628 research outputs found
Reliability of Early Fetal Echocardiography for Congenital Heart Disease Detection: A Preliminary Experience and Outcome Analysis of 102 Fetuses to Demonstrate the Value of a Clinical Flow-Chart Designed for At-Risk Pregnancy Management
Early fetal echocardiography (EFEC) is a fetal cardiac ultrasound analysis performed between the 12th and 16th week of pregnancy (compared with the usual 18-22 weeks). In the last 10 years, the introduction of “aneuploidy sonographic markers” in screening for cardiac defects has led to a shift from late second to end of the first trimester or beginning of the second trimester of pregnancy for specialist fetal echocardiography. In this prospective study, early obstetric screening was performed between January 2014 and October 2015, using “aneuploidy sonographic markers” following SIEOG Guidelines 2014. These parameters were then collected and strategically combined in an evaluation score to select the group of pregnancies for performing EFEC, in accordance with the American Society of Echocardiography guidelines for fetal Echocardiography. All second-level examinations were performed transabdominally using a 3D convex volumetric probe with frequency range of 4-8 MHz (Accuvix – Samsung). The outcome data included transabdominal fetal echocardiography from 18 weeks to term and after birth. Overall, 99 pregnant women in the first trimester underwent EFEC (95 singleton and 4 twin pregnancies). Specifically, 30 fetuses were evaluated for extra-cardiac anomalies evidenced by obstetric screening (30%), 25 for family history of congenital heart diseases (25%), 8 for family history of genetic-linked diseases (8%), 4 for heart diseases suspected by obstetric screening (4%) and 19 by normal screening (19%). Was detected 11 (10.7%) CHD, when EFEC detected CHD, were compared to those performed later in pregnancy (18 weeks GA-term), a high degree of diagnosis correspondence was evidenced. The higher sensitivity value of EFEC vs late-FE, in comparison with the post-natal value, coupled with the high EFEC specificity shown vs both the end points, enabled us to consider it as a really reliable diagnostic technology, at least in perienced hands. The introduction of a key combination of the more sensitive obstetric and cardiologic variables should facilitate the formulation of a possible flow-chart as a guide for CHD at-risk pregnancies
Role of fetal MRI in the evaluation of isolated and non-isolated corpus callosum dysgenesis: results of a cross-sectional study
PURPOSE:
The aims of this study were to characterize isolated and non-isolated forms of corpus callosum dysgenesis (CCD) at fetal magnetic resonance imaging (MRI) and to identify early predictors of associated anomalies.
METHODS:
We retrospectively analyzed 104 fetuses with CCD undergoing MRI between 2006 and 2016. Corpus callosum, cavum septi pellucidi, biometry, presence of ventriculomegaly, gyration anomalies, cranio-encephalic abnormalities and body malformations were evaluated. Results of genetic tests were also recorded.
RESULTS:
At MRI, isolated CCD was 26.9%, the rest being associated to other abnormalities. In the isolated group, median gestational age at MRI was lower in complete agenesis than in hypoplasia (22 vs 28 weeks). In the group with additional findings, cortical dysplasia was the most frequently associated feature (P = 0.008), with a more frequent occurrence in complete agenesis (70%) versus other forms; mesial frontal lobes were more often involved than other cortical regions (P = 0.006), with polymicrogyria as the most frequent cortical malformation (40%). Multivariate analysis confirmed the association between complete agenesis and cortical dysplasia (odds ratio = 7.29, 95% confidence interval 1.51-35.21).
