41 research outputs found
SWIVIT - Swiss video-intubation trial evaluating video-laryngoscopes in a simulated difficult airway scenario: study protocol for a multicenter prospective randomized controlled trial in Switzerland.
BACKGROUND: Video-laryngoscopes are marketed for intubation in difficult airway management. They provide a better view of the larynx and may facilitate tracheal intubation, but there is no adequately powered study comparing different types of video-laryngoscopes in a difficult airway scenario or in a simulated difficult airway situation.
METHODS/DESIGN: The objective of this trial is to evaluate and to compare the clinical performance of three video-laryngoscopes with a guiding channel for intubation (Airtraq?, A. P. Advance?, King Vision?) and three video-laryngoscopes without an integrated tracheal tube guidance (C-MAC?, GlideScope?, McGrath?) in a simulated difficult airway situation in surgical patients. The working hypothesis is that each video-laryngoscope provides at least a 90% first intubation success rate (lower limit of the 95% confidence interval >0.9). It is a prospective, patient-blinded, multicenter, randomized controlled trial in 720 patients who are scheduled for elective surgery under general anesthesia, requiring tracheal intubation at one of the three participating hospitals. A difficult airway will be created using an extrication collar and taping the patients' head on the operating table to substantially reduce mouth opening and to minimize neck movement. Tracheal intubation will be performed with the help of one of the six devices according to randomization. Insertion success, time necessary for intubation, Cormack-Lehane grade and percentage of glottic opening (POGO) score at laryngoscopy, optimization maneuvers required to aid tracheal intubation, adverse events and technical problems will be recorded. Primary outcome is intubation success at first attempt.
DISCUSSION: We will simulate the difficult airway and evaluate different video-laryngoscopes in this highly realistic and clinically challenging scenario, independently from manufacturers of the devices. Because of the sufficiently powered multicenter design this study will deliver important and cutting-edge results that will help clinicians decide which device to use for intubation of the expected and unexpected difficult airway.
TRIAL REGISTRATION: NCT01692535
Simulation-based medical education training improves short and long-term competency in, and knowledge of central venous catheter insertion: A before and after intervention study
Multimodal educational interventions have been shown to improve short-term competency in, and knowledge of central venous catheter (CVC) insertion
Comparison of the Glidescope, the McGrath, the Airtraq and the Macintosh laryngoscopes in simulated difficult airways
SUMMARY: Several indirect laryngoscopes have recently been developed, but relatively few have been formally compared. In this study we evaluated the efficacy and the usability of the Macintosh, the Glidescope, the McGrath and the Airtraq laryngoscopes. Sixty anaesthesia providers (20 staff, 20 residents, and 20 nurses) were enrolled into this study. The volunteers intubated the trachea of a Laerdal SimMan manikin in three simulated difficult airway scenarios. In all scenarios, indirect laryngoscopes provided better laryngeal exposure than the Macintosh blade and appeared to produce less dental trauma. In the most difficult scenario (tongue oedema), the Macintosh blade was associated with a high rate of failure and prolonged intubation times whereas indirect laryngoscopes improved intubation time and rarely failed. Indirect laryngoscopes were judged easier to use than the Macintosh. Differences existed between indirect devices. The Airtraq consistently provided the most rapid intubation. Laryngeal grade views were superior with the Airtraq and McGrath than with the Glidescope
Evaluation of six videolaryngoscopes in 720 patients with a simulated difficult airway: a multicentre randomized controlled trial
Videolaryngoscopes are aggressively marketed, but independent evaluation in difficult airways is scarce. This multicentre, prospective randomized controlled trial evaluates six videolaryngoscopes in patients with a simulated difficult airway