12 research outputs found

    To Tie or Not to Tie-Over Full-Thickness Skin Grafts in Dermatologic Surgery:A Systematic Review of the Literature

    Get PDF
    BACKGROUND Tie-over dressings are frequently used for skin grafts. Although a dressing is necessary for split-thickness skin grafts, their use in full-thickness skin grafts (FTSGs) is questionable. OBJECTIVE This review was conducted to investigate the influence of different tie overs and dressings on graft take for FTSGs in cutaneous surgery. MATERIALS AND METHODS An electronic database search was performed in MEDLINE, EMBASE, Web of Science, and the Cochrane library. The following search terms and comparable were used: skin transplantation, tie-over, fixation, sutures, and take. RESULTS Fifteen articles met the inclusion criteria. Eight studies describe no use of a tie-over dressing for FTSGs. Dressing types included antibacterial dressings, foam or sponges, and bolsters. The lowest graft take was 80% (with a tie-over dressing). The highest graft take was 100% (with and without a tie-over dressing). CONCLUSION The results show that, regardless of the technique used, the overall graft success rate is high. Although a definite recommendation could not be made, it seems that a graft without a tie-over dressing can suffice in certain circumstances

    Incomplete Excision of Cutaneous Squamous Cell Carcinoma; Systematic Review of the Literature

    Get PDF
    The treatment of choice for cutaneous squamous cell carcinoma is complete surgical excision. Incomplete excision of cutaneous squamous cell carcinoma has an increased risk of local recurrence, deep subclinical progression, and metastasis. This study aimed to investigate the proportion and risk factors of incomplete excised cutaneous squamous cell carcinoma. A systematic review of the literature was performed. Incomplete excision rates for cutaneous squamous cell carcinoma ranged from 0.4% to 35.7%. The pooled incomplete excision risk estimate was 13% (95% confidence interval 9-17%). Risk factors noted in more than one study for incomplete excision included tumor depth and size, type of operator, head and neck localization, and former incomplete excision. We found an overall incomplete excision rate of 13% for cutaneous squamous cell carcinoma. Risk factors should be taken into account in the management of cutaneous squamous cell carcinoma surgical treatment

    Aggressive Squamous Cell Carcinoma in Organ Transplant Recipients

    Get PDF
    Importance: Squamous cell carcinoma (SCC) is the most frequent malignant neoplasm found in solid organ transplant recipients and is associated with a more aggressive disease course and higher risk of metastasis and death than in the general population. Objectives: To report the clinicopathologic features of and identify factors associated with aggressive SCC in solid organ transplant recipients. Methods: This retrospective multicentric case series included 51 patients who underwent solid organ transplantation and were found to have aggressive SCC, defined by nodal or distant metastasis or death by local progression of primary SCC. Standard questionnaires were completed by the researchers between July 18, 2005, and January 1, 2015. Data were analyzed between February 22, 2016, and July 12, 2016. Results: Of the 51 participants, 43 were men and 8 were women, with a median age of 51 years (range, 19-71 years) at time of transplantation and 62 years (range, 36-77 years) at time of diagnosis of aggressive SCC. The distribution of aggressive SCC was preferentially on the face (34 [67%]) and scalp (6 [12%]), followed by the upper extremities (6 [12%]). A total of 21 tumors (41%) were poorly differentiated, with a median tumor diameter of 18.0 mm (range, 4.0-64.0 mm) and median tumor depth of 6.2 mm (range, 1.0-20.0 mm). Perineural invasion was present in 20 patients (39%), while 23 (45%) showed a local recurrence. The 5-year overall survival rate was 23%, while 5-year disease-specific survival was 30.5%. Conclusions and Relevance: Results of this case series suggest that anatomical site, differentiation, tumor diameter, tumor depth, and perineural invasion are important risk factors in aggressive SCC in solid organ transplant recipients

    Dynamic characteristics of skin reaction force in different body postures

    No full text
    Mechanical stress influences scarring of a surgical wound. Several lines have been proposed for the best excision direction. It is unknown if these lines still apply when the body posture changes. The objective is to measure the skin reaction force in four directions and determine the direction of least force. Secondary objective is to determine if the reaction force varies in a different body posture. Skin reaction force was measured with the compressiometer in 30 participants on four different locations (forearm/upper arm/shoulder blade/lower back) in four directions (0°–45°–90°–135°) and two body postures. The direction of least skin reaction force changed with a different body posture and was significant for the forearm (p &lt; 0.01) and shoulder blade (p = 0.05) The skin reaction force in all four direction changed significantly in a different body posture, except the 45° line in the upper arm and shoulder blade. Our results demonstrate that the skin reaction force in four directions in four locations varies with change in body posture. Focus should therefore not only lay on choosing the right direction, but also on managing skin tension postoperatively.</p

    The Compressiometer: Towards a new skin tensiometer for research and surgical planning

