352 research outputs found
Expected Sensitivity to Galactic/Solar Axions and Bosonic Super-WIMPs based on the Axio-electric Effect in Liquid Xenon Dark Matter Detectors
We present systematic case studies to investigate the sensitivity of axion
searches by liquid xenon detectors, using the axio-electric effect (analogue of
the photoelectric effect) on xenon atoms. Liquid xenon is widely considered to
be one of the best target media for detection of WIMPs (Weakly Interacting
Massive Particles which may form the galactic dark matter) using nuclear
recoils. Since these detectors also provide an extremely low radioactivity
environment for electron recoils, very weakly-interacting low-mass particles (<
100 keV/c^2), such as the hypothetical axion, could be detected as well - in
this case using the axio-electric effect. Future ton-scale liquid Xe detectors
will be limited in sensitivity only by irreducible neutrino background
(pp-chain solar neutrino and the double beta decay of 136Xe) in the mass range
between 1 and 100 keV/c^2. Assuming one ton-year of exposure, galactic axions
(as non-relativistic dark matter) could be detected if the axio-electric
coupling g_Ae is greater than 10^-14 at 1 keV/c^2 (or $10^-13 at 100 keV/c^2).
Below a few keV/c^2, and independent of the mass, a solar axion search would be
sensitive to a coupling g_Ae ~ 10^-12. This limit will set a stringent upper
bound on axion mass for the DFSV and KSVZ models for the mass ranges m_A < 0.1
eV/c^2 and < 10 eV/c^2, respectively. Vector-boson dark matter could also be
detected for a coupling constant alpha'/alpha > 10^-33 (for mass 1 keV/c^2) or
> 10^-27 (for mass 100 keV/c^2).Comment: 17 pages, 10 figure
Constraining Radon Backgrounds in LZ
The LZ dark matter detector, like many other rare-event searches, will suffer
from backgrounds due to the radioactive decay of radon daughters. In order to
achieve its science goals, the concentration of radon within the xenon should
not exceed Bq/kg, or 20 mBq total within its 10 tonnes. The LZ
collaboration is in the midst of a program to screen all significant components
in contact with the xenon. The four institutions involved in this effort have
begun sharing two cross-calibration sources to ensure consistent measurement
results across multiple distinct devices. We present here five preliminary
screening results, some mitigation strategies that will reduce the amount of
radon produced by the most problematic components, and a summary of the current
estimate of radon emanation throughout the detector. This best estimate totals
mBq, sufficiently low to meet the detector's science goals.Comment: Low Radioactivity Techniques (LRT) 2017 Workshop Proceedings. 6
pages; 3 figure
Radioassay facilities at the STFC Boulby Underground Laboratory
For future low-background particle physics experiments, it will be essential to assay candidate detector materials using an array of assay techniques. To minimise the risk of sample contamination whilst moving between assay techniques, it is also sensible to minimise the distance between assay stations, particularly for non-destructive techniques where the sample may end up being installed into an experiment. The Boulby UnderGround Screening (BUGS) Facility comprises an array of germanium detectors, two XIA UltraLo-1800 surface-alpha counters, two radon emanation detectors and an Agilent ICP-MS system. This article describes each of these systems
FlameNEST: explicit profile likelihoods with the Noble Element Simulation Technique
We present FlameNEST, a framework providing explicit likelihood evaluations in noble element particle detectors using data-driven models from the Noble Element Simulation Technique. FlameNEST provides a way to perform statistical analyses on real data with no dependence on large, computationally expensive Monte Carlo simulations by evaluating the likelihood on an event-by-event basis using analytic probability elements convolved together in a single TensorFlow multiplication. Furthermore, this robust framework creates opportunities for simple inter-collaboration analyses which will be fundamental for the future of experimental dark matter physics
Characterization of the Hamamatsu R11410-10 3-Inch Photomultiplier Tube for Liquid Xenon Dark Matter Direct Detection Experiments
To satisfy the requirements of the next generation of dark matter detectors
based on the dual phase TPC, Hamamatsu, in close collaboration with UCLA, has
