deformation. Furthermore, double-sided integration of MSCs increased the capacitance to twice that of MSCs on a conventional planar deformable substrate. In this study, planar-type MSCs with layer-by-layer assembled hybrid thin film electrodes of MWNT/Mn<sub>3</sub>O<sub>4</sub> and PVA-H<sub>3</sub>PO<sub>4</sub> electrolyte were fabricated; when they are integrated into a circuit, these MSCs increase the output voltage beyond the potential of the electrolyte used. Therefore, various LEDs that require high voltages can be operated under a high uniaxial strain of 40% without any decrease in their brightness. The results obtained in this study demonstrate the high potential of our stretchable MSC arrays for their application as embedded stretchable energy storage devices in bioimplantable and future wearable nanoelectronics

    Biaxially Stretchable, Integrated Array of High Performance Microsupercapacitors

    No full text
    We report on the fabrication of a biaxially stretchable array of high performance microsupercapacitors (MSCs) on a deformable substrate. The deformable substrate is designed to suppress local strain applied to active devices by locally implanting pieces of stiff polyethylene terephthalate (PET) films within the soft elastomer of Ecoflex. A strain suppressed region is formed on the top surface of the deformable substrate, below which PET films are implanted. Active devices placed within this region can be isolated from the strain. Analysis of strain distribution by finite element method confirms that the maximum strain applied to MSC in the strain suppressed region is smaller than 0.02%, while that on the Ecoflex film is larger than 250% under both uniaxial strain of 70% and biaxial strain of 50%. The all-solid-state planar MSCs, fabricated with layer-by-layer deposited multiwalled carbon nanotube electrodes and patterned ionogel electrolyte of poly(ethylene glycol) diacrylate and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide having high-potential windows, are dry-transferred onto the deformable substrate and electrically connected in series and parallel <i>via</i> embedded liquid metal interconnection and Ag nanowire contacts. Liquid metal interconnection, formed by injecting liquid metal into the microchannel embedded within the substrate, can endure severe strains and requires no additional encapsulation process. This formed MSC array exhibits high energy and power density of 25 mWh/cm<sup>3</sup> and 32 W/cm<sup>3</sup>, and stable electrochemical performance up to 100% uniaxial and 50% biaxial stretching. The high output voltage of the MSC array is used to light micro-light-emitting diode (μ-LED) arrays, even under strain conditions. This work demonstrates the potential application of our stretchable MSC arrays to wearable and bioimplantable electronics with a self-powered system

    Biaxial Stretchability and Transparency of Ag Nanowire 2D Mass-Spring Networks Prepared by Floating Compression

    No full text
    Networks of silver nanowires (Ag NWs) have been considered as promising materials for stretchable and transparent conductors. Despite various improvements of their optoelectronic and electromechanical properties over the past few years, Ag NW networks with a sufficient stretchability in multiple directions that is essential for the accommodation of the multidirectional strains of human movement have seldom been reported. For this paper, biaxially stretchable, transparent conductors were developed based on 2D mass-spring networks of wavy Ag NWs. Inspired by the traditional papermaking process, the 2D wavy networks were produced by floating Ag NW networks on the surface of water and subsequently applying biaxial compression to them. It was demonstrated that this floating-compression process can reduce the friction between the Ag NW–water interfaces, providing a uniform and isotropic in-plane waviness for the networks without buckling or cracking. The resulting Ag NW networks that were transferred onto elastomeric substrates successfully acted as conductors with an excellent transparency, conductivity, and electromechanical stability under a biaxial strain of 30%. The strain sensors that are based on the prepared conductors demonstrated a great potential for the enhanced performances of future wearable devices

    Stretchable Array of Highly Sensitive Pressure Sensors Consisting of Polyaniline Nanofibers and Au-Coated Polydimethylsiloxane Micropillars

    No full text
    We report on the facile fabrication of a stretchable array of highly sensitive pressure sensors. The proposed pressure sensor consists of the top layer of Au-deposited polydimethylsiloxane (PDMS) micropillars and the bottom layer of conductive polyaniline nanofibers on a polyethylene terephthalate substrate. The sensors are operated by the changes in contact resistance between Au-coated micropillars and polyaniline according to the varying pressure. The fabricated pressure sensor exhibits a sensitivity of 2.0 kPa<sup>–1</sup> in the pressure range below 0.22 kPa, a low detection limit of 15 Pa, a fast response time of 50 ms, and high stability over 10000 cycles of pressure loading/unloading with a low operating voltage of 1.0 V. The sensor is also capable of noninvasively detecting human-pulse waveforms from carotid and radial artery. A 5 × 5 array of the pressure sensors on the deformable substrate, which consists of PDMS islands for sensors and the mixed thin film of PDMS and Ecoflex with embedded liquid metal interconnections, shows stable sensing of pressure under biaxial stretching by 15%. The strain distribution obtained by the finite element method confirms that the maximum strain applied to the pressure sensor in the strain-suppressed region is less than 0.04% under a 15% biaxial strain of the unit module. This work demonstrates the potential application of our proposed stretchable pressure sensor array for wearable and artificial electronic skin devices

    Encapsulated, High-Performance, Stretchable Array of Stacked Planar Micro-Supercapacitors as Waterproof Wearable Energy Storage Devices

    No full text
    We report the fabrication of an encapsulated, high-performance, stretchable array of stacked planar micro-supercapacitors (MSCs) as a wearable energy storage device for waterproof applications. A pair of planar all-solid-state MSCs with spray-coated multiwalled carbon nanotube electrodes and a drop-cast UV-patternable ion-gel electrolyte was fabricated on a polyethylene terephthalate film using serial connection to increase the operation voltage of the MSC. Additionally, multiple MSCs could be vertically stacked with parallel connections to increase both the total capacitance and the areal capacitance owing to the use of a solid-state patterned electrolyte. The overall device of five parallel-connected stacked MSCs, a microlight-emitting diode (μ-LED), and a switch was encapsulated in thin Ecoflex film so that the capacitance remained at 82% of its initial value even after 4 d in water; the μ-LED was lit without noticeable decrease in brightness under deformation including bending and stretching. Furthermore, an Ecoflex encapsulated oximeter wound around a finger was operated using the stored energy of the MSC array attached to the hand (even in water) to give information on arterial pulse rate and oxygen saturation in the blood. This study suggests potential applications of our encapsulated MSC array in wearable energy storage devices especially in water
    corecore