49 research outputs found

    Treatment of Fournier's Gangrene with Combination of Vacuum-Assisted Closure Therapy, Hyperbaric Oxygen Therapy, and Protective Colostomy

    Get PDF
    Fournier's gangrene is a rare process which affects soft tissue in the genital and perirectal area. It can also progress to all different stages of sepsis, and abdominal compartment syndrome can be one of its complications. Two patients in septic shock due to Fournier gangrene were admitted to the Intensive Care Unit of Emergency Department. In both cases, infection started from the scrotum and the necrosis quickly involved genitals, perineal, and inguinal regions. Patients were treated with surgical debridement, protective colostomy, hyperbaric oxygen therapy, and broad-spectrum antibacterial chemotherapy. Vacuum-assisted closure (VAC) therapy was applied to the wound with the aim to clean, decontaminate, and avoid abdominal compartmental syndrome development. Both patients survived and were discharged from Intensive Care Unit after hyperbaric oxygen therapy cycles and abdominal closure

    Time needed to achieve completeness and accuracy in bedside lung ultrasound reporting in Intensive Care Unit

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The use of lung ultrasound (LUS) in ICU is increasing but ultrasonographic patterns of lung are often difficult to quantify by different operators. The aim of this study was to evaluate the accuracy and quality of LUS reporting after the introduction of a standardized electronic recording sheet.</p> <p>Methods</p> <p>Intensivists were trained for LUS following a teaching programme. From April 2008, an electronic sheet was designed and introduced in ICU database in order to uniform LUS examination reporting. A mark from 0 to 24 has been given for each exam by two senior intensivists not involved in the survey. The mark assigned was based on completeness of a precise reporting scheme, concerning the main finding of LUS. A cut off of 15 was considered sufficiency.</p> <p>Results</p> <p>The study comprehended 12 months of observations and a total of 637 LUS. Initially, although some improvement in the reports completeness, still the accuracy and precision of examination reporting was below 15. The time required to reach a sufficient quality was 7 months. A linear trend in physicians progress was observed.</p> <p>Conclusions</p> <p>The uniformity in teaching programme and examinations reporting system permits to improve the level of completeness and accuracy of LUS reporting, helping physicians in following lung pathology evolution.</p

    Optical issues for the diagnostic stations for the ELI-NP compton gamma source

    Get PDF
    A high brightness electron Linac is being built in the Compton Gamma Source at the ELI Nuclear Physics facility in Romania. To achieve the design luminosity, a train of 32 bunches, 16 ns spaced, with a nominal charge of 250 pC will collide with the laser beam in the interaction point. Electron beam spot size is measured with optical transition radiation (OTR) profile monitors. In order to measure the beam properties, the optical radiation detecting system must have the necessary accuracy and resolution. This paper deals with the studies of different optic configurations to achieve the magnification, resolution and accuracy in order to measure very small beam (below 30 μm) or to study the angular distribution of the OTR and therefore the energy of the beam. Several configurations of the optical detection line will be studied both with simulation tools (e.g. Zemax) and experimentally. The paper will deal also with the sensibility of optic system (in terms of depth of field, magnification and resolution) to systematic error

    Feasibility of inter-hospital transportation using extra-corporeal membrane oxygenation (ECMO) support of patients affected by severe swine-flu(H1N1)-related ARDS

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To describe the organization of an ECMO-centre from triage by telephone to the phase of inter-hospital transportation with ECMO of patients affected by H1N1-induced ARDS, describing techniques and equipment used.</p> <p>Methods</p> <p>From September 2009 to January 2010, 18 patients with H1N1-induced ARDS were referred to our ECMO-centre from other hospitals. Six patients had contraindications to treatment with ECMO and remained in the local hospital. Twelve patients were transported to our centre and were included in this study. Four patients were transported on ECMO (Group A) and eight on conventional ventilation (Group B). The groups were compared on the basis of adverse events during transport, clinical characteristics and outcome.</p> <p>Results</p> <p>The PaO2/FiO2 ratio was lower in the patients of Group A (46.8 vs 89.7 [median]) despite the PEEP values being higher (15.0 vs 8.5 [median]). The Murray score was higher in Group A (3.50 vs 2.75 [median]). During the transfer there were no significant complications noted in Group A, whereas two patients in Group B were reported with hypoxia (SpO2 < 90%). One patient in Group A died. All the other patients of the two groups have been discharged from hospital.</p> <p>Conclusions</p> <p>The creation of an ECMO team, with various experts in the treatment of ARDS, assured a safe transfer of patients with severe hypoxia, over long distances, when in other cases they wouldn't have been be transportable.</p

    Extracorporeal life support for management of refractory cardiac or respiratory failure: initial experience in a tertiary centre

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Extracorporeal Life Support (ECLS) and extracorporeal membrane oxygenation (ECMO) have been indicated as treatment for acute respiratory and/or cardiac failure. Here we describe our first year experience of in-hospital ECLS activity, the operative algorithm and the protocol for centralization of adult patients from district hospitals.</p> <p>Methods</p> <p>At a tertiary referral trauma center (Careggi Teaching Hospital, Florence, Italy), an ECLS program was developed from 2008 by the Emergency Department and Heart and Vessel Department ICUs. The ECLS team consists of an intensivist, a cardiac surgeon, a cardiologist and a perfusionist, all trained in ECLS technique. ECMO support was applied in case of severe acute respiratory distress syndrome (ARDS) not responsive to conventional treatments. The use of veno-arterial (V-A) ECLS for cardiac support was reserved for cases of cardiac shock refractory to standard treatment and cardiac arrests not responding to conventional resuscitation.</p> <p>Results</p> <p>A total of 21 patients were treated with ECLS during the first year of activity. Among them, 13 received ECMO for ARDS (5 H1N1-virus related), with a 62% survival. In one case of post-traumatic ARDS, V-A ECLS support permitted multiple organ donation after cerebral death was confirmed. Patients treated with V-A ECLS due to cardiogenic shock (N = 4) had a survival rate of 50%. No patients on V-A ECLS support after cardiac arrest survived (N = 4).</p> <p>Conclusions</p> <p>In our centre, an ECLS Service was instituted over a relatively limited period of time. A strict collaboration between different specialists can be regarded as a key feature to efficiently implement the process.</p
    corecore