    No full text
    After surgery, around 35% of patients experience problems of excessive scarring, causing disfiguring and impaired function. An incision placed in the wrong direction causes unnecessary skin tension on the wound, resulting in increased collagen disposition and potentially hypertrophic scars. Currently, skin tension lines are used for incision planning. However, these lines are not universal and are a static representation of the skin tension that is in fact under influence of muscle action. By designing a new skin force measurement device the authors intend to make research on dynamic skin characteristics possible and to objectify incision planning and excision closure planning. The device applies a known compressive force to the skin in standardized directions and measures the displacement of the skin. This allows users to measure the skin reaction force in response to compression and to determine the optimal incision line or best wound closure direction. The device has an accuracy of 96% and a sensitivity of &lt; 0.01 mm. It is compact, works non-invasively and standardizes measurement directions and is therefore an improvement over previously designed skin tensiometers.Medical Instruments & Bio-Inspired Technolog

    Measuring Forces in Suture Techniques for Wound Closure

    Get PDF
    Background: The use of sutures remains the first choice for wound closure. However, incorrect use of a suture technique can lead to impaired healing. Many techniques are described for high-tension wounds, but not much is known about their mechanical properties. Complications of excessive tension include dehiscence, infection, and ischemic necrosis and could be prevented. This study aimed to compare forces in five techniques (single, horizontal mattress, vertical mattress, pulley, and modified pulley suture) in a standardized wound tension model. Materials and methods: A standardized neoprene wound model was developed on the ForceTRAP system (MediShield B.V., Delft, The Netherlands) to mimic a 5 Newton (N) wound. Five different suture techniques were each repeated 10 times by a student, resident dermatology, and dermsurgeon. The pulling force of the suture's first throw was measured with the Hook-in-Force sensor (Technical University Delft, The Netherlands). Changes in wound tension were measured by the ForceTRAP system. The ForceTRAP is a platform measuring forces from 0 to 20 N in three dimensions with an accuracy of 0.1 N. The Hook-in-Force is a force sensor measuring 0-15 N with an accuracy of 0.5 N. Maximum and mean forces were calculated for each suture technique and operator. Results: Mean maximum pulling force: 5.69 N (standard deviation [SD], 0.88) single, 7.25 N (SD, 1.33) vertical mattress, 8.11 N (SD, 1.00) horizontal mattress, 3.46 N (SD, 0.61) pulley, and 4.52 N (SD, 0.67) modified pulley suture. The mean force increase on the skin (substitute) ranged between 0.80 N (pulley) and 0.96 N (vertical mattress). Conclusions: The pulley suture requires less pulling force compared with other techniques. The mechanical properties of sutures should be taken in consideration when choosing a technique to close wounds.Medical Instruments & Bio-Inspired Technolog

    Dynamic characteristics of skin reaction force in different body postures

    No full text
    Mechanical stress influences scarring of a surgical wound. Several lines have been proposed for the best excision direction. It is unknown if these lines still apply when the body posture changes. The objective is to measure the skin reaction force in four directions and determine the direction of least force. Secondary objective is to determine if the reaction force varies in a different body posture. Skin reaction force was measured with the compressiometer in 30 participants on four different locations (forearm/upper arm/shoulder blade/lower back) in four directions (0°–45°–90°–135°) and two body postures. The direction of least skin reaction force changed with a different body posture and was significant for the forearm (p &lt; 0.01) and shoulder blade (p = 0.05) The skin reaction force in all four direction changed significantly in a different body posture, except the 45° line in the upper arm and shoulder blade. Our results demonstrate that the skin reaction force in four directions in four locations varies with change in body posture. Focus should therefore not only lay on choosing the right direction, but also on managing skin tension postoperatively.Medical Instruments & Bio-Inspired Technolog

    HLA expression as a risk factor for metastases of cutaneous squamous-cell carcinoma in organ- transplant recipients

    Get PDF
    Background: Solid organ-transplant recipients (SOTR) have an increased risk of cutaneous squamous-cell carcinoma (cSCC), metastasis and death from cSCC. In immunocompetent patients with mucosal SCC, downregulation of HLA class I is associated with poor prognosis. Since the degree of HLA expression on tumor cells could play a role in immunogenicity and pathophysiology of cSCC metastasis, we hypothesized that decreased HLA expression is associated with an increased risk of metastasis. Methods: We compared HLA expression between primary metastasized cSCCs, their metastases, and non-metastasized cSCCs from the same patients. Samples were stained for HLA-A, HLA-B/-C and quantified by calculating the difference in immunoreactivity score (IRS) of the primary cSCC compared with all non-metastasized cSCCs. Results: The mean IRS score for HLA-B/C expression was 2.07 point higher in metastasized compared to non-metastasized cSCCs (p = 0.065, 95 % CI −0.18–4.32). 83.3 % of the primary metastasized cSCCs had an IRS score of 4 or higher, compared to 42.9 % in non-metastasized cSCCs. Moderately to poorly differentiated cSCCs had more HLA class I expression compared to well-differentiated cSCCs. Conclusion: Contrary to immunocompetent patients, HLA-B/C expression tends to be upregulated in metastasized cSCC compared to non-metastasized cSCC in SOTR, suggesting that different tumor escape mechanisms play a role in SOTR compared to immunocompetent patients
    corecore