654 research outputs found

    Sequential prostate MRI reporting in men on active surveillance: initial experience of a dedicated PRECISE software program

    Get PDF
    BACKGROUND AND OBJECTIVES: There is interest in using sequential multiparametric magnetic resonance imaging (mpMRI) to assess men on active surveillance (AS) for prostate cancer. The Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) recommendations propose standardised reporting mpMRI data for these men. This includes accurate size measurements of lesions over time, but such approach is time consuming for the radiologist and there is a strong need of dedicated tools to report serial scans in a systematic manner. We present the results from an initial validation cohort using dedicated PRECISE reporting software to allow automated comparison between sequential scans on AS. MATERIALS AND METHODS: We retrospectively analysed baseline and follow-up scans of 20 men randomised to 6 months of daily dutasteride (n = 10) or placebo (n = 10) from the MAPPED trial. Men underwent 3T mpMRI at baseline and after 6 months, and a dedicated radiologist reported the scans using both a widespread commercially-available platform (Osirix®) and a semi-automated dedicated PRECISE reporting tool (MIM®). Tumour volume by planimetry in all sequences and conspicuity on diffusion-weighted imaging were assessed. Reporting time was recorded, and we used the Wilcoxon test for statistical analysis. RESULTS: Median tumour volumes and conspicuity were similar using both approaches. The reporting time of the follow-up scan was quicker using the PRECISE reporting workflow both in the whole population (12'33″ vs 10'52″; p = 0.005) and in the dutasteride arm (15'50″ vs 12'59″; p = 0.01). A structured report including clinical and imaging data was generated according to the PRECISE recommendations and a comparison table between lesion characteristics at baseline and follow-up scans was also included. CONCLUSION: We conclude that a dedicated PRECISE reporting tool for sequential scans in men on AS results in a significant reduction in the reporting time and allows the radiologist to easily compare scans over time. This tool will help with our understanding of the natural history of mpMRI changes during AS

    Longitudinal Image Registration with Temporal-Order and Subject-Specificity Discrimination

    Get PDF
    Morphological analysis of longitudinal MR images plays a key role in monitoring disease progression for prostate cancer patients, who are placed under an active surveillance program. In this paper, we describe a learning-based image registration algorithm to quantify changes on regions of interest between a pair of images from the same patient, acquired at two different time points. Combining intensity-based similarity and gland segmentation as weak supervision, the population-data-trained registration networks significantly lowered the target registration errors (TREs) on holdout patient data, compared with those before registration and those from an iterative registration algorithm. Furthermore, this work provides a quantitative analysis on several longitudinal-data-sampling strategies and, in turn, we propose a novel regularisation method based on maximum mean discrepancy, between differently-sampled training image pairs. Based on 216 3D MR images from 86 patients, we report a mean TRE of 5.6 mm and show statistically significant differences between the different training data sampling strategies

    Mouse tracking to explore motor inhibition processes in go/no-go and stop signal tasks

    Get PDF
    Response inhibition relies on both proactive and reactive mechanisms that exert a synergic control on goal-directed actions. It is typically evaluated by the go/no-go (GNG) and the stop signal task (SST) with response recording based on the key-press method. However, the analysis of discrete variables (i.e., present or absent responses) registered by key-press could be insufficient to capture dynamic aspects of inhibitory control. Trying to overcome this limitation, in the present study we used a mouse tracking procedure to characterize movement profiles related to proactive and reactive inhibition. A total of fifty-three participants performed a cued GNG and an SST. The cued GNG mainly involves proactive control whereas the reactive component is mainly engaged in the SST. We evaluated the velocity profile from mouse trajectories both for responses obtained in the Go conditions and for inhibitory failures. Movements were classified as one-shot when no corrections were observed. Multi-peaked velocity profiles were classified as non-one-shot. A higher proportion of one-shot movements was found in the SST compared to the cued GNG when subjects failed to inhibit responses. This result suggests that proactive control may be responsible for unsmooth profiles in inhibition failures, supporting a differentiation between these tasks

    Standardisation of prostate multiparametric MRI across a hospital network: a London experience.

