2,778 research outputs found

    A different glance to the site testing above Dome C

    Full text link
    Due to the recent interest shown by astronomers towards the Antarctic Plateau as a potential site for large astronomical facilities, we assisted in the last years to a strengthening of site testing activities in this region, particularly at Dome C. Most of the results collected so far concern meteorologic parameters and optical turbulence measurements based on different principles using different instruments. At present we have several elements indicating that, above the first 20-30 meters, the quality of the optical turbulence above Dome C is better than above whatever other site in the world. The challenging question, crucial to know which kind of facilities to build on, is to establish how much better the Dome C is than a mid-latitude site. In this contribution we will provide some complementary elements and strategies of analysis aiming to answer to this question. We will try to concentrate the attention on critical points, i.e. open questions that still require explanation/attention.Comment: 3 figures, EAS Publications Series, Volume 25, 2007, pp.5

    Parameter Identification of Pressure Sensors by Static and Dynamic Measurements

    Get PDF
    Fast identification methods of pressure sensors are investigated. With regard to a complete accurate sensor parameter identification two different measurement methods are combined. The approach consists on one hand in performing static measurements - an applied pressure results in a membrane deformation measured interferometrically and the corresponding output voltage. On the other hand optical measurements of the modal responses of the sensor membranes are performed. This information is used in an inverse identification algorithm to identify geometrical and material parameters based on a FE model. The number of parameters to be identified is thereby generally limited only by the number of measurable modal frequencies. A quantitative evaluation of the identification results permits furthermore the classification of processing errors like etching errors. Algorithms and identification results for membrane thickness, intrinsic stress and output voltage will be discussed in this contribution on the basis of the parameter identification of relative pressure sensors.Comment: Submitted on behalf of EDA Publishing Association (http://irevues.inist.fr/EDA-Publishing

    Diagnosis of Metal Hypersensitivity in Total Knee Arthroplasty: A Case Report

    Get PDF
    Delayed type hypersensitivity (DTH) reactions are considered infrequent complications in arthroplasty, but have been recognized to be associated with devastating morbidity and substantial decrease in quality of life of affected patients. Chronic inflammation of artificial joints and associated loss of peri-implant bone often require revision surgery. Methods for the diagnosis of implant-related DTH are available but infrequently considered to the full extent. Sequential diagnostics based on exclusion of septic complications, local and systemic metal level determination, lymphocyte transformation testing (LTT), and local T cell subset analysis are required for an unequivocal DTH diagnosis. Here, we report on a patient with a history of chronic rheumatoid arthritis and an unfavorable outcome of unilateral knee arthroplasty. This case illustrates pitfalls and difficulties in the course of recurrent inflammation following joint replacement. In the early course, suspicion of low-grade bacterial infection led to three two-stage revisions. Afterwards, the joint was proven to be sterile. However, metal level quantification revealed release of especially cobalt and chromium from the joint, LTT indicated persisting cobalt and nickel sensitization and subset analysis of T cells from the synovium suggested DTH as a root cause for the inflammatory symptoms. This report aims to recommend the depicted diagnostic algorithm as an adequate tool for future DTH detection. Yet, systemic to local subset ratios for effector memory and regulatory T cells should be derived from sufficient patient numbers to establish it as a diagnostic marker. Moreover, future prospects regarding implant-related DTH diagnostics are discussed. Therapeutic options for the portrayed patient are proposed, considering pharmaceutical, cell-therapeutic and surgical aspects. Patients who experience peri-implant inflammation but do not have obvious mechanical or infectious problems remain a diagnostic challenge and are at high risk of being treated inadequately. Since potentially sensitizing materials are regularly used in arthroplasty, it is essential to detect cases of acute DTH-derived inflammation of an artificial joint at early postoperative stages. This would reduce the severity of inflammation-related long-term consequences for affected patients and may avoid unnecessary revision surgery

    Immunity to MHC class I antigen after direct DNA transfer into skeletal muscle.