CONCLUSIONS:
CCD is often complicated by other intra-cranial and extra-cranial findings (cortical dysplasias as the most prevalent) that significantly affect the postnatal prognosis. The present study showed CCD with associated anomalies as more frequent than isolated (73.1%). In isolated forms, severe ventriculomegaly was a reliable herald of future appearance of associated features
No COVID-19 pandemic impact on incidence and clinical presentation of celiac disease in Italian children
Aim: We aimed to evaluate the impact of Coronavirus Disease-19 (COVID-19) pandemic on the incidence and clinical presentation of celiac disease (CD) in children.MethodsThe diagnoses of CD were compared between the COVID-19 pandemic (from April 2020 to March 2022) and the pre-pandemic period (from April 2018 to March 2020) in three Italian Paediatric Gastroenterology centres (Varese, Como, Catanzaro). Electronic patient records were reviewed and additional information were collected through parental interview. The diagnosis of CD was made according to ESPGHAN criteria. SARS-CoV-2 infection was diagnosed based on pre-vaccination positive serum antibodies or nasopharyngeal swabs. Z test and chi-square were used for statistical analysis.ResultsThe overall number of paediatric diagnosis of CD did not differ between the two years pre-pandemic and pandemic periods (177 and 172 cases) in the three Italian participating centres. Clinical presentation of CD was also similar throughout the study periods. SARS-CoV-2 infection has been documented in 10.6% of children but only in 5.8% of these occurred before CD diagnosis.ConclusionDifferent to what reported for other autoimmune diseases, the incidence and presenting symptoms of CD in our paediatric population did not change during the COVID-19 pandemic compared to the previous 2 years
Physical and chemical mechanisms involved in adhesion of orthodontic bonding composites: in vitro evaluations
BackgroundBond strength of orthodontic composite is strongly influenced by molecular and structural mechanisms. Aim of this in vitro study was to compare bond strength of light-cure orthodontic composites by measuring debonding forces and evaluating locations of bond failure. Investigations on chemical compositions clarified adhesive behaviors and abilities, exploring effects of ageing processes in this junction materials.MethodsTwelve enamel discs, from human premolars, were randomly coupled to one orthodontic adhesive system (Transbond XT (TM) 3 M UNITEK, USA, Light-Cure Orthodontic Paste, LEONE, Italy and Bisco Ortho Bracket Paste LC, BISCO, Illinois) and underwent to Shear Bond Strength test. Metallic brackets were bonded to twenty-seven human premolar, with one of the adhesive systems, to quantify, at FE-SEM magnifications, after debonding, the residual material on enamel and bracket base surfaces. Raman Spectroscopy analysis was performed on eight discs of each composites to investigate on chemical compositions, before and after accelerated aging procedures in human saliva and sugary drink.ResultsOrthodontic adhesive systems showed similar strength of adhesion to enamel. The breakage of adhesive-adherent bond occurs in TXT at enamel-adhesive interface while in Bisco and Leone at adhesive-bracket interface. Accelerated in vitro aging demonstrated good physical-chemical stability for all composites, Bisco only, was weakly contaminated with respect to the other materials.ConclusionA similar, clinically adequate and acceptable bond strength to enamel for debonding maneuvers was recorded in all orthodontic adhesive systems under examination. No significant chemical alterations are recorded, even in highly critical situations, not altering the initial mechanical properties of materials
Intrapartum foetal heart rate decelerations are physiological adaptations to hypoxia: a critical appraisal of the recent evidence
Electronic intrapartum foetal monitoring (also known as cardiotocography, CTG) is the standard technique to assess the foetal well-being during labour. In the last decade, several researchers have provided useful information regarding the pathophysiology of foetal heart rate (FHR) decelerations, the main CTG feature to cause interpretation disagreement; recent evidence summarized in this paper set new grounds to reconceptualize the “classical” aetiology of intrapartum foetal hypoxia and FHR decelerations. Each deceleration is generated from hypoxia, and it is the dynamic pattern of these decelerations that gives information about the status of metabolic and cardiac adaption mechanism of the foetus. The relationship to uterine contractions or the morphology of deceleration should no longer be used to discriminate a reassuring or non-reassuring CTG trace
An observational study to assess Italian obstetrics providers' knowledge about preventive practices and diagnosis of congenital cytomegalovirus
Congenital cytomegalovirus (cCMV) infection can be easily prevented by hygienic measures. Up to date the majority of the studies in literature highlighted a reduction in cCMV antenatal counseling and its prevention. Our purpose was to evaluate obstetrics providers' knowledge about cCMV infection, management and the behavioral practices to avoid it. This is a cross-sectional survey carried out in Umberto I Hospital, "Sapienza"University of Rome between November 2019 and January 2020. We recruited 148 specialists and residents in Obstetrics and Gynecology through online anonymous multiple-choice 13-questions, 10 min-survey comparing responses between the two groups. A total of 94.6% of all participants said they always prescribe cytomegalovirus (CMV) serum screening: 73.6% of them regularly counsel about preventive practices, with specialists recording higher percentages (85.4 vs. 65.1%, p<0.005). We identified a good knowledge about the diagnostic pathway, but only 58.1% of our population knows the correct time of late amniocentesis. 12.2% of providers do not consider magnetic resonance (MRI) as a complementary exam. Prevention of maternal seroconversion is crucial: even if our data show an acceptable knowledge about antenatal counseling, we encourage clinicians to firmly inform and educate women about behavioral measures
Rescue of Replication-Competent ZIKV Hidden in Placenta-Derived Mesenchymal Cells Long After the Resolution of the Infection
The Zika virus (ZIKV) genome, its negative-strand viral proteins, and virus-like particles were detected in placenta-derived mesenchymal cells (MSCs), indicating that ZIKV persists after virus clearance from maternal blood and can be rescued by in vitro cultivation. We report for the first time the presence of replication-competent ZIKV in MSCs from an asymptomatic woman who acquired infection during pregnancy
- …