    Get PDF
    OBJECTIVES: National guidelines recommend prostate multiparametric (mp) MRI in men with suspected prostate cancer before biopsy. In this study, we explore prostate mpMRI protocols across 14 London hospitals and determine whether standardisation improves diagnostic quality. METHODS: An MRI physicist facilitated mpMRI set-up across several regional hospitals, working together with experienced uroradiologists who judged diagnostic quality. Radiologists from the 14 hospitals participated in the assessment and optimisation of prostate mpMRI image quality, assessed according to both PiRADSv2 recommendations and on the ability to "rule in" and/or "rule out" prostate cancer. Image quality and sequence parameters of representative mpMRI scans were evaluated across 23 MR scanners. Optimisation visits were performed to improve image quality, and 2 radiologists scored the image quality pre- and post-optimisation. RESULTS: 20/23 mpMRI protocols, consisting of 111 sequences, were optimised by modifying their sequence parameters. Pre-optimisation, only 15% of T2W images were non-diagnostic, whereas 40% of ADC maps, 50% of high b-value DWI and 41% of DCE-MRI were considered non-diagnostic. Post-optimisation, the scores were increased with 80% of ADC maps, 74% of high b-value DWI and 88% of DCE-MRI to be partially or fully diagnostic. T2W sequences were not optimised, due to their higher baseline quality scores. CONCLUSIONS: Targeted intervention at a regional level can improve the diagnostic quality of prostate mpMRI protocols, with implications for improving prostate cancer detection rates and targeted biopsies

    Apparent diffusion coefficient by diffusion-weighted magnetic resonance imaging as a sole biomarker for staging and prognosis of gastric cancer

    Get PDF
    Objective: To investigate the role of apparent diffusion coefficient (ADC) from diffusion-weighted magnetic resonance imaging (DW-MRI) when applied to the 7th TNM classification in the staging and prognosis of gastric cancer (GC). Methods: Between October 2009 and May 2014, a total of 89 patients with non-metastatic, biopsy proven GC underwent 1.5T DW-MRI, and then treated with radical surgery. Tumor ADC was measured retrospectively and compared with final histology following the 7th TNM staging (local invasion, nodal involvement and according to the different groups — stage I, II and III). Kaplan-Meier curves were also generated. The follow-up period is updated to May 2016. Results: Median follow-up period was 33 months and 45/89 (51%) deaths from GC were observed. ADC was significantly different both for local invasion and nodal involvement (P<0.001). Considering final histology as the reference standard, a preoperative ADC cut-off of 1.80×10–3 mm2 /s could distinguish between stages I and II and an ADC value of ≤1.36×10–3 mm2 /s was associated with stage III (P<0.001). Kaplan-Meier curves demonstrated that the survival rates for the three prognostic groups were significantly different according to final histology and ADC cut-offs (P<0.001). Conclusions: ADC is different according to local invasion, nodal involvement and the 7th TNM stage groups for GC, representing a potential, additional prognostic biomarker. The addition of DW-MRI could aid in the staging and risk stratification of GC

    Interaction Between Climatic, Environmental, and Demographic Factors on Cholera Outbreaks in Kenya

    Get PDF
    Background: Cholera remains an important public health concern in developing countries including Kenya where 11,769 cases and 274 deaths were reported in 2009 according to the World Health Organization (WHO). This ecological study investigates the impact of various climatic, environmental, and demographic variables on the spatial distribution of cholera cases in Kenya. Methods: District-level data was gathered from Kenya’s Division of Disease Surveillance and Response, the Meteorological Department, and the National Bureau of Statistics. The data included the entire population of Kenya from 1999 to 2009. Results: Multivariate analyses showed that districts had an increased risk of cholera outbreaks when a greater proportion of the population lived more than five kilometers from a health facility (RR: 1.025 per 1% increase; 95% CI: 1.010, 1.039), bordered a body of water (RR: 5.5; 95% CI: 2.472, 12.404), experienced increased rainfall from October to December (RR: 1.003 per 1 mm increase; 95% CI: 1.001, 1.005), and experienced decreased rainfall from April to June (RR: 0.996 per 1 mm increase; 95% CI: 0.992, 0.999). There was no detectable association between cholera and population density, poverty, availability of piped water, waste disposal methods, rainfall from January to March, or rainfall from July to September. Conclusion: Bordering a large body of water, lack of health facilities nearby, and changes in rainfall were significantly associated with an increased risk of cholera in Kenya

    Lorentz- and CPT-violating models for neutrino oscillations

    Get PDF
    A class of calculable global models for neutrino oscillations based on Lorentz and CPT violation is presented. One simple example matches established neutrino data from accelerator, atmospheric, reactor, and solar experiments, using only two degrees of freedom instead of the usual five. A third degree of freedom appears in the model, and it naturally generates the MiniBooNE low-energy anomalies. More involved models in this class can also accommodate the LSND anomaly and neutrino-antineutrino differences of the MINOS type. The models predict some striking signals in various ongoing and future experiments.Comment: 17 pages two-column REVTe
    • …
    corecore