    Get PDF
    Plasmid cDNA encoding the alpha-chain of either membrane-bound (pcRT.45) or secreted (pcRQ.B3) RT1Aa MHC class I Ag were transferred to Lewis (RT1(1)) rat skeletal muscle by direct injection. Rats were challenged 7 days later with an ACI (RT1a) heterotropic heart transplant, and cardiac allograft survival, RT1Aa-specific antibody levels, and frequency of ACI-specific CTL were monitored. Graft rejection was accelerated by > or = 2 days in an Ag-specific and dose-dependent manner in pcRT.45-injected rats. The pcRQ.B3-injected rats also rejected grafts more rapidly; however, graft rejection was accelerated by only 1 day, and graft infiltrates were less pronounced than in pcRT.45-injected rats. Injection of pcRT.45 resulted in an increase in ACI-specific CTL precursor frequency 3 days post-transplant, whereas there was no significant change in rats pretreated with pcRQ.B3 injection. Compared with rats injected with a control plasmid encoding firefly luciferase, transfer of pcRT.45 resulted in an increase in RT1Aa-specific IgG and IgM antibody 3 days after heart transplantation. Transfer of pcRQ.B3 resulted in a similar mean increase in RT1Aa-specific IgG and IgM antibody after transplantation, but the variability from rat to rat was greater, with some animals exhibiting strong priming, and others showing little or no priming by gene injection. Our results suggest that skeletal muscle can express either membrane-bound or secreted MHC class I Ag after gene transfer, but that the membrane-bound form is more immunogenic than the secreted form in the high responder Lewis rat. Direct DNA transfer to skeletal muscle provides a rapid and specific approach to studying immunity to allogeneic MHC Ag

    Use of donor serum to prevent passive transfer of hyperacute rejection

    Get PDF
    Organ transplantation in presensitized recipients continues to be contraindicated for heart and kidney recipients due to the risk of hyperacute rejection, which has no known treatment at this time. We tested whether donor serum, which contains soluble MHC class I antigen, is able to neutralize the effect of anti-donor antibody in the recipient and prevent hyperacute or accelerated rejection. A rat model of passive immunization was used to test the role of anti-donor antibody in hyperacute rejection. Seven of 10 recipients of hyperimmune serum (HyS), derived from Lewis rats (RT1l) following 3 ACI (RT1a) skin grafts, developed hyperacute or accelerated rejection. Intravenous injection of ACI serum prior to the HyS administration prevented hyperacute rejection in all recipients tested. When third-party (Wistar-Furth, RT1u) serum was given to Lewis rats injected with HyS, hyperacute rejection was not abrogated. When examining the mechanism of this effect, a simple antibody blocking phenomenon was found to be unlikely since flow cytometry analysis showed that ACI serum needed to be present at > or = 256-fold excess compared to HyS to block anti-ACI antibody binding to RT1.Aa+cells by 50%. We tested whether the RT1.Aa class I antigen in ACI serum had other biologic properties that resulted in the prolonged graft survival. However, removal of RT1.Aa antigen from ACI serum prior to use in the passive transfer model did not abrogate the graft prolongation observed previously. These data suggest that components of donor serum other than MHC class I antigen may be useful for preventing the antibody-mediated component of hyperacute rejection

    Induction of specific tolerance by intrathymic injection of recipient muscle cells transfected with donor class I major histocompatibility complex.

    Get PDF
    Induction of tolerance to allogeneic MHC antigens has been a goal in the field of transplantation because it would reduce or eliminate the need for generalized immunosuppression. Although encouraging results have been obtained in experimental models by exposing recipient thymus to donor cells before transplantation, donor cells are not typically available at that time, and the donor antigens responsible for the effect are poorly defined. In the present study, thymic tolerance was demonstrated without using donor cells. Recipient thymus was injected before transplantation with autologous myoblasts and myotubes that were genetically modified to express allogeneic donor-type MHC class I antigen. Donor-specific unresponsiveness was induced to a completely MHC-disparate liver transplant and to a subsequent donor-type cardiac allograft, but not a third-party allograft. In vitro, recipient CTL demonstrated a 10-fold reduction in killing of donor cells, but not of third-party cells. Our results demonstrate: (1) that recipient muscle cells can be genetically engineered to induce donor-specific unresponsiveness when given intrathymically, and (2) transfected recipient cells expressing only donor MHC class I antigen can induce tolerance to a fully allogeneic donor

    Two-stage coarsening mechanism in a kinetically constrained model of an attractive colloid

    Full text link
    We study an attractive version of the East model using the real-space renormalization group (RG) introduced by Stella et al. The former is a kinetically constrained model with an Ising-like interaction between excitations, and shows striking agreement with the phenomonology of attractive colloidal systems. We find that the RG predicts two nonuniversal dynamic exponents, which suggests that in the out-of-equilibrium regime the model coarsens via a two-stage mechanism. We explain this mechanism physically, and verify this prediction numerically. In addition, we find that the characteristic relaxation time of the model is a non-monotonic function of attraction strength, again in agreement with numerical results.Comment: 10 page
    corecore