developed the R11410-10 photomultipler tube. In this work, we present the
detailed tests performed on this device. High QE (>30%) accompanied by a low
dark count rate (50 Hz at 0.3 PE) and high gain (10^7) with good single PE
resolution have been observed. A comprehensive screening measurement campaign
is ongoing while the manufacturer quotes a radioactivity of 20 mBq/PMT. These
characteristics show the R11410-10 to be particularly suitable for the
forthcoming zero background liquid xenon detectors.Comment: 19 pages, 18 figure
Ultra-low background germanium assay at the Boulby Underground Laboratory
As we move to an era where next generation ultra-low background particle physics experiments begin to be designed and constructed, the ability to assay materials with high sensitivity and at speed with a variety of techniques will be key. This paper describes the Mirion Technologies (Canberra) specialty ultra-low background detectors installed and commissioned at the Boulby Underground Laboratory between 2017 and 2021. The low background levels of the detectors combine with low background shielding and a radon-reduced dry nitrogen purge system to give sensitivity approaching the best in the world without the need for intricate shielding solutions. For an optimised sample geometry, run for 100 d, it would be possible to reach close to 10 μBq kg-1 (10-12 g/g) for background radionuclides of interest in neutrinoless double-beta decay
First measurement of the Head-Tail directional nuclear recoil signature at energies relevant to WIMP dark matter searches
We present first evidence for the so-called Head-Tail asymmetry signature of
neutron-induced nuclear recoil tracks at energies down to 1.5 keV/amu using the
1m^3 DRIFT-IIc dark matter detector. This regime is appropriate for recoils
induced by Weakly Interacting Massive Particle (WIMPs) but one where the
differential ionization is poorly understood. We show that the distribution of
recoil energies and directions induced here by Cf-252 neutrons matches well
that expected from massive WIMPs. The results open a powerful new means of
searching for a galactic signature from WIMPs.Comment: 4 pages, 6 figures, 1 tabl
A New Analysis Method for WIMP searches with Dual-Phase Liquid Xe TPCs
A new data analysis method based on physical observables for WIMP dark matter
searches with noble liquid Xe dual-phase TPCs is presented. Traditionally, the
nuclear recoil energy from a scatter in the liquid target has been estimated by
means of the initial prompt scintillation light (S1) produced at the
interaction vertex. The ionization charge (C2), or its secondary scintillation
(S2), is combined with the primary scintillation in Log(S2/S1) vs. S1 only as a
discrimination parameter against electron recoil background. Arguments in favor
of C2 as the more reliable nuclear recoil energy estimator than S1 are
presented. The new phase space of Log(S1/C2) vs. C2 is introduced as more
efficient for nuclear recoil acceptance and exhibiting superior energy
resolution. This is achieved without compromising the discrimination power of
the LXe TPC, nor its 3D event reconstruction and fiducialization capability, as
is the case for analyses that exploit only the ionization channel. Finally, the
concept of two independent energy estimators for background rejection is
presented: E2 as the primary (based on C2) and E1 as the secondary (based on
S1). Log(E1/E2) vs. E2 is shown to be the most appropriate phase space in which
to evaluate WIMP signal candidates
Observation of the Dependence of Scintillation from Nuclear Recoils in Liquid Argon on Drift Field
We have exposed a dual-phase Liquid Argon Time Projection Chamber (LAr-TPC)
to a low energy pulsed narrowband neutron beam, produced at the Notre Dame
Institute for Structure and Nuclear Astrophysics to study the scintillation
light yield of recoiling nuclei in a LAr-TPC. A liquid scintillation counter
was arranged to detect and identify neutrons scattered in the LAr-TPC target
and to select the energy of the recoiling nuclei.
We report the observation of a significant dependence on drift field of
liquid argon scintillation from nuclear recoils of 11 keV. This observation is
important because, to date, estimates of the sensitivity of noble liquid TPC
dark matter searches are based on the assumption that electric field has only a
small effect on the light yield from nuclear recoils.Comment: v3 updated to reflect published version, including a set of plots for
49.9 keV dat
- …