16 research outputs found

    Left cervical and circumflex aortic arch with aberrant right subclavian artery arising from a Kommerell diverticulum: A rare vascular ring

    No full text
    We report a rare case of vascular ring due to a left cervical circumflex aortic arch with aberrant right subclavian artery arising from a Kommerell diverticulum. This is a very rare case of vascular ring in a newborn with stridor and stenosis of the left pulmonary artery. A cardiac catheterization and an angio-computed tomography scan were helpful to clarify the diagnosis. The surgical correction was performed with division of the arterial duct, reimplantation of the right subclavian artery, aortic and tracheal suspension, and pulmonary arterial plasty. The patient was asymptomatic at discharge and 1-year follow-up

    Impact of pregnancy on natural history of systemic right ventricle in women with transposition of the great arteries

    No full text
    In the recent years, the pregnancy trend among women with Congenital Heart Disease (CHD) has increased; this has leaded to a growing demand for specialized care both in mother and in children. Although pregnancy is often well tolerated, maternal CHD may affect in some cases a maladaptive hemodynamic response carrying additional risks of cardiovascular events like arrhythmias, heart failure and, in rare cases, death. The impaired utero-placental perfusion due to maternal cardiac status may result in placental dysfunction, which may be associated with fetal growth restriction, preeclampsia, premature birth and perinatal morbidity. Systemic Right Ventricle (SRV) is one of the main conditions under which pregnancy is challenging. The sub-aortic position of morphological Right Ventricle (RV) is "physiologically" predisposed to fail at the adult age and may be potentially inadequate to support the hemodynamic stress of the pregnancy. Current literature about pregnancy in women with SRV consists of small retrospective series not providing conclusive evidence about the feasibility of a successful pregnancy outcomes. In addition, the long-term effects of pregnancy on SVR are not still adequately investigated and it remains unclear if maternal complications reported are due to pregnancy or to natural history of SVR. The aim of this paper is to offer a critical review of the knowledges at regard and to provide a practice update on the risk assessment and the pregnancy management in women with SRV in order to support the decision making and to optimize outcomes in these patients

    Patent foramen ovale with complex anatomy: Comparison of two different devices (Amplatzer Septal Occluder device and Amplatzer PFO Occluder device 30/35)

    No full text
    Background: Patent foramen ovale (PFO) closure after a cryptogenic cerebral ischemic event is a routinely procedure. The most used device is Amplatzer™ PFO Occluder 25 mm, but PFOs with complex anatomy require larger device for closure. We compared Amplatzer™ Septal Occluder (ASO) device versus Amplatzer™ PFO Occluder 30 or 35 mm (A-PFO 30/35) about the safety of procedure and the presence of residual shunt during the follow-up. Methods: From June 2002 to July 2016, 355 patients (pts) with PFO undergone closure at our institution. Among these ones, 70 pts (19.7%) had a PFO with complex anatomy and a single device with greater diameter was implanted. In these cases, the following devices were used: Gore® Septal Occluder (GSO) in 4 pts; ASO device in 33 pts (group I) and A-PFO 30/35 in 33 pts (group II). Patients treated with GSO device were excluded by our analysis. Results: Comparing group I and group II, there weren't complications during the procedures. Two patients of group II were lost at follow-up. At last follow-up, 1 pt of group I (3%) and 10 pts of group II (32.3%) had a residual shunt (p < 0.01). 7 of 10 pts of group II and the only 1 of group I with residual shunt underwent a complete closure by Amplatzer™ Vascular Plug (AVP) devices. Conclusions: ASO devices and A-PFO 30/35 devices are both safe to close complex PFO; but A-PFO 30/35 is associated with a more incidence of residual shunt

    Novel echocardiographic score to predict duct-dependency after percutaneous relief of critical pulmonary valve stenosis/atresia

