12 research outputs found

    Cast of the Right Bronchial Tree

    No full text

    Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial

    No full text
    Background: Third-generation rotary blood pumps have magnetically levitated rotors that eliminate mechanical wear over the years. Together with their potential for miniaturization, these pumps seem suitable for long-term support of patients with a wide range of body surface areas (BSA). Recently, the novel HVAD pump (HeartWare Inc, Framingham, MA), a miniaturized centrifugal pump with a hydrodynamic, magnetically levitated rotor, became ready for clinical application. Methods: In a multi-institutional trial in Europe and Australia, 23 patients (mean age, 47.9 ± 12 years) in end-stage heart failure were enrolled in 5 centers. The primary end point of the bridge-to-transplant study was survival to heart transplant or survival to 180 days on the device, whichever occurred first. Follow-up data at 1 year are presented. The small size of the device allows for intrapericardial placement of the pump. Results: Implant procedures were generally fast and uneventful. Mean duration of support was 167 ± 143 days (range, 13–425 days), and mean blood flow provided by the pump was 6.1 ± 1.1 liters/min. At the 180-day end point, 2 patients had undergone successful transplant at 157 and 175 days, 2 patients died while on the device, and 19 patients continued pump support for more than 180 days. Actuarial survival after 6 months was 91% and was 86% at the 1-year follow-up. Conclusions: The design of the HVAD pump enables a quick and less invasive implantation. The results to date demonstrate satisfactory long-term survival with excellent quality of life in this cohort of 23 patients of the initial multi-institutional Conformité Européene (CE) mark trial

    Time in therapeutic range significantly impacts survival and adverse events in destination therapy patients

    No full text
    The study aim was to examine the impact time in therapeutic range (TTR, International Normalized Ratio [INR] 2.0-3.0) has on survival and adverse events in patients receiving the HeartWare HVAD System in the ENDURANCE and ENDURANCE Supplemental Trials. Evaluable subjects (n = 495) had \u3e1 INR value recorded 1-24 months postimplant and were categorized as: low TTR (10-39%), moderate TTR (40-69%), and high TTR (≥70%). Baseline characteristics, adverse events, and survival were analyzed. Low TTR patients experienced higher rates of major bleeding (1.69 vs. 0.54 events per patient year [EPPY]; p \u3c 0.001), GI bleeding (1.22 vs. 0.38 EPPY; p \u3c 0.001), stroke (0.47 vs. 0.17 EPPY; p \u3c 0.001), thrombus requiring exchange (0.05 vs. 0.01 EPPY; p = 0.02), infection (1.44 vs. 0.69 EPPY; p \u3c 0.001), and renal dysfunction (0.23 vs. 0.05 EPPY; p \u3c 0.001) compared with high TTR. Moderate TTR had higher rates of major bleeding (0.75 vs. 0.54 EPPY; p \u3c 0.001), thrombus requiring exchange (0.05 vs. 0.01 EPPY; p = 0.007), cardiac arrhythmia (0.32 vs. 0.24 EPPY; p = 0.04), and infection (0.90 vs. 0.69 EPPY; p = 0.001) compared with high TTR. Two year survival was greater among moderate and high versus low cohorts (Log-rank p = 0.001). The significant reduction in morbidity and mortality in destination therapy (DT) HVAD patients with well-controlled TTR (≥70%) emphasizes the importance of vigilant anticoagulation management

    Two-Year Follow Up of the LATERAL Clinical Trial

    No full text
    BackgroundThe LATERAL trial validated the safety and efficacy of the thoracotomy approach for implantation of the HeartWare HVAD System, leading to Food and Drug Administration approval. We sought to analyze 24-month adverse event (AE) rates, including a temporal analysis of the risk profile, associated with the thoracotomy approach for the HVAD system.MethodsAEs from the LATERAL trial were evaluated over 2 years postimplant. Data was obtained from the Interagency Registry for Mechanically Assisted Circulatory Support database for 144 enrolled United States and Canadian patients. Temporal AE profiles were expressed as events per patient year.ResultsDuring 162.5 patient years of support, there were 25 driveline infections (0.15 events per patient year), 50 gastrointestinal bleeds (0.31 events per patient year), and 21 strokes (0.13 events per patient year). Longitudinal AE analysis at follow-up intervals of <30 and 30 to 180 days, and 6 to 12 and 12 to 24 months revealed the highest AE rate at <30 days, with a decrease in total AEs within the first 6 months. After 6 months, most AE rates either stabilized or decreased through 2 years, including a 95% overall freedom from disabling stroke.ConclusionsTwo-year follow-up of the LATERAL trial revealed a favorable morbidity profile in patients supported with the HVAD system, as AE rates were more likely to occur in the first 30 days postimplant, and overall AE rates were significantly reduced after 6 months. Importantly, 2-year freedom from disabling stroke was 95%. These data further support the improving AE profile of patients on long-term HVAD support. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02268942
    corecore