3 research outputs found

    Biomechanical evaluation of combined short segment fixation and augmentation of incomplete osteoporotic burst fractures

    Full text link
    Background: Treating traumatic fractures in osteoporosis is challenging. Multiple clinical treatment options are found in literature. Augmentation techniques are promising to reduce treatment-related morbidity. In recent years, there have been an increasing number of reports about extended indication for augmentation techniques. However, biomechanical evaluations of these techniques are limited. Methods: Nine thoracolumbar osteoporotic spinal samples (4 FSU) were harvested from postmortem donors and immediately frozen. Biomechanical testing was performed by a robotic-based spine tester. Standardized incomplete burst fractures were created by a combination of osteotomy-like weakening and high velocity compression using a hydraulic material testing apparatus. Biomechanical measurements were performed on specimens in the following conditions: 1) intact, 2) fractured, 3) bisegmental instrumented, 4) bisegmental instrumented with vertebroplasty (hybrid augmentation, HA) and 5) stand-alone vertebroplasty (VP). The range of motion (RoM), neutral zone (NZ), elastic zone (EZ) and stiffness parameters were determined. Statistical evaluation was performed using Wilcoxon signed-rank test for paired samples (p = 0.05). Results: Significant increases in RoM and in the NZ and EZ (p < 0.005) were observed after fracture production. The RoM was decreased significantly by applying the dorsal bisegmental instrumentation to the fractured specimens (p < 0.005). VP reduced fractured RoM in flexion but was still increased significantly (p < 0.05) above intact kinematic values. NZ stiffness (p < 0.05) and EZ stiffness (p < 0.01) was increased by VP but remained lower than prefracture values. The combination of short segment instrumentation and vertebroplasty (HA) showed no significant changes in RoM and stiffness in NZ in comparison to the instrumented group, except for significant increase of EZ stiffness in flexion (p < 0.05). Conclusions: Stand-alone vertebroplasty (VP) showed some degree of support of the anterior column but was accompanied by persistent traumatic instability. Therefore, we would advocate against using VP as a stand-alone procedure in traumatic fractures. HA did not increase primary stability of short segment instrumentation. Some additional support of anterior column and changes of kinematic values of the EZ may lead one to suppose that additive augmentation may reduce the load of dorsal implants and possibly reduce the risk of implant failure.<br

    Experimentally induced incomplete burst fractures - a novel technique for calf and human specimens

    Full text link
    Background: Fracture morphology is crucial for the clinical decision-making process preceding spinal fracture treatment. The presented experimental approach was designed in order to ensure reproducibility of induced fracture morphology. Results: The presented method resulted in fracture morphology, found in clinical classification systems like the Magerl classification. In the calf spine samples, 70% displayed incomplete burst fractures corresponding to type A3.1 and A3.2 fractures. In all human samples, superior incomplete burst fractures (Magerl A3.1) were identified by an independent radiologist and spine surgeon. Conclusions: The presented set up enables the first experimental means to reliably model and study distinct incomplete burst fracture patterns in an in vitro setting. Thus, we envisage this protocol to facilitate further studies on spine fracture treatment of incomplete burst fractures

    Complex biomechanical properties of non-augmented and augmented pedicle screws in human vertebrae with reduced bone density

    Full text link
    Background: In osteoporotic bone, the quality of the bone-to-implant interface is decreased, which may lead to early implant failure. Screw anchorage can be improved by augmentation. This effect is mainly investigated with a pull-out test. To our knowledge, the effect of cement augmentation in an in vivo physiological setup focusing on screw movement has not been investigated to date. The aim of this work was to investigate and compare augmented and native screw behavior in a physiologically related setup. Methods: Twelve fresh-frozen human lumbar vertebrae were divided into two groups. Each vertebra was bilaterally instrumented with either non-augmented or augmented pedicle screw systems and loaded in a recently developed test setup that provided cyclic conditions comparable to a physiological gait. The cyclic loading should test the primary implant stability, comparable to the postoperative period of two months in a worst-case scenario in the absence of osseous remodeling. Screws were tracked optically, and screw movement and failure patterns were observed. Results: Mutual influence between the left and right sides resulted in a successive, rather than simultaneous, failure. Augmentation of the screws in vertebrae with poor bone quality reduced screw subsidence and thus improved the rigidity of the screw-to-implant interface by up to six-fold. The non-augmented condition was significantly related to early screw failure. Conclusions: Pedicle screw system failure involves a complex bilateral-coupled mechanism. The cyclic loading based on physiological conditions during walking has allowed the postoperative conditions and clinical failure mechanisms to be simulated in vitro and clarified. Future implant systems should be investigated with a physiologically related setup
    corecore