    No full text
    Objectives This study aimed to identify clinical, hemodynamic, or echocardiographic predictive features of persistent duct-dependency of pulmonary circulation (PDDPC) after effective percutaneous relief of pulmonary atresia with the intact ventricular septum (PA-IVS) or critical pulmonary stenosis (CPS). Methods From 2010 to 2021, 55 neonates with PA-IVS or CPS underwent percutaneous right ventricle (RV) decompression at our Institution. After successfully relief of critical obstruction, 27 patients (group I) showed PDDPC, whereas RV was able to support the pulmonary circulation in the remaining 28 patients (group II). Clinical, hemodynamic, and echocardiographic features of these two groups were compared. Results No significant difference in clinical and hemodynamic data was found between the groups, although the group I had a lower oxygen saturation at hospital admission. However, tricuspid valve (TV) diameter <8.8 mm, TV z-score <- 2.12, tricuspid/mitral valve annular ratio <.78, pulmonary valve diameter <6.7 mm, pulmonary valve z-score <- 1.17, end-diastolic RV area <1.35 cm(2), end-systolic right atrium area >2.45 cm(2), percentage amount of interatrial right-to-left shunt >69.5%, moderate/severe tricuspid regurgitation, RV systolic pressure >42.5 mmHg, tricuspid E/E ' ratio >6.6 showed each significant predictive value of PDDPC. These parameters were used to build a composite echocardiographic score (PDDPC-score), assigning one point each above the respective cut-off value. A score >= 4.00 showed high sensitivity (100%) and specificity (86%) in predicting PDDPC. Conclusion Clinical and hemodynamic features fail to predict the short-term fate of the pulmonary circulation after successful treatment of PA-IVS/CPS. However, a simple, composite echocardiographic score is useful to predict PDDPC and could be crucial in the management of this frail subset of patients

    [Percutaneous treatment of complex post-myocardial infarction ventricular septal defect: case report and literature review]

    No full text
    Post-myocardial infarction (MI) ventricular septal defects (VSD) are a rare but life-threatening complication of acute MI, with very high mortality rates even if timely approached by surgical repair. Transcatheter closure is an attractive alternative to surgery. However, this option is currently deemed challenging and often unsuitable in complex VSD. We report the case of a young woman in poor hemodynamic conditions due to a complex post-MI VSD. A two-step percutaneous VSD closure was successfully performed adopting a patient-tailored approach based on a throughout knowledge of the anatomic and functional picture using both commercially available dedicated and off-label devices

    Transcatheter closure of fenestrated atrial septal aneurysm in children: Feasibility and long-term results

    No full text
    Background To date, extensive experience in transcatheter closure of fenestrated atrial septal aneurysm (ASA) in the pediatric population is limited. Methods To report on procedural feasibility, efficacy, and long-term outcome, we enrolled all children submitted to an attempt of transcatheter closure of fenestrated ASA at two, large volume, pediatric cardiology units (Naples and Massa, Italy) between April 2000 to May 2020. Results This retrospective study included 139 patients (median age 9 years [range 2-18] and weight 36 kg [range 10-102]); 19 (13.7%) children were <= 20 kg (range 10-20) and 14 (10.1%) were <= 5 years old. Single perforation was observed in 28 patients (20.1%), while 111 patients (79.9%) had multifenestrated ASA. The median size of the main defect was 15 mm (range 6-34) and 25 patients (18%) had a defect >= 20 mm. The procedural success rate was 99% (95% confidence interval [CI]: 94.9-99.8) using a single device in 75 (69%), two devices in 31 (28%), and three devices in 3 (3%) cases. Early minor adverse events (AEs) occurred in four patients (2.8%). Late minor AEs were recorded in one patient (0.7%) over a median follow-up of 5 years ([range 0-18 years; total 890.2 person-years, and with 30 patients (22%) followed >= 10 years). Neither mortality nor major AEs were recorded. Freedom from AEs was 99.1% at 10-15 years (95% CI: 93.5-99.8%), without any difference according to atrial septum anatomy or patient age and weight. Conclusion Transcatheter closure of fenestrated ASA is technically feasible and effective in children with excellent long-term outcomes

    Advances in Percutaneous Patent Foramen Ovale Closure: From the Procedure to the Echocardiographic Guidance

    No full text
    Percutaneous patent foramen ovale (PFO) closure by traditional, double disc occluder devices was shown to be safe for patients with PFO, and more effective than prolonged medical therapy in preventing recurrent thromboembolic events. The novel suture-mediated "deviceless" PFO closure system overcomes most of the risks and limitations associated with the traditional PFO occluders, appearing to be feasible in most interatrial septum anatomies, even if data about its long-term effectiveness and safety are still lacking. The aim of the present review was to provide to the reader the state of the art about the traditional and newer techniques of PFO closure, focusing both on the procedural aspects and on the pivotal role of transesophageal echocardiography (TEE) in patient's selection, peri-procedural guidance, and post-interventional follow-up